97 resultados para thorax vibrations
em BORIS: Bern Open Repository and Information System - Berna - Sui
Resumo:
A planar-spiral antenna to be used in an ultrawideband (UWB) radar system for heart activity monitoring is presented. The antenna, named “twin,” is constituted by two spiral dipoles in a compact structure. The reflection coefficient at the feed point of the dipoles is lower than −8 dB over the 3–12 GHz band, while the two-dipoles coupling is about −20 dB. The radiated beam is perpendicular to the plane of the spiral, so the antenna is wearable and it may be an optimal radiator for a medical UWB radar for heart rate detection. The designed antenna has been also used to check some hypotheses about the UWB radar heart activity detection mechanism. The radiation impedance variation, caused by the thorax vibrations associated with heart activity, seems to be the most likely explanation of the UWB radar operation.
Resumo:
In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process.
Resumo:
The N-H center dot center dot center dot pi hydrogen bond is an important intermolecular interaction in many biological systems. We have investigated the infrared (IR) and ultraviolet (UV) spectra of the supersonic-jet cooled complex of pyrrole with benzene and benzene-d(6) (Pyr center dot Bz, Pyr center dot Bz-d(6)). DFT-D density functional, SCS-MP2 and SCS-CC2 calculations predict a T-shaped and (almost) C(s) symmetric structure with an N-H center dot center dot center dot pi hydrogen bond to the benzene ring. The pyrrole is tipped by omega(S(0)) = +/- 13 degrees relative to the surface normal of Bz. The N center dot center dot center dot ring distance is 3.13 angstrom. In the S(1) excited state, SCS-CC2 calculations predict an increased tipping angle omega(S(1)) = +/- 21 degrees. The IR depletion spectra support the T-shaped geometry: The NH stretch is redshifted by -59 cm(-1), relative to the "free" NH stretch of pyrrole at 3531 cm(-1), indicating a moderately strong N-H center dot center dot center dot pi interaction. The interaction is weaker than in the (Pyr)(2) dimer, where the NH donor shift is -87 cm(-1) [Dauster et al., Phys. Chem. Chem. Phys., 2008, 10, 2827]. The IR C-H stretch frequencies and intensities of the Bz subunit are very similar to those of the acceptor in the (Bz)(2) dimer, confirming that Bz acts as the acceptor. While the S(1) <- S(0) electronic origin of Bz is forbidden and is not observable in the gas-phase, the UV spectrum of Pyr center dot Bz in the same region exhibits a weak 0(0)(0) band that is red-shifted by 58 cm(-1) relative to that of Bz (38 086 cm(-1)). The origin appears due to symmetry-breaking of the p-electron system of Bz by the asymmetric pyrrole NH center dot center dot center dot pi hydrogen bond. This contrasts with (Bz)(2), which does not exhibit a 0(0)(0) band. The Bz moiety in Pyr center dot Bz exhibits a 6a(0)(1) band at 0(0)(0) + 518 cm(-1) that is about 20x more intense than the origin band. The symmetry breaking by the NH center dot center dot center dot pi hydrogen bond splits the degeneracy of the v(6)(e(2g)) vibration, giving rise to 6a' and 6b' sub-bands that are spaced by similar to 6 cm(-1). Both the 0(0)(0) and 6(0)(1) bands of Pyr center dot Bz carry a progression in the low-frequency (10 cm(-1)) excited-state tipping vibration omega', in agreement with the change of the omega tipping angle predicted by SCS-MP2 and SCS-CC2 calculations.
Resumo:
PURPOSE: Computer-based feedback systems for assessing the quality of cardiopulmonary resuscitation (CPR) are widely used these days. Recordings usually involve compression and ventilation dependent variables. Thorax compression depth, sufficient decompression and correct hand position are displayed but interpreted independently of one another. We aimed to generate a parameter, which represents all the combined relevant parameters of compression to provide a rapid assessment of the quality of chest compression-the effective compression ratio (ECR). METHODS: The following parameters were used to determine the ECR: compression depth, correct hand position, correct decompression and the proportion of time used for chest compressions compared to the total time spent on CPR. Based on the ERC guidelines, we calculated that guideline compliant CPR (30:2) has a minimum ECR of 0.79. To calculate the ECR, we expanded the previously described software solution. In order to demonstrate the usefulness of the new ECR-parameter, we first performed a PubMed search for studies that included correct compression and no-flow time, after which we calculated the new parameter, the ECR. RESULTS: The PubMed search revealed 9 trials. Calculated ECR values ranged between 0.03 (for basic life support [BLS] study, two helpers, no feedback) and 0.67 (BLS with feedback from the 6th minute). CONCLUSION: ECR enables rapid, meaningful assessment of CPR and simplifies the comparability of studies as well as the individual performance of trainees. The structure of the software solution allows it to be easily adapted to any manikin, CPR feedback devices and different resuscitation guidelines (e.g. ILCOR, ERC).
