6 resultados para time resolved Kerr rotation measurement
em Bucknell University Digital Commons - Pensilvania - USA
Resumo:
As the number of solutions to the Einstein equations with realistic matter sources that admit closed time-like curves (CTC's) has grown drastically, it has provoked some authors [10] to call for a physical interpretation of these seemingly exotic curves that could possibly allow for causality violations. A first step in drafting a physical interpretation would be to understand how CTC's are created because the recent work of [16] has suggested that, to follow a CTC, observers must counter-rotate with the rotating matter, contrary to the currently accepted explanation that it is due to inertial frame dragging that CTC's are created. The exact link between inertialframe dragging and CTC's is investigated by simulating particle geodesics and the precession of gyroscopes along CTC's and backward in time oriented circular orbits in the van Stockum metric, known to have CTC's that could be traversal, so the van Stockum cylinder could be exploited as a time machine. This study of gyroscopeprecession, in the van Stockum metric, supports the theory that CTC's are produced by inertial frame dragging due to rotating spacetime metrics.
Resumo:
We previously observed that mental manipulation of the pitch level or temporal organization of melodies results in functional activation in the human intraparietal sulcus (IPS), a region also associated with visuospatial transformation and numerical calculation. Two outstanding questions about these musical transformations are whether pitch and time depend on separate or common processing in IPS, and whether IPS recruitment in melodic tasks varies depending upon the degree of transformation required (as it does in mental rotation). In the present study we sought to answer these questions by applying functional magnetic resonance imaging while musicians performed closely matched mental transposition (pitch transformation) and melody reversal (temporal transformation) tasks. A voxel-wise conjunction analysis showed that in individual subjects, both tasks activated overlapping regions in bilateral IPS, suggesting that a common neural substrate subserves both types of mental transformation. Varying the magnitude of mental pitch transposition resulted in variation of IPS BOLD signal in correlation with the musical key-distance of the transposition, but not with the pitch distance, indicating that the cognitive metric relevant for this type of operation is an abstract one, well described by music-theoretic concepts. These findings support a general role for the IPS in systematically transforming auditory stimulus representations in a nonspatial context. (C) 2013 Elsevier Inc. All rights reserved.
Resumo:
Energy transfer between the interacting waves in a distributed Brillouin sensor can result in a distorted measurement of the local Brillouin gain spectrum, leading to systematic errors. It is demonstrated that this depletion effect can be precisely modelled. This has been validated by experimental tests in an excellent quantitative agreement. Strict guidelines can be enunciated from the model to make the impact of depletion negligible, for any type and any length of fiber. (C) 2013 Optical Society of America
Resumo:
Telomere length measurement has been proposed as a promising tool to estimate the age of individuals in natural populations. We used real-time quantitative PCR (qPCR) to measure relative telomere length in four tissues (brain, kidney, liver and muscle) of European hake (Merluccius merluccius) in different groups based upon body length an otolith age estimate. We observed a high level of inter-individual differences in the measurements of relative telomere length in hakes of similar age and body length groups. The results of qPCR analysis showed a great variability in all measures and a lack of repeatability and reproducibility with significant statistical differences in the results of the different assays. The paper discusses the technical reasons for the variability in qPCR obtained in this work and by other authors.
Resumo:
Brain functions, such as learning, orchestrating locomotion, memory recall, and processing information, all require glucose as a source of energy. During these functions, the glucose concentration decreases as the glucose is being consumed by brain cells. By measuring this drop in concentration, it is possible to determine which parts of the brain are used during specific functions and consequently, how much energy the brain requires to complete the function. One way to measure in vivo brain glucose levels is with a microdialysis probe. The drawback of this analytical procedure, as with many steadystate fluid flow systems, is that the probe fluid will not reach equilibrium with the brain fluid. Therefore, brain concentration is inferred by taking samples at multiple inlet glucose concentrations and finding a point of convergence. The goal of this thesis is to create a three-dimensional, time-dependent, finite element representation of the brainprobe system in COMSOL 4.2 that describes the diffusion and convection of glucose. Once validated with experimental results, this model can then be used to test parameters that experiments cannot access. When simulations were run using published values for physical constants (i.e. diffusivities, density and viscosity), the resulting glucose model concentrations were within the error of the experimental data. This verifies that the model is an accurate representation of the physical system. In addition to accurately describing the experimental brain-probe system, the model I created is able to show the validity of zero-net-flux for a given experiment. A useful discovery is that the slope of the zero-net-flux line is dependent on perfusate flow rate and diffusion coefficients, but it is independent of brain glucose concentrations. The model was simplified with the realization that the perfusate is at thermal equilibrium with the brain throughout the active region of the probe. This allowed for the assumption that all model parameters are temperature independent. The time to steady-state for the probe is approximately one minute. However, the signal degrades in the exit tubing due to Taylor dispersion, on the order of two minutes for two meters of tubing. Given an analytical instrument requiring a five μL aliquot, the smallest brain process measurable for this system is 13 minutes.
Resumo:
Research on the physiological adaptation process has found that stress is associated with the rate of cortisol secretion, the main hormone that reflects stress. However, considerable variation among subjects has been reported. Using a sample of older adults (N=46), we tested the hypothesis that cortisol reactivity is composed of (1) a situation-related component representing hypothalamic influence on cortisol secretion observed on three different occasions, and (2) a stable component representing a general trait responsible for cortisol responses observed from occasion to occasion. LISREL VIII was used to test this hypothesis. Results indicated that a homogeneous reliability model was not supported by the data. A congeneric measurement model represented a better fit to the data. Results suggest that subjects have consistent patterns of response during separate experimental occasions. However, results do not suggest a consistent pattern of response over time. The main implication of these results is that salivary cortisol measures are sensitive to experimental stress situations. As such, this noninvasive method may be useful in examining adaptive responses to stress.