3 resultados para Entanglement measure

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum channel identification, a standard problem in quantum metrology, is the task of estimating parameter(s) of a quantum channel. We investigate dissonance (quantum discord in the absence of entanglement) as an aid to quantum channel identification and find evidence for dissonance as a resource for quantum information processing. We consider the specific case of dissonant Bell-diagonal probes of the qubit depolarizing channel, using quantum Fisher information as a measure of statistical information extracted by the probe. In this setting dissonant quantum probes yield more statistical information about the depolarizing probability than do corresponding probes without dissonance and greater dissonance yields greater information. This effect only operates consistently when we control for classical correlation between the probe and its ancilla and the joint and marginal purities of the ancilla and probe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel microfluidic method is proposed for studying diffusion of small molecules in a hydrogel. Microfluidic devices were prepared with semi-permeable microchannels defined by crosslinked poly(ethylene glycol) (PEG). Uptake of dye molecules from aqueous solutions flowing through the microchannels was observedoptically and diffusion of the dye into the hydrogel was quantified. To complement the diffusion measurements from the microfluidic studies, nuclear magnetic resonance(NMR) characterization of the diffusion of dye in the PEG hydrogels was performed. The diffusion of small molecules in a hydrogel is relevant to applications such asdrug delivery and modeling transport for tissue-engineering applications. The diffusion of small molecules in a hydrogel is dependent on the extent of crosslinking within the gel, gel structure, and interactions between the diffusive species and the hydrogel network. These effects were studied in a model environment (semi-infinite slab) at the hydrogelfluid boundary in a microfluidic device. The microfluidic devices containing PEG microchannels were fabricated using photolithography. The unsteady diffusion of small molecules (dyes) within the microfluidic device was monitored and recorded using a digital microscope. The information was analyzed with techniques drawn from digital microscopy and image analysis to obtain concentration profiles with time. Using a diffusion model to fit this concentration vs. position data, a diffusion coefficient was obtained. This diffusion coefficient was compared to those from complementary NMR analysis. A pulsed field gradient (PFG) method was used to investigate and quantify small molecule diffusion in gradient (PFG) method was used to investigate and quantify small molecule diffusion in hydrogels. There is good agreement between the diffusion coefficients obtained from the microfluidic methods and those found from the NMR studies. The microfluidic approachused in this research enables the study of diffusion at length scales that approach those of vasculature, facilitating models for studying drug elution from hydrogels in blood-contacting applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug release from a fluid-contacting biomaterial is simulated using a microfluidic device with a channel defined by solute-loaded hydrogel; as water is pumped through the channel, solute transfers from the hydrogel into the water. Optical analysis of in-situ hydrogels, characterization of the microfluidic device effluent, and NMR methods were used to find diffusion coefficients of several dyes (model drugs) in poly( ethylene glycol) diacrylate (PEG-DA) hydrogels. Diffusion coefficients for methylene blue and sulforhodamine 101 in PEG-DA calculated using the three methods are in good agreement; both dyes are mobile in the hydrogel and elute from the hydrogel at the aqueous channel interface. However, the dye acid blue 22 deviates from typical diffusion behavior and does not release as expected from the hydrogel. Importantly, only the microfluidic method is capable of detecting this behavior. Characterizing solute diffusion with a combination of NMR, optical and effluent methods offer greater insight into molecular diffusion in hydrogels than employing each technique individually. The NMR method made precise measurements for solute diffusion in all cases. The microfluidic optical method was effective for visualizing diffusion of the optically active solutes. The optical and effluent methods show potential to be used to screen solutes to determine if they elute from a hydrogel in contact with flowing fluid. Our data suggest that when designing a drug delivery device, analyzing the diffusion from the molecular level to the device level is important to establish a complete picture of drug elution, and microfluidic methods to study such diffusion can play a key role. (C) 2013 Elsevier B.V. All rights reserved.