3 resultados para score validity

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain functions, such as learning, orchestrating locomotion, memory recall, and processing information, all require glucose as a source of energy. During these functions, the glucose concentration decreases as the glucose is being consumed by brain cells. By measuring this drop in concentration, it is possible to determine which parts of the brain are used during specific functions and consequently, how much energy the brain requires to complete the function. One way to measure in vivo brain glucose levels is with a microdialysis probe. The drawback of this analytical procedure, as with many steadystate fluid flow systems, is that the probe fluid will not reach equilibrium with the brain fluid. Therefore, brain concentration is inferred by taking samples at multiple inlet glucose concentrations and finding a point of convergence. The goal of this thesis is to create a three-dimensional, time-dependent, finite element representation of the brainprobe system in COMSOL 4.2 that describes the diffusion and convection of glucose. Once validated with experimental results, this model can then be used to test parameters that experiments cannot access. When simulations were run using published values for physical constants (i.e. diffusivities, density and viscosity), the resulting glucose model concentrations were within the error of the experimental data. This verifies that the model is an accurate representation of the physical system. In addition to accurately describing the experimental brain-probe system, the model I created is able to show the validity of zero-net-flux for a given experiment. A useful discovery is that the slope of the zero-net-flux line is dependent on perfusate flow rate and diffusion coefficients, but it is independent of brain glucose concentrations. The model was simplified with the realization that the perfusate is at thermal equilibrium with the brain throughout the active region of the probe. This allowed for the assumption that all model parameters are temperature independent. The time to steady-state for the probe is approximately one minute. However, the signal degrades in the exit tubing due to Taylor dispersion, on the order of two minutes for two meters of tubing. Given an analytical instrument requiring a five μL aliquot, the smallest brain process measurable for this system is 13 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short, portable mental status questionnaire (SPMSQ) developed by Pfeiffer has several advantages over previous short instruments designed to assess the intellectual functioning of older adults. It is based upon data from both institutionalized and community-dwelling elderly. Although Pfeiffer a four-group classification, he used to groups in his initial validation study: (a) intact/mildly impaired, and (b) moderately/severely impaired. The present study compared clinicians' ratings with those based upon the SPMSQ scores, and examined the validity of the four-group classification. The sample included 181 subjects from seven intermediate care facilities and nine home-care agencies. All were assessed by the OARS questionnaire, which includes the SPMSQ Three discriminant analyses were performed with three different criteria, for two-group, three-group, and four-group models. Results indicated that the two-group model (intact/mildly impaired and moderately/severely impaired) permitted significant discrimination. The four-group model, however, gave less distinct results. In particular, patients who were mildly intellectually impaired could not be clearly distinguished from those who were intact and from those who were moderately impaired. The three-group model (minimally, moderately, severely impaired) seemed to offer the best compromise between the gross dichotomy of the original two-model system and the less accurate four category system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report outlines the development, validity, and reliability of Part A of the OARS Multidimensional Functional Assessment Questionnaire. Part A permits assessment of individuals' functioning on each of five dimensions (social, economic, mental health, physical health and self-care capacity), the detailed information in each area being summarized on a 6-point rating scale by a rater. Content and consensual validity were ensured by the manner of construction. Information on criterion validity was obtained for all dimensions except social. The criterion used and their associated Kendall's Tau values were: an objective economic scale (.62); ratings based on personal interviews by geropsychiatrists (.60); physician's associates (.82); and physical therapists (.89). For 11 geographically dispersed raters from research and clinic settings, intraclass correlational coefficients, based on 30 subjects, ranged from .66 on physical health to .87 in self-care capacity; 74% of the ratings were in complete agreement, 24% differed by one point.