2 resultados para Fine dining restaurants
em Digital Commons - Michigan Tech
Resumo:
Universities in the United States are applying more sustainable approaches to their dining service operations. "The increase in social consciousness and environmental stewardship on college campuses has spurred an array of new and innovative sustainability programs"(ARAMARK Higher Education 2008). University residence dining is typically cafeteria style, with students using trays to carry food. Studies report that food served without trays substantially reduces food waste and water and electrical consumption associated with washing trays. Commonly, these reported results are estimates and not measurements taken under actual operating conditions. This study utilizes measurements recorded under actual dining service conditions in student residence halls at Michigan Technological University to develop the following: 1) operational-specific data on the issues and potential savings associated with a conversion to trayless dining and 2) life cycle assessment (LCA) cost and environmental impact analyses comparing dining with and without trays. For the LCA, the entire life cycle of the system is considered, from the manufacturing to the usage and disposal phases. The study shows that trayless dining reduces food waste because diners carry less food. The total savings for the diner shifts when not using trays for the standard academic year (205 days), with an average number of 700 diners, is 7,032 pounds of food waste from the pre-rinse area (33% reduction) and 3,157 pounds of food waste from the pan washing area (39% reduction). In addition, for each day of the study, the diners consumed more food during the trayless portion of the experiment. One possible explanation for the increased food consumption during this short duration study could be that the diners found it more convenient to eat the extra food on their plate rather than carrying it back for disposal. The trayless dining experiment shows a reduction in dishwasher water, steam, and electrical consumption for each day of the study. The average reduction of dishwasher water, steam, and electrical consumption over the duration of the study were 10.7%, 9.5%, and 6.4% respectively. Trayless dining implementation would result in a decrease of 4,305 gallons of consumption and wastewater discharge, 2.87 mm BTU of steam consumption, and 158 kWh of electrical consumption for the dinner shift over the academic year. Results of the LCA indicate a total savings of $190.4 when trays are not used during the dinner shift. Trayless dining requires zero CO2 eq and cumulative energy demand in the manufacturing stage, reductions of 1005 kg CO2 eq and 861 MJ eq in the usage phase, and reductions of 6458 kg CO2 eq and 1821 MJ eq in the end of the life cycle.
Resumo:
This study investigates the compressive properties of concrete incorporating Mature Fine Tailings (MFTs) waste stream from a tar sands mining operation. The objectives of this study are to investigate material properties of the MFT material itself, as well as establish general feasibility of the utilization of MFT material in concrete mixtures through empirical data and visual observations. Investigations undertaken in this study consist of moisture content, materials finer than No. 200 sieve, Atterburg Limits as well as visual observations performed on MFT material as obtained. Control concrete mixtures as well as MFT replacement mixture designs (% by wt. of water) were guided by properties of the MFT material that were experimentally established. The experimental design consists of compression testing of 4”-diameter concrete cylinders of a control mixture, 30% MFT, 50% MFT and 70% MFT replacement mixtures with air-entrainer additive, as well as a control mixture and 30% MFT replacement mixture with no air-entrainer. A total of 6 mixtures (2 control mixtures, 4 replacement mixtures) moist-cured in lime water after 24 hours initial curing were tested for ultimate compressive strength at 7 days and 28 days in accordance to ASTM C39. The test results of fresh concrete material show that the addition of air-entrainer to the control mixture increases slump from 4” to 5.5”. However, the use of MFT material in concrete mixtures significantly decreases slump as compared to controls. All MFT replacement mixtures (30%, 50%, and 70%) with air-entrainer present slumps of 1”. 30% MFT with no air-entrainer presents a slump of 1.5”. It was found that 7-day ultimate compressive stress was not a good predictor of 28-day ultimate compressive stress. 28-day results indicate that the use of MFT material in concrete with air-entrainer decreases ultimate compressive stress for 30%, 50% and 70% MFT replacement amounts by 14.2%, 17.3% and 25.1% respectively.