5 resultados para Three factor model
em Bucknell University Digital Commons - Pensilvania - USA
Resumo:
The Multiple Affect Adjective Check List (MAACL) has been found to have five first-order factors representing Anxiety, Depression, Hostility, Positive Affect, and Sensation Seeking and two second-order factors representing Positive Affect and Sensation Seeking (PASS) and Dysphoria. The present study examines whether these first- and second-order conceptions of affect (based on R-technique factor analysis) can also account for patterns of intraindividual variability in affect (based on P-technique factor analysis) in eight elderly women. Although the hypothesized five-factor model of affect was not testable in all of the present P-technique datasets, the results were consistent with this interindividual model of affect. Moreover, evidence of second-order (PASS and Dysphoria) and third-order (generalized distress) factors was found in one data set. Sufficient convergence in findings between the present P-technique research and prior R-technique research suggests that the MAACL is robust in describing both inter- and intraindividual components of affect in elderly women.
Resumo:
This study presents a new inventory to assess thought-action fusion (TAF). 160 college students ages 18 to 22 (M = 19.17, SD = 1.11) completed the new Modified Thought Action Scale (MTAFS). Results indicated high internal consistency in the MTAFS (Cronbach’s α = .95). A principal component analysis suggested a three factor solution of TAF-Moral (TAFM), TAFLikelihood (TAFL), and TAF-Harm avoidance-Positive (TAFHP) all with eigenvalues above 1, and factor loadings above .4. A second study examined the association between TAF, obsessivecompulsive and anxiety tendencies after the activation of TAF-like thought processes in a nonclinical sample (n=76). Subjects were randomly assigned to one of three treatment groups intended to provoke TAFL-self, TAFL-other, and TAF moral thought processes. Stepwise regression analyses revealed: 1) the Obsessive-Compulsive Inventory subscales Neutralizing and Ordering significantly predicted instructed neutralization behavior (INB) in non-clinical participants; 2) TAF-Likelihood contributed significant unique variance in INB. These findings suggest that the provocation of neutralization behavior may be mediated by specific subsets of TAF and obsessive-compulsive tendencies.
Resumo:
The short, portable mental status questionnaire (SPMSQ) developed by Pfeiffer has several advantages over previous short instruments designed to assess the intellectual functioning of older adults. It is based upon data from both institutionalized and community-dwelling elderly. Although Pfeiffer a four-group classification, he used to groups in his initial validation study: (a) intact/mildly impaired, and (b) moderately/severely impaired. The present study compared clinicians' ratings with those based upon the SPMSQ scores, and examined the validity of the four-group classification. The sample included 181 subjects from seven intermediate care facilities and nine home-care agencies. All were assessed by the OARS questionnaire, which includes the SPMSQ Three discriminant analyses were performed with three different criteria, for two-group, three-group, and four-group models. Results indicated that the two-group model (intact/mildly impaired and moderately/severely impaired) permitted significant discrimination. The four-group model, however, gave less distinct results. In particular, patients who were mildly intellectually impaired could not be clearly distinguished from those who were intact and from those who were moderately impaired. The three-group model (minimally, moderately, severely impaired) seemed to offer the best compromise between the gross dichotomy of the original two-model system and the less accurate four category system.
Measurement Properties of the Short Multi-Dimensional Observation Scale for Elderly Subjects (MOSES)
Resumo:
This study evaluated the five-factor measurement model of the abbreviated Multidimensional Observation Scale for Elderly Subjects (MOSES), originally proposed by Pruchno, Kleban, and Resch in 1988. Modifications of the five-factor model were examined and evaluated with regard to their practical significance. A confirmatory second-order factor analysis was performed to examine whether the correlations among the first-order factors were adequately accounted for by a global dysfunction factor. Findings indicated that the proposed measurement model was replicated adequately. Although post hoc modifications resulted in significant improvements in overall model fit, the minor parameters had only a trivial influence on the major parameters of the baseline model. Results from the second-order factor analysis showed that a global dysfunc tion factor accounted adequately for the intercorrelations among the first-order factors.
Resumo:
Solid oxide fuel cell (SOFC) technology has the potential to be a significant player in our future energy technology repertoire based on its ability to convert chemical energy into electrical energy. Infiltrated SOFCs, in particular, have demonstrated improved performance and at lower cost than traditional SOFCs. An infiltrated electrode comprises porous ceramic scaffolding (typically constructed from the oxygen ion conducting material) that is infiltrated with electron conducting and catalytic particles. Two important SOFC electrode properties are effective conductivity and three phase boundary density (TPB). Researchers study these electrode properties separately, and fail to recognize them as competing properties. This thesis aims to (1) develop a method to model the TPB density and use it to determine the effect of porosity, scaffolding particle size, and pore former size on TPB density as well as to (2) compare the effect of porosity, scaffolding particle size, and pore former size on TPB density and effective conductivity to determine a desired set of parameters for infiltrated SOFC electrode performance. A computational model was used to study the effect of microstructure parameters on the effective conductivity and TPB density of the infiltrated SOFC electrode. From this study, effective conductivity and TPB density are determined to be competing properties of SOFC electrodes. Increased porosity, scaffolding particle size, and pore former particle size increase the effective conductivity for a given infiltrate loading above percolation threshold. Increased scaffolding particle size and pore former size ratio, however, decreases the TPB density. The maximum TPB density is achievable between porosities of 45% and 60%. The effect of microstructure parameters are more prominent at low loading with scaffolding particle size being the most significant factor and pore former size ratio being the least significant factor.