4 resultados para Coal compositions
em Digital Commons - Michigan Tech
Resumo:
In 1906, two American industrialists, John Munroe Longyear and Frederick Ayer, formed the Arctic Coal Company to make the first large scale attempt at mining in the high-Arctic location of Spitsbergen, north of the Norwegian mainland. In doing so, they encountered numerous obstacles and built an organization that attempted to overcome them. The Americans sold out in 1916 but others followed, eventually culminating in the transformation of a largely underdeveloped landscape into a mining region. This work uses John Law’s network approach of the Actor Network Theory (ANT) framework to explain how the Arctic Coal Company built a mining network in this environmentally difficult region and why they made the choices they did. It does so by identifying and analyzing the problems the company encountered and the strategies they used to overcome them by focusing on three major components of the operations; the company’s four land claims, its technical system and its main settlement, Longyear City. Extensive comparison between aspects of Longyear City and the company’s choices of technology with other American examples place analysis of the company in a wider context and helps isolate unique aspects of mining in the high-Arctic. American examples dominate comparative sections because Americans dominated the ownership and upper management of the company.
Resumo:
Following the rapid growth of China's economy, energy consumption, especially electricity consumption of China, has made a huge increase in the past 30 years. Since China has been using coal as the major energy source to produce electricity during these years, environmental problems have become more and more serious. The research question for this paper is: "Can China use alternative energies instead of coal to produce more electricity in 2030?" Hydro power, nuclear power, natural gas, wind power and solar power are considered as the possible and most popular alternative energies for the current situation of China. To answer the research question above, there are two things to know: How much is the total electricity consumption in China by 2030? And how much electricity can the alternative energies provide in China by 2030? For a more reliable forecast, an econometric model using the Ordinary Least Squares Method is established on this paper to predict the total electricity consumption by 2030. The predicted electricity coming from alternative energy sources by 2030 in China can be calculated from the existing literature. The research results of this paper are analyzed under a reference scenario and a max tech scenario. In the reference scenario, the combination of the alternative energies can provide 47.71% of the total electricity consumption by 2030. In the max tech scenario, it provides 57.96% of the total electricity consumption by 2030. These results are important not only because they indicate the government's long term goal is reachable, but also implies that the natural environment of China could have an inspiring future.
Resumo:
This dissertation established a standard foam index: the absolute foam index test. This test characterized a wide range of coal fly ash by the absolute volume of air-entraining admixture (AEA) necessary to produce a 15-second metastable foam in a coal fly ash-cement slurry in a specified time. The absolute foam index test was used to characterize fly ash samples having loss on ignition (LOI) values that ranged from 0.17 to 23.3 %wt. The absolute foam index characterized the fly ash samples by absolute volume of AEA, defined as the amount of undiluted AEA solution added to obtain a 15-minute endpoint signified by 15-second metastable foam. Results were compared from several foam index test time trials that used different initial test concentrations to reach termination at selected times. Based on the coefficient of variation (CV), a 15-minute endpoint, with limits of 12 to 18 minutes was chosen. Various initial test concentrations were used to accomplish consistent contact times and concentration gradients for the 15-minute test endpoint for the fly ash samples. A set of four standard concentrations for the absolute foam index test were defined by regression analyses and a procedure simplifying the test process. The set of standard concentrations for the absolute foam index test was determined by analyzing experimental results of 80 tests on coal fly ashes with loss on ignition (LOI) values ranging from 0.39 to 23.3 wt.%. A regression analysis informed selection of four concentrations (2, 6, 10, and 15 vol.% AEA) that are expected to accommodate fly ashes with 0.39 to 23.3 wt.% LOI, depending on the AEA type. Higher concentrations should be used for high-LOI fly ash when necessary. A procedure developed using these standard concentrations is expected to require only 1-3 trials to meet specified endpoint criteria for most fly ashes. The AEA solution concentration that achieved the metastable foam in the foam index test was compared to the AEA equilibrium concentration obtained from the direct adsorption isotherm test with the same fly ash. The results showed that the AEA concentration that satisfied the absolute foam index test was much less than the equilibrium concentration. This indicated that the absolute foam index test was not at or near equilibrium. Rather, it was a dynamic test where the time of the test played an important role in the results. Even though the absolute foam index was not an equilibrium condition, a correlation was made between the absolute foam index and adsorption isotherms. Equilibrium isotherm equations obtained from direct isotherm tests were used to calculate the equilibrium concentrations and capacities of fly ash from 0.17 to 10.5% LOI. The results showed that the calculated fly ash capacity was much less than capacities obtained from isotherm tests that were conducted with higher initial concentrations. This indicated that the absolute foam index was not equilibrium. Rather, the test is dynamic where the time of the test played an important role in the results. Even though the absolute foam index was not an equilibrium condition, a correlation was made between the absolute foam index and adsorption isotherms for fly ash of 0.17 to 10.5% LOI. Several batches of mortars were mixed for the same fly ash type increasing only the AEA concentration (dosage) in each subsequent batch. Mortar air test results for each batch showed for each increase in AEA concentration, air contents increased until a point where the next increase in AEA concentration resulted in no increase in air content. This was maximum air content that could be achieved by the particular mortar system; the system reached its air capacity at the saturation limit. This concentration of AEA was compared to the critical micelle concentration (CMC) for the AEA and the absolute foam index.
Resumo:
The purpose of this thesis is to analyze the evolution of an early 20th century mining system in Spitsbergen as applied by Boston-based Arctic Coal Company (ACC). This analysis will address the following questions: Did the system evolve in a linear, technological-based fashion? Or was the progression more a product of interactions and negotiations with the natural and human landscapes present during the time of occupation? Answers to these questions will be sought through review of historical records and material residues identified during the 2008 field examination on Spitsbergen. The Arctic Coal Company’s flagship mine, ACC Mine No. 1, will serve as the focus for this analysis. The mine was the company’s largest undertaking during its occupation of Longyear Valley and today exhibits a large collection of related features and artifacts. The study will emphasize on the material record within an analysis of technical, environmental and social influences that guided the course of the mining system. The intent of this thesis is a better understanding of how a particular resource extraction industry took root in the Arctic.