2 resultados para Non-magnetic Nanosized Spinel Oxides
em Bucknell University Digital Commons - Pensilvania - USA
Resumo:
The radiation environment of space presents a significant threat to the reliability of nonvolatile memory technologies. Ionizing radiation disturbs the charge stored on floating gates, and cosmic rays can permanently damage thin oxides. A new memory technology based on the magnetic tunneling junction (MTJ) appears to offer superior resistance to radiation effects and virtually unlimited write endurance. A magnetic flip flop has a number of potential applications, such as the configuration memory in field-programmable logic devices. However, using MTJs in a flip flop requires radically different circuitry for storing and retrieving data. New techniques are needed to insure that magnetic flip flops are reliable in the radiation environment of space. We propose a new radiation-tolerant magnetic flip flop that uses the inherent resistance of the MTJ to increase its immunity to single event upset and employs a robust “Pac-man” magnetic element.
Resumo:
Recent optimizations of NMR spectroscopy have focused their attention on innovations in new hardware, such as novel probes and higher field strengths. Only recently has the potential to enhance the sensitivity of NMR through data acquisition strategies been investigated. This thesis has focused on the practice of enhancing the signal-to-noise ratio (SNR) of NMR using non-uniform sampling (NUS). After first establishing the concept and exact theory of compounding sensitivity enhancements in multiple non-uniformly sampled indirect dimensions, a new result was derived that NUS enhances both SNR and resolution at any given signal evolution time. In contrast, uniform sampling alternately optimizes SNR (t < 1.26T2) or resolution (t~3T2), each at the expense of the other. Experiments were designed and conducted on a plant natural product to explore this behavior of NUS in which the SNR and resolution continue to improve as acquisition time increases. Possible absolute sensitivity improvements of 1.5 and 1.9 are possible in each indirect dimension for matched and 2x biased exponentially decaying sampling densities, respectively, at an acquisition time of ¿T2. Recommendations for breaking into the linear regime of maximum entropy (MaxEnt) are proposed. Furthermore, examination into a novel sinusoidal sampling density resulted in improved line shapes in MaxEnt reconstructions of NUS data and comparable enhancement to a matched exponential sampling density. The Absolute Sample Sensitivity derived and demonstrated here for NUS holds great promise in expanding the adoption of non-uniform sampling.