2 resultados para Three-dimensional modeling

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dimensional modeling, GT-Power in particular, has been used for two related purposes-to quantify and understand the inaccuracies of transient engine flow estimates that cause transient smoke spikes and to improve empirical models of opacity or particulate matter used for engine calibration. It has been proposed by dimensional modeling that exhaust gas recirculation flow rate was significantly underestimated and volumetric efficiency was overestimated by the electronic control module during the turbocharger lag period of an electronically controlled heavy duty diesel engine. Factoring in cylinder-to-cylinder variation, it has been shown that the electronic control module estimated fuel-Oxygen ratio was lower than actual by up to 35% during the turbocharger lag period but within 2% of actual elsewhere, thus hindering fuel-Oxygen ratio limit-based smoke control. The dimensional modeling of transient flow was enabled with a new method of simulating transient data in which the manifold pressures and exhaust gas recirculation system flow resistance, characterized as a function of exhaust gas recirculation valve position at each measured transient data point, were replicated by quasi-static or transient simulation to predict engine flows. Dimensional modeling was also used to transform the engine operating parameter model input space to a more fundamental lower dimensional space so that a nearest neighbor approach could be used to predict smoke emissions. This new approach, intended for engine calibration and control modeling, was termed the "nonparametric reduced dimensionality" approach. It was used to predict federal test procedure cumulative particulate matter within 7% of measured value, based solely on steady-state training data. Very little correlation between the model inputs in the transformed space was observed as compared to the engine operating parameter space. This more uniform, smaller, shrunken model input space might explain how the nonparametric reduced dimensionality approach model could successfully predict federal test procedure emissions when roughly 40% of all transient points were classified as outliers as per the steady-state training data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Icy debris fans have are newly-described landforms (Kochel and Trop, 2008 and 2012) as landforms developed immediately after deglaciation on Earth and similar features have been observed on Mars. Subsurface characteristics of Icy debris fans have not been previously investigated. Ground penetrating radar (GPR) was used to non-invasively investigate the subsurface characteristics of icy debris fans near McCarthy, Alaska, USA. The three fans investigated in Alaska are the East, West, and Middle fans (Kochel and Trop, 2008 and 2012) which below the Nabesna ice cap and on top of the McCarthy Creek Glacier. Icy debris fans in general are a largely unexplored suite of paraglacial landforms and processes in alpine regions. Recent field studies focused on direct observations and depositional processes. Their results showed that the fan's composition is primarily influenced by the type and frequency of depositional processes that supply the fan. Photographic studies show that the East Fan receives far more ice and snow avalanches whereas the Middle and West Fans receive fewer mass wasting events but more clastic debris is deposited on the Middle and West fan from rock falls and icy debris flows. GPR profiles and Wide-angle reflection and refraction (WARR) surveys consisting of both, common mid-point (CMP), and common shot-point (CSP) surveys investigated the subsurface geometry of the fans and the McCarthy Creek Glacier. All GPR surveys were collected in July of 2013 with 100MHz bi-static antennas. Four axial profiles and three cross-fan profiles were done on the West and Middle fans as well as the McCarthy Creek Glacier in order to investigate the relationship between the three features. GPR profiles yielded reflectors that were continuous for 10+ m and hyperbolic reflections in the subsurface. The depth to these reflections in the subsurface requires knowledge of the velocity of the subsurface. To find the velocity of the subsurface eight WARR surveys collected on the fans and on the McCarthy Creek glacier to provide information on variability of subsurface velocities. The profiles of the Middle and West fan have more reflections in their profiles compared to profiles done on the McCarthy Creek Glacier. Based on the WARR surveys, we interpret the lower energy return in the glacier to be caused by two reasons. 1) The increased attenuation due to wet ice versus drier ice and on the fan with GPR velocities >0.15m/ns. 2) Lack of interfaces in the glacier compared to those in the fans which are inferred to be produced by the alternating layers of stratified ice and lithic-rich layers. The GPR profiles on the West and Middle Fans show the shallow subsurface being dominated by lenticular reflections interpreted to be consistent with the shape of surficial deposits. The West Fan is distinguished from the Middle Fan by the nature of its reflections patterns and thicknesses of reflection packages that clearly shows the Middle fan with a greater thickness. The changes in subsurface reflections between the Middle and West Fans as well as the McCarthy Creek Glacier are thought to reflect the type and frequency of depositional processes and surrounding bedrock and talus slopes.