5 resultados para Foucauldian analysis, photovoice, power, representation, decolonizing youth work

em Digital Commons - Michigan Tech


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project consists of a proposed curriculum for a semester-long, community-based workshop for LGBTQIA+ (lesbian, gay, bisexual, trans*, queer or questioning, intersex, asexual or ally, "+" indicating other identifications that deviate from heterosexual) youth ages 16-18. The workshop focuses on an exploration of LGBTQIA+ identity and community through discussion and collaborative rhetorical analysis of visual and social media. Informed by queer theory and history, studies on youth work, and visual media studies and incorporating rhetorical criticism as well as liberatory pedagogy and community literacy practices, the participation-based design of the workshop seeks to involve participants in selection of media texts, active analytical viewership, and multimodal response. The workshop is designed to engage participants in reflection on questions of individual and collective responsibility and agency as members and allies of various communities. The goal of the workshop is to strengthen participants' abilities to analyze the complex ways in which television, film, and social media influence their own and others’ perceptions of issues surrounding queer identities. As part of the reflective process, participants are challenged to consider how they can in turn actively and collaboratively respond to and potentially help to shape these perceptions. My project report details the theoretical framework, pedagogical rationale, methods of text selection and critical analysis, and guidelines for conduct that inform and structure the workshop.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This document will demonstrate the methodology used to create an energy and conductance based model for power electronic converters. The work is intended to be a replacement for voltage and current based models which have limited applicability to the network nodal equations. Using conductance-based modeling allows direct application of load differential equations to the bus admittance matrix (Y-bus) with a unified approach. When applied directly to the Y-bus, the system becomes much easier to simulate since the state variables do not need to be transformed. The proposed transformation applies to loads, sources, and energy storage systems and is useful for DC microgrids. Transformed state models of a complete microgrid are compared to experimental results and show the models accurately reflect the system dynamic behavior.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in information technology and global data availability have opened the door for assessments of sustainable development at a truly macro scale. It is now fairly easy to conduct a study of sustainability using the entire planet as the unit of analysis; this is precisely what this work set out to accomplish. The study began by examining some of the best known composite indicator frameworks developed to measure sustainability at the country level today. Most of these were found to value human development factors and a clean local environment, but to gravely overlook consumption of (remote) resources in relation to nature’s capacity to renew them, a basic requirement for a sustainable state. Thus, a new measuring standard is proposed, based on the Global Sustainability Quadrant approach. In a two‐dimensional plot of nations’ Human Development Index (HDI) vs. their Ecological Footprint (EF) per capita, the Sustainability Quadrant is defined by the area where both dimensions satisfy the minimum conditions of sustainable development: an HDI score above 0.8 (considered ‘high’ human development), and an EF below the fair Earth‐share of 2.063 global hectares per person. After developing methods to identify those countries that are closest to the Quadrant in the present‐day and, most importantly, those that are moving towards it over time, the study tackled the question: what indicators of performance set these countries apart? To answer this, an analysis of raw data, covering a wide array of environmental, social, economic, and governance performance metrics, was undertaken. The analysis used country rank lists for each individual metric and compared them, using the Pearson Product Moment Correlation function, to the rank lists generated by the proximity/movement relative to the Quadrant measuring methods. The analysis yielded a list of metrics which are, with a high degree of statistical significance, associated with proximity to – and movement towards – the Quadrant; most notably: Favorable for sustainable development: use of contraception, high life expectancy, high literacy rate, and urbanization. Unfavorable for sustainable development: high GDP per capita, high language diversity, high energy consumption, and high meat consumption. A momentary gain, but a burden in the long‐run: high carbon footprint and debt. These results could serve as a solid stepping stone for the development of more reliable composite index frameworks for assessing countries’ sustainability.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

It is an important and difficult challenge to protect modern interconnected power system from blackouts. Applying advanced power system protection techniques and increasing power system stability are ways to improve the reliability and security of power systems. Phasor-domain software packages such as Power System Simulator for Engineers (PSS/E) can be used to study large power systems but cannot be used for transient analysis. In order to observe both power system stability and transient behavior of the system during disturbances, modeling has to be done in the time-domain. This work focuses on modeling of power systems and various control systems in the Alternative Transients Program (ATP). ATP is a time-domain power system modeling software in which all the power system components can be modeled in detail. Models are implemented with attention to component representation and parameters. The synchronous machine model includes the saturation characteristics and control interface. Transient Analysis Control System is used to model the excitation control system, power system stabilizer and the turbine governor system of the synchronous machine. Several base cases of a single machine system are modeled and benchmarked against PSS/E. A two area system is modeled and inter-area and intra-area oscillations are observed. The two area system is reduced to a two machine system using reduced dynamic equivalencing. The original and the reduced systems are benchmarked against PSS/E. This work also includes the simulation of single-pole tripping using one of the base case models. Advantages of single-pole tripping and comparison of system behavior against three-pole tripping are studied. Results indicate that the built-in control system models in PSS/E can be effectively reproduced in ATP. The benchmarked models correctly simulate the power system dynamics. The successful implementation of a dynamically reduced system in ATP shows promise for studying a small sub-system of a large system without losing the dynamic behaviors. Other aspects such as relaying can be investigated using the benchmarked models. It is expected that this work will provide guidance in modeling different control systems for the synchronous machine and in representing dynamic equivalents of large power systems.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The electric utility business is an inherently dangerous area to work in with employees exposed to many potential hazards daily. One such hazard is an arc flash. An arc flash is a rapid release of energy, referred to as incident energy, caused by an electric arc. Due to the random nature and occurrence of an arc flash, one can only prepare and minimize the extent of harm to themself, other employees and damage to equipment due to such a violent event. Effective January 1, 2009 the National Electric Safety Code (NESC) requires that an arc-flash assessment be performed by companies whose employees work on or near energized equipment to determine the potential exposure to an electric arc. To comply with the NESC requirement, Minnesota Power’s (MP’s) current short circuit and relay coordination software package, ASPEN OneLinerTM and one of the first software packages to implement an arc-flash module, is used to conduct an arc-flash hazard analysis. At the same time, the package is benchmarked against equations provided in the IEEE Std. 1584-2002 and ultimately used to determine the incident energy levels on the MP transmission system. This report goes into the depth of the history of arc-flash hazards, analysis methods, both software and empirical derived equations, issues of concern with calculation methods and the work conducted at MP. This work also produced two offline software products to conduct and verify an offline arc-flash hazard analysis.