3 resultados para Hip height

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

More than 250,000 hip fractures occur annually in the United States and the most common fracture location is the femoral neck, the weakest region of the femur. Hip fixation surgery is conducted to repair hip fractures by using a Kirschner (K-) wire as a temporary guide for permanent bone screws. Variation has been observed in the force required to extract the K-wire from the femoral head during surgery. It is hypothesized that a relationship exists between the K-wire pullout force and the bone quality at the site of extraction. Currently, bone mineral density (BMD) is used as a predictor for bone quality and strength. However, BMD characterizes the entire skeletal system and does not account for localized bone quality and factors such as lifestyle, nutrition, and drug use. A patient’s BMD may not accurately describe the quality of bone at the site of fracture. This study aims to investigate a correlation between the force required to extract a K-wire from femoral head specimens and the quality of bone. A procedure to measure K-wire pullout force was developed and tested with pig femoral head specimens. The procedure was implemented on 8 human osteoarthritic femoral head specimens and the average pullout force for each ranged from 563.32 ± 240.38 N to 1041.01 ± 346.84 N. The data exhibited significant variation within and between each specimen and no statistically significant relationships were determined between pullout force and patient age, weight, height, BMI, inorganic to organic matter ratio, and BMD. A new testing fixture was designed and manufactured to merge the clinical and research environments by enabling the physician to extract the K-wire from each bone specimen himself. The new device allows the physician to gather tactile feedback on the relative ease of extraction while load history is recorded similar to the previous procedure for data acquisition. Future work will include testing human bones with the new device to further investigate correlations for predicting bone quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Placing portal incisions during arthroscopic hip surgery presents challenges for surgeons in terms of anatomic accessibility and patient safety. Based on key anatomic landmarks and portal placement information from recent literature, suggested portal incisions were determined. Guidance in the placement of the three most common portal incision locations (anterior, anterolateral, and posterolateral) for arthroscopic surgery; in addition to visual feedback on tool trajectory to the hip joint is provided in real time by a computer aided system for hip arthroscopy. By simplifying the portal placement process, one of the most challenging aspects of arthroscopic hip surgery, an increased use of this minimally invasive technique could be possible. In addition to portal information, improvements to an existing computer aided system for arthroscopic hip surgery, including a new hip model and redesigned mechanical tracking linkage, were completed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While beneficially decreasing the necessary incision size, arthroscopic hip surgery increases the surgical complexity due to loss of joint visibility. To ease such difficulty, a computer-aided mechanical navigation system was developed to present the location of the surgical tool relative to the patient¿s hip joint. A preliminary study reduced the position error of the tracking linkage with limited static testing trials. In this study, a correction method, including a rotational correction factor and a length correction function, was developed through more in-depth static testing. The developed correction method was then applied to additional static and dynamic testing trials to evaluate its effectiveness. For static testing, the position error decreased from an average of 0.384 inches to 0.153 inches, with an error reduction of 60.5%. Three parameters utilized to quantify error reduction of dynamic testing did not show consistent results. The vertex coordinates achieved 29.4% of error reduction, yet with large variation in the upper vertex. The triangular area error was reduced by 5.37%, however inconsistent among all five dynamic trials. Error of vertex angles increased, indicating a shape torsion using the developed correction method. While the established correction method effectively and consistently reduced position error in static testing, it did not present consistent results in dynamic trials. More dynamic paramters should be explored to quantify error reduction of dynamic testing, and more in-depth dynamic testing methodology should be conducted to further improve the accuracy of the computer-aided nagivation system.