2 resultados para Sinter-HIP

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Placing portal incisions during arthroscopic hip surgery presents challenges for surgeons in terms of anatomic accessibility and patient safety. Based on key anatomic landmarks and portal placement information from recent literature, suggested portal incisions were determined. Guidance in the placement of the three most common portal incision locations (anterior, anterolateral, and posterolateral) for arthroscopic surgery; in addition to visual feedback on tool trajectory to the hip joint is provided in real time by a computer aided system for hip arthroscopy. By simplifying the portal placement process, one of the most challenging aspects of arthroscopic hip surgery, an increased use of this minimally invasive technique could be possible. In addition to portal information, improvements to an existing computer aided system for arthroscopic hip surgery, including a new hip model and redesigned mechanical tracking linkage, were completed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While beneficially decreasing the necessary incision size, arthroscopic hip surgery increases the surgical complexity due to loss of joint visibility. To ease such difficulty, a computer-aided mechanical navigation system was developed to present the location of the surgical tool relative to the patient¿s hip joint. A preliminary study reduced the position error of the tracking linkage with limited static testing trials. In this study, a correction method, including a rotational correction factor and a length correction function, was developed through more in-depth static testing. The developed correction method was then applied to additional static and dynamic testing trials to evaluate its effectiveness. For static testing, the position error decreased from an average of 0.384 inches to 0.153 inches, with an error reduction of 60.5%. Three parameters utilized to quantify error reduction of dynamic testing did not show consistent results. The vertex coordinates achieved 29.4% of error reduction, yet with large variation in the upper vertex. The triangular area error was reduced by 5.37%, however inconsistent among all five dynamic trials. Error of vertex angles increased, indicating a shape torsion using the developed correction method. While the established correction method effectively and consistently reduced position error in static testing, it did not present consistent results in dynamic trials. More dynamic paramters should be explored to quantify error reduction of dynamic testing, and more in-depth dynamic testing methodology should be conducted to further improve the accuracy of the computer-aided nagivation system.