6 resultados para Diffusion of innovations

em Bucknell University Digital Commons - Pensilvania - USA


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many research-based instruction strategies (RBISs) have been developed; their superior efficacy with respect to student learning has been demonstrated in many studies. Collecting and interpreting evidence about: 1) the extent to which electrical and computer engineering (ECE) faculty members are using RBISs in core, required engineering science courses, and 2) concerns that they express about using them, are important aspects of understanding how engineering education is evolving. The authors surveyed ECE faculty members, asking about their awareness and use of selected RBISs. The survey also asked what concerns ECE faculty members had about using RBISs. Respondent data showed that awareness of RBISs was very high, but estimates of use of RBISs, based on survey data, varied from 10% to 70%, depending on characteristics of the strategy. The most significant concern was the amount of class time that using an RBIS might take; efforts to increase use of RBISs must address this.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrogels are composed of cross-linked networks of hydrophilic polymers that are biocompatible due to their high water content. Mass transfer through hydrogels has been suggested as an effective method of drug delivery, specifically in degradable polymers to minimize lasting effects within the body. Diffusion of small molecules in poly (ethylene glycol) diacrylate (PEG-DA) and dextran methacrylate (dex-MA) hydrogels was characterized in a microfluidic device and by complementary techniques. Microfluidic devices were prepared by crosslinking a formulation of hydrogel and photo-initiator, with and without visible dye, using photolithography to define a central microchannel. Channel sizes within the devices were approximately 600 ¿m to simulate vessels within the body. The microfluidic technique allows for both image and effluent analyses. To visualize the diffusive behavior within the dextran hydrogel, methylene blue and sulforhodamine 101 dyes were used in both elution and uptake experiments. Three analysis techniques for measuring diffusion coefficients were used to quantify the diffusion of solute in the hydrogel, including optical microscopy, characterization of device effluent, and NMR analyses. The optical microscopy technique analyzes images of the dye diffusion captured by a stereomicroscope to generate dye concentration v. position profiles. The data was fit to a diffusion model to determine diffusion coefficients and the dye release profile. In a typical elution experiment, aqueous solution is pumped through the microchannel and dye diffuses out of the hydrogel and into the aqueous phase. During elution, images are taken at regular time intervals and the effluent was collected. Analysis of the device effluent was performed using ultraviolet-visible (UV/Vis) spectroscopy to determine the effluent dye concentration and thus a short-time diffusion coefficient. Nuclear magnetic resonance (NMR) was used to determine a free diffusion coefficient of molecules in hydrogel without the effect of a concentration gradient. Diffusion coefficients for methylene blue and sulforhodamine 101 dyes in dex-MA hydrogel calculated using the three analysis methods all agree well. It was determined that utilizing a combination of the three techniques offers greater insight into molecular diffusion in hydrogels than employing each technique individually. The use of the same microfluidic devices used to measure diffusion is explored in the use of studying the degradation of dex-MA hydrogels. By combining what is known about the degradation rate in regards to the effect of pH and crosslinking and the ability to use a dye solution in contrast to establish the hydrogel boundaries could be a novel approach to studying hydrogel degradation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study investigates the effect of cell phones on economic development and growth by performing an econometric analysis using data from the International Telecommunications Union and the Penn World Table. It discusses the various ways cell phones can make markets more efficient and how the diffusion of information andknowledge plays into development. Several approaches (OLS, Fixed Effects, 2SLS) were used to test over 20 econometric models. Overall, the mobile cellular subscriptions rate was found to have a positive and significant impact on countries’ level of real per capitaGDP and GDP growth rate. Furthermore, the study provides policy implications for the use of technology to promote global growth.