3 resultados para modulus of deformation

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nanoindentation is a valuable tool for characterization of biomaterials due to its ability to measure local properties in heterogeneous, small or irregularly shaped samples. However, applying nanoindentation to compliant, hydrated biomaterials leads to many challenges including adhesion between the nanoindenter tip and the sample. Although adhesion leads to overestimation of the modulus of compliant samples when analyzing nanoindentation data using traditional analysis techniques, most studies of biomaterials have ignored its effects. This paper demonstrates two methods for managing adhesion in nanoindentation analysis, the nano-JKR force curve method and the surfactant method, through application to two biomedically-relevant compliant materials, poly(dimethyl siloxane) (PDMS) elastomers and poly(ethylene glycol) (PEG) hydrogels. The nano-JKR force curve method accounts for adhesion during data analysis using equations based on the Johnson-Kendall-Roberts (JKR) adhesion model, while the surfactant method eliminates adhesion during data collection, allowing data analysis using traditional techniques. In this study, indents performed in air or water resulted in adhesion between the tip and the sample, while testing the same materials submerged in Optifree Express() contact lens solution eliminated tip-sample adhesion in most samples. Modulus values from the two methods were within 7% of each other, despite different hydration conditions and evidence of adhesion. Using surfactant also did not significantly alter the properties of the tested material, allowed accurate modulus measurements using commercial software, and facilitated nanoindentation testing in fluids. This technique shows promise for more accurate and faster determination of modulus values from nanoindentation of compliant, hydrated biological samples. Copyright 2013 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An outstanding problem in understanding the late Proterozoic tectonic assembly of the southwest is identifying the tectonic setting associated with regional metamorphism at 1.4 Ga. Both isobaric heating and cooling, and counter-clockwise looping PT paths are proposed for this time. We present a study of the Proterozoic metamorphic and deformation history of the Cerro Colorado area, southern Tusas Mountains, New Mexico, which shows that the metamorphism in this area records near-isothermal decompression from 6 to 4 kbar at ca. 1.4 Ga. We do not see evidence for isobaric heating at this time. Decompression from peak pressures is recorded by the reaction Ms + Grt = St + Bt, with a negative slope in PT space; the reaction Ms + Grt = Sil + Bt, which is nearly horizontal in PT space; and partial to total pseudomorphing of kyanite by sillimanite during the main phase of deformation. The clearest reaction texture indicating decompression near peak metamorphic temperature is the replacement of garnet by clots of sillimanite, which are surrounded by halos of biotite. The sillimanite clots, most without relict garnet in the cores and with highly variable aspect ratios, are aligned. They define a lineation that formed with the dominant foliation. An inverted metamorphic gradient is locally defined by sillimanite-garnet schists (625 degrees C) structurally above staurolite-garnet schists (550 degrees C) and implies ductile thrusting during the main phase of deformation. The exhumation that led to the recorded decompression was likely in response to crustal thickening due to ductile thrusting and subsequent denudation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Compliant mechanisms with evenly distributed stresses have better load-bearing ability and larger range of motion than mechanisms with compliance and stresses lumped at flexural hinges. In this paper, we present a metric to quantify how uniformly the strain energy of deformation and thus the stresses are distributed throughout the mechanism topology. The resulting metric is used to optimize cross-sections of conceptual compliant topologies leading to designs with maximal stress distribution. This optimization framework is demonstrated for both single-port mechanisms and single-input single-output mechanisms. It is observed that the optimized designs have lower stresses than their nonoptimized counterparts, which implies an ability for single-port mechanisms to store larger strain energy, and single-input single-output mechanisms to perform larger output work before failure.