3 resultados para Force balance system

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and purpose: Numerous interventions have been proposed to improve balance in older adults with varying degrees of success. A novel approach may be to use an off-the-shelf video game system utilizing real-time force feedback to train older adults. The purpose of this study is to investigate the feasibility of using Nintendo's Wii Fit for training to improve clinical measures of balance in older adults and to retain the improvements after a period of time. Methods: Twelve healthy older adults (aged >70 years) were randomly divided into two groups. The experimental group completed training using Nintendo's Wii Fit game three times a week for 3 weeks while the control group continued with normal activities. Four clinical measures of balance were assessed before training, 1 week after training, and 1 month after training: Berg Balance Scale (BBS), Fullerton Advanced Balance (FAB) scale, Functional Reach (FR), and Timed Up and Go (TUG). Friedman two-way analysis of variance by ranks was conducted on the control and experimental group to determine if training using the Wii Balance Board with Wii Fit had an influence on clinical measures of balance. Results: Nine older adults completed the study (experimental group n = 4, control group n = 5). The experimental group significantly increased their BBS after training while the control group did not. There was no significant change for either group with FAB, FR, and TUG. Conclusion: Balance training with Nintendo's Wii Fit may be a novel way for older adults to improve balance as measured by the BBS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

More than 250,000 hip fractures occur annually in the United States and the most common fracture location is the femoral neck, the weakest region of the femur. Hip fixation surgery is conducted to repair hip fractures by using a Kirschner (K-) wire as a temporary guide for permanent bone screws. Variation has been observed in the force required to extract the K-wire from the femoral head during surgery. It is hypothesized that a relationship exists between the K-wire pullout force and the bone quality at the site of extraction. Currently, bone mineral density (BMD) is used as a predictor for bone quality and strength. However, BMD characterizes the entire skeletal system and does not account for localized bone quality and factors such as lifestyle, nutrition, and drug use. A patient’s BMD may not accurately describe the quality of bone at the site of fracture. This study aims to investigate a correlation between the force required to extract a K-wire from femoral head specimens and the quality of bone. A procedure to measure K-wire pullout force was developed and tested with pig femoral head specimens. The procedure was implemented on 8 human osteoarthritic femoral head specimens and the average pullout force for each ranged from 563.32 ± 240.38 N to 1041.01 ± 346.84 N. The data exhibited significant variation within and between each specimen and no statistically significant relationships were determined between pullout force and patient age, weight, height, BMI, inorganic to organic matter ratio, and BMD. A new testing fixture was designed and manufactured to merge the clinical and research environments by enabling the physician to extract the K-wire from each bone specimen himself. The new device allows the physician to gather tactile feedback on the relative ease of extraction while load history is recorded similar to the previous procedure for data acquisition. Future work will include testing human bones with the new device to further investigate correlations for predicting bone quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atmospheric aerosols affect both global and regional climate by altering the radiative balance of the atmosphere and acting as cloud condensation nuclei. Despite an increased focus on the research of atmospheric aerosols due to concerns about global climate change, current methods to observe the morphology of aerosols and to measure their hygroscopic properties are limited in various ways by experimental procedure. The primary objectives of this thesis were to use atomic force microscopy to determine the morphology of atmospherically relevant aerosols and to investigate theutility of environmental atomic force microscopy for imaging aerosols as they respond to changes in relative humidity. Traditional aerosol generation and collection techniques were used in conjunction with atomic force microscopy to image commonorganic and inorganic aerosols. In addition, environmental AFM was used to image aerosols at a variety of relative humidity values. The results of this research demonstrated the utility of atomic force microscopy for measuring the morphology of aerosols. In addition, the utility of environmental AFM for measuring the hygroscopic properties of aerosols was demonstrated. Further research in this area will lead to an increased understanding of the role oforganic and inorganic aerosols in the atmosphere, allowing for the effects of anthropogenic aerosol emissions to be quantified and for more accurate climate models to be developed.