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Microfluidic devices can be used for many applications, including the formation of well-controlled emulsions. In this study, the capability to continuously create monodisperse droplets in a microfluidic device was used to form calcium-alginate capsules.Calcium-alginate capsules have many potential uses, such as immunoisolation of cells and microencapsulation of active drug ingredients or bitter agents in food or beverage products. The gelation of calcium-alginate capsules is achieved by crosslinking sodiumalginate with calcium ions. Calcium ions dissociated from calcium carbonate due to diffusion of acetic acid from a sunflower oil phase into an aqueous droplet containing sodium-alginate and calcium carbonate. After gelation, the capsules were separated from the continuous oil phase into an aqueous solution for use in biological applications. Typically, capsules are separated bycentrifugation, which can damage both the capsules and the encapsulated material. A passive method achieves separation without exposing the encapsulated material or the capsules to large mechanical forces, thereby preventing damage. To achieve passiveseparation, the use of a microfluidic device with opposing channel wa hydrophobicity was used to stabilize co-laminar flow of im of hydrophobicity is accomplished by defining one length of the channel with a hydrogel. The chosen hydrogel was poly (ethylene glycol) diacrylate, which adheres to the glass surface through the use of self-assembled monolayer of 3-(trichlorosilyl)-propyl methacrylate. Due to the difference in surface energy within the channel, the aqueous stream is stabilized near a hydrogel and the oil stream is stabilized near the thiolene based optical adhesive defining the opposing length of the channel. Passive separation with co-laminar flow has shown success in continuously separating calcium-alginatecapsules from an oil phase into an aqueous phase. In addition to successful formation and separation of calcium alginate capsules,encapsulation of Latex micro-beads and viable mammalian cells has been achieved. The viability of encapsulated mammalian cells was determined using a live/dead stain. The co-laminar flow device has also been demonstrated as a means of separating liquid-liquidemulsions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel microfluidic method is proposed for studying diffusion of small molecules in a hydrogel. Microfluidic devices were prepared with semi-permeable microchannels defined by crosslinked poly(ethylene glycol) (PEG). Uptake of dye molecules from aqueous solutions flowing through the microchannels was observedoptically and diffusion of the dye into the hydrogel was quantified. To complement the diffusion measurements from the microfluidic studies, nuclear magnetic resonance(NMR) characterization of the diffusion of dye in the PEG hydrogels was performed. The diffusion of small molecules in a hydrogel is relevant to applications such asdrug delivery and modeling transport for tissue-engineering applications. The diffusion of small molecules in a hydrogel is dependent on the extent of crosslinking within the gel, gel structure, and interactions between the diffusive species and the hydrogel network. These effects were studied in a model environment (semi-infinite slab) at the hydrogelfluid boundary in a microfluidic device. The microfluidic devices containing PEG microchannels were fabricated using photolithography. The unsteady diffusion of small molecules (dyes) within the microfluidic device was monitored and recorded using a digital microscope. The information was analyzed with techniques drawn from digital microscopy and image analysis to obtain concentration profiles with time. Using a diffusion model to fit this concentration vs. position data, a diffusion coefficient was obtained. This diffusion coefficient was compared to those from complementary NMR analysis. A pulsed field gradient (PFG) method was used to investigate and quantify small molecule diffusion in gradient (PFG) method was used to investigate and quantify small molecule diffusion in hydrogels. There is good agreement between the diffusion coefficients obtained from the microfluidic methods and those found from the NMR studies. The microfluidic approachused in this research enables the study of diffusion at length scales that approach those of vasculature, facilitating models for studying drug elution from hydrogels in blood-contacting applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Drug release from a fluid-contacting biomaterial is simulated using a microfluidic device with a channel defined by solute-loaded hydrogel; as water is pumped through the channel, solute transfers from the hydrogel into the water. Optical analysis of in-situ hydrogels, characterization of the microfluidic device effluent, and NMR methods were used to find diffusion coefficients of several dyes (model drugs) in poly( ethylene glycol) diacrylate (PEG-DA) hydrogels. Diffusion coefficients for methylene blue and sulforhodamine 101 in PEG-DA calculated using the three methods are in good agreement; both dyes are mobile in the hydrogel and elute from the hydrogel at the aqueous channel interface. However, the dye acid blue 22 deviates from typical diffusion behavior and does not release as expected from the hydrogel. Importantly, only the microfluidic method is capable of detecting this behavior. Characterizing solute diffusion with a combination of NMR, optical and effluent methods offer greater insight into molecular diffusion in hydrogels than employing each technique individually. The NMR method made precise measurements for solute diffusion in all cases. The microfluidic optical method was effective for visualizing diffusion of the optically active solutes. The optical and effluent methods show potential to be used to screen solutes to determine if they elute from a hydrogel in contact with flowing fluid. Our data suggest that when designing a drug delivery device, analyzing the diffusion from the molecular level to the device level is important to establish a complete picture of drug elution, and microfluidic methods to study such diffusion can play a key role. (C) 2013 Elsevier B.V. All rights reserved.