2 resultados para common method variance
em Bucknell University Digital Commons - Pensilvania - USA
Resumo:
Parents and children, starting at very young ages, discuss religious and spiritual issues¿where we come from, what happens to us after we die, is there a God, and so on. Unfortunately, few studies have analyzed the content and structure of parent-child conversation about religion and spirituality (Boyatzis & Janicki, 2003; Dollahite & Thatcher, 2009), and most studies have relied on self-report with no direct observation. The current study examined mother-child (M-C) spiritual discourse to learn about its content, structure, and frequency through a survey inventory in combination with direct video observation using a novel structured task. We also analyzed how mothers¿ religiosity along several major dimensions related to their communication behaviors within both methods. Mothers (N = 39, M age = 40) of children aged 3-12 completed a survey packet on M-C spiritual discourse and standard measures of mothers¿ religious fundamentalism, intrinsic religiosity, sanctification of parenting (how much the mother saw herself as doing God¿s work as a parent), and a new measure of parental openness to children¿s spirituality. Then, in a structured task in our lab, mothers (N = 33) and children (M age = 7.33) watched a short film or read a short book that explored death in an age-appropriate manner and then engaged in a videotaped conversation about the movie or book and their religious or spiritual beliefs. Frequency of M-C spiritual discourse was positively related to mothers¿ religious fundamentalism (r = .71, p = .00), intrinsic religiosity (r = .77, p = .00), and sanctification of parenting (r = .79, p = .00), but, surprisingly, was inversely related to mothers¿ v openness to child¿s spirituality (r = -.52, p = .00). Survey data showed that the two most common topics discussed were God (once a week) and religion as it relates to moral issues (once a week). According to mothers their children¿s most common method of initiating spiritual discourse was to repeat what he or she has heard parents or family say about religious issues (M = 2.97; once a week); mothers¿ most common method was to describe their own religious/spiritual beliefs (M = 2.92). Spiritual discourse most commonly occurred either at bedtime or mealtime as reported by 26% of mothers, with the most common triggers reported as daily routine/random thoughts (once a week) and observations of nature (once a week). Mothers¿ most important goals for spiritual discourse were to let their children know that they love them (M = 3.72; very important) and to help them become a good and moral person (M = 3.67; very important). A regression model showed that significant variance in frequency of mother-child spiritual discourse (R2 = .84, p = .00) was predicted by the mothers¿ importance of goals during discourse (ß = 0.46, p = .00), frequency that the mother¿s spirituality was deepened through spiritual discourse (ß = 0.39, p = .00), and the mother¿s fundamentalism (ß = 0.20, p = .05). In a separate regression, the mother¿s comfort in the structured task (ß = 0.70, p = .00), and the number of open-ended questions she asked (ß = -0.26, p = .03) predicted the reciprocity between mother and child (R2 = .62, p = .00). In addition, the mother¿s age (ß = 0.22, p = .059) and comfort during the task (ß = 0.73, p = .00) predicted the child¿s engagement within the structured task. Other findings and theoretical and methodological implications will be discussed.
Resumo:
There are two main types of bone in the human body, trabecular and cortical bone. Cortical bone is primarily found on the outer surface of most bones in the body while trabecular bone is found in vertebrae and at the end of long bones (Ross 2007). Osteoporosis is a condition that compromises the structural integrity of trabecular bone, greatly reducing the ability of the bone to absorb energy from falls. The current method for diagnosing osteoporosis and predicting fracture risk is measurement of bone mineral density. Limitations of this method include dependence on the bone density measurement device and dependence on type of test and measurement location (Rubin 2005). Each year there are approximately 250,000 hip fractures in the United States due to osteoporosis (Kleerekoper 2006). Currently, the most common method for repairing a hip fracture is a hip fixation surgery. During surgery, a temporary guide wire is inserted to guide the permanent screw into place and then removed. It is believed that directly measuring this screw pullout force may result in a better assessment of bone quality than current indirect measurement techniques (T. Bowen 2008-2010, pers. comm.). The objective of this project is to design a device that can measure the force required to extract this guide wire. It is believed that this would give the surgeon a direct, quantitative measurement of bone quality at the site of the fixation. A first generation device was designed by a Bucknell Biomedical Engineering Senior Design team during the 2008- 2009 Academic Year. The first step of this project was to examine the device, conduct a thorough design analysis, and brainstorm new concepts. The concept selected uses a translational screw to extract the guide wire. The device was fabricated and underwent validation testing to ensure that the device was functional and met the required engineering specifications. Two tests were conducted, one to test the functionality of the device by testing if the device gave repeatable results, and the other to test the sensitivity of the device to misalignment. Guide wires were extracted from 3 materials, low density polyethylene, ultra high molecular weight polyethylene, and polypropylene and the force of extraction was measured. During testing, it was discovered that the spring in the device did not have a high enough spring constant to reach the high forces necessary for extracting the wires without excessive deflection of the spring. The test procedure was modified slightly so the wires were not fully threaded into the material. The testing results indicate that there is significant variation in the screw pullout force, up to 30% of the average value. This significant variation was attributed to problems in the testing and data collection, and a revised set of tests was proposed to better evaluate the performance of the device. The fabricated device is a fully-functioning prototype and further refinements and testing of the device may lead to a 3rd generation version capable of measuring the screw pullout force during hip fixation surgery.