Resumo:
OBJECTIVE: The aim of this study was to determine if two different whole body vibration, sinusoidal vibration (SV) and stochastic resonance vibration (SRV), using various intensities lead to a reactive activation of pelvic floor muscles. STUDY DESIGN: We compared the pelvic floor muscle response of a healthy control group with that of a post partum group with weakened pelvic floor contraction. Activation effects of stochastic resonance vibration and sinusoidal vibration with six increasing vibration intensities were investigated using pelvic floor EMG and compared to activity during rest and maximum voluntary contraction. RESULTS: Both whole body vibration systems were able to activate pelvic floor muscles significantly depending on vibration intensity. Generally, the SRV achieved a significantly higher activation than maximum voluntary contraction, especially in women post partum and using a frequency of 6-12 Hz. CONCLUSION: SRV, compared to SV, leads to higher pelvic floor muscle activation in subjects with weakened pelvic floor muscles and achieves higher pelvic floor activation than maximum voluntary contraction alone. Neurourol. Urodynam. 28:405-410, 2009. (c) 2009 Wiley-Liss, Inc.
Resumo:
Background: Obesity is a growing problem in industrial nations. The aim of this study was to determine the relationship between the body mass index (BMI) and the pattern of injury after polytrauma. Methods: This retrospective study included 651 patients with an injury severity score (ISS) ≥16 and aged ≥16 years who were subdivided into three groups: BMI < 25 kg/m2, BMI 25–30 kg/m2, and BMI > 30 kg/m2. The Abbreviated Injury Scale (AIS) was used to quantify the injuries in the different anatomical regions. The Murray score was assessed at admission and at its maximum during hospitalization to evaluate pulmonary problems. Data are presented as means ± standard errors of the means. One way analysis of variance, χ2 test and Kruskal-Wallis test were used for the analyses and the significance level was set at p < 0.05. Results: The AIS of the thorax was 3.2 ± 0.1 in the BMI < 25 kg/m2 group, 3.3 ± 0.1 in the BMI 25–30 kg/m2 group, and 2.8 ± 0.2 in the BMI > 30 kg/m2 group; p < 0.05. The Murray score at admission increased significantly with increasing BMI (0.8 ± 0.8 for BMI < 25 kg/m2, 0.9 ± 0.9 for BMI 25–30 kg/m2, and 1.0 ± 0.8 for BMI > 30 kg/m2; p < 0.05) as was the maximum Murray score during hospitalization (1.2 ± 0.9 for BMI < 25 kg/m2, 1.6 ± 1.0 for BMI 25–30 kg/m2, and 1.5 ± 0.9 for BMI > 30 kg/m2; p < 0.001). The number of ventilator days was also elevated significantly with increasing BMI (5.9 ± 0.4 for BMI < 25 kg/m2, 7.7 ± 0.8 for BMI 25–30 kg/m2, and 7.9 ± 1.6 for BMI > 30 kg/m2; p < 0.05). Conclusion: Overweight and obesity lead to a higher incidence of thoracic trauma in a polytrauma situation and may additionally handicap ventilation in an obstructive manner.
Resumo:
Vibrations, Posture, and the Stabilization of Gaze: An Experimental Study on Impedance Control R. KREDEL, A. GRIMM & E.-J. HOSSNER University of Bern, Switzerland Introduction Franklin and Wolpert (2011) identify impedance control, i.e., the competence to resist changes in position, velocity or acceleration caused by environmental disturbances, as one of five computational mechanisms which allow for skilled and fluent sen-sorimotor behavior. Accordingly, impedance control is of particular interest in situa-tions in which the motor task exhibits unpredictable components as it is the case in downhill biking or downhill skiing. In an experimental study, the question is asked whether impedance control, beyond its benefits for motor control, also helps to stabi-lize gaze what, in turn, may be essential for maintaining other control mechanisms (e.g., the internal modeling of future states) in an optimal range. Method In a 3x2x4 within-subject ANOVA design, 72 participants conducted three tests on visual acuity and contrast (Landolt / Grating and Vernier) in two different postures (standing vs. squat) on a platform vibrating at four different frequencies (ZEPTOR; 0 Hz, 4 Hz, 8 Hz, 12 Hz; no random noise; constant amplitude) in a counterbalanced or-der with 1-minute breaks in-between. In addition, perceived exertion (Borg) was rated by participants after each condition. Results For Landolt and Grating, significant main effects for posture and frequency are re-vealed, representing lower acuity/contrast thresholds for standing and for higher fre-quencies in general, as well as a significant interaction (p < .05), standing for in-creasing posture differences with increasing frequencies. Overall, performance could be maintained at the 0 Hz/standing level up to a frequency of 8 Hz, if bending of the knees was allowed. The fact that this result is not only due to exertion is proved by the Borg ratings showing significant main effects only, i.e., higher exertion scores for standing and for higher frequencies, but no significant interaction (p > .40). The same pattern, although not significant, is revealed for the Vernier test. Discussion Apparently, postures improving impedance control not only turn out to help to resist disturbances but also assist in stabilizing gaze in spite of these perturbations. Con-sequently, studying the interaction of these control mechanisms in complex unpre-dictable environments seems to be a fruitful field of research for the future. References Franklin, D. W., & Wolpert, D. M. (2011). Computational mechanisms of sensorimotor control. Neuron, 72, 425-442.