12 resultados para Product-Service System

em BORIS: Bern Open Repository and Information System - Berna - Sui


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: In general cantons regulate and control the Swiss health service system; patient flows within and between cantons are thereby partially disregarded. This paper develops an alternative spatial model, based upon the construction of orthopedic hospital service areas (HSAOs), and introduces indices for the analysis of patient streams in order to identify areas, irrespective of canton, with diverse characteristics, importance, needs, or demands. METHODS: HSAOs were constructed using orthopedic discharge data. Patient streams between the HSAOs were analysed by calculating three indices: the localization index (% local residents discharged locally), the netindex (the ratio of discharges of nonlocal incoming residents to outgoing local residents), and the market share index (% of local resident discharges of all discharges in local hospitals). RESULTS: The 85 orthopedic HSAOs show a median localization index of 60.8%, a market share index of 75.1%, and 30% of HSAOs have a positive netindex. Insurance class of bed, admission type, and patient age are partially but significantly associated with those indicators. A trend to more centrally provided health services can be observed not only in large urban HSAOs such as Geneva, Bern, Basel, and Zurich, but also in HSAOs in mountain sport areas such as Sion, Davos, or St.Moritz. Furthermore, elderly and emergency patients are more frequently treated locally than younger people or those having elective procedures. CONCLUSION: The division of Switzerland into HSAOs provides an alternative spatial model for analysing and describing patient streams for health service utilization. Because this small area model allows more in-depth analysis of patient streams both within and between cantons, it may improve support and planning of resource allocation of in-patient care in the Swiss healthcare system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present manuscript is to present the advances performed in medicine using a Personalized Decision Support System (PDSS). The models used in Decision Support Systems (DSS) are examined in combination with Genome Information and Biomarkers to produce personalized result for each individual. The concept of personalize medicine is described in depth and application of PDSS for Cardiovascular Diseases (CVD) and Type-1 Diabetes Mellitus (T1DM) are analyzed. Parameters extracted from genes, biomarkers, nutrition habits, lifestyle and biological measurements feed DSSs, incorporating Artificial Intelligence Modules (AIM), to provide personalized advice, medication and treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Numerous bacterial pathogens subvert cellular functions of eukaryotic host cells by the injection of effector proteins via dedicated secretion systems. The type IV secretion system (T4SS) effector protein BepA from Bartonella henselae is composed of an N-terminal Fic domain and a C-terminal Bartonella intracellular delivery domain, the latter being responsible for T4SS-mediated translocation into host cells. A proteolysis resistant fragment (residues 10-302) that includes the Fic domain shows autoadenylylation activity and adenylyl transfer onto Hela cell extract proteins as demonstrated by autoradiography on incubation with α-[(32)P]-ATP. Its crystal structure, determined to 2.9-Å resolution by the SeMet-SAD method, exhibits the canonical Fic fold including the HPFxxGNGRxxR signature motif with several elaborations in loop regions and an additional β-rich domain at the C-terminus. On crystal soaking with ATP/Mg(2+), additional electron density indicated the presence of a PP(i) /Mg(2+) moiety, the side product of the adenylylation reaction, in the anion binding nest of the signature motif. On the basis of this information and that of the recent structure of IbpA(Fic2) in complex with the eukaryotic target protein Cdc42, we present a detailed model for the ternary complex of Fic with the two substrates, ATP/Mg(2+) and target tyrosine. The model is consistent with an in-line nucleophilic attack of the deprotonated side-chain hydroxyl group onto the α-phosphorus of the nucleotide to accomplish AMP transfer. Furthermore, a general, sequence-independent mechanism of target positioning through antiparallel β-strand interactions between enzyme and target is suggested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new Swiss implant system SPI became available three years ago and is used in combination with fixed and removable prosthetic reconstructions. In a pilot study the clinical procedures were evaluated and data of prosthetic complications of maintenance service were collected. 25 patients participated in the study with a total of 79 SPI implants during the time period from 2003-2004. 37 implants were located in the maxilla and 42 implants in the mandible. Two implants failed during the healing period, but no loaded implant was lost. Thus, the survival rate was 97.5% (77/79). 44 implants supported a fixed prosthesis, including nine single crowns and 33 implants were used in combination with removable partial denture. Four implants were used with ball anchor retention, 29 with bar support. The ELEMENT implant with the low implant shoulder allows very good esthetics. Prosthetic complications and maintenance service during the first year of function was comparable with other implant systems. Since the design of the abutment screws, healing caps and screwdriver was changed, the system has become easier in its application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Data from 59 farms with complaints of udder health problems and insufficient quality of delivered milk that had been assessed by the Swiss Bovine Health Service (BHS) between 1999 and 2004 were retrospectively analysed. Data evaluated included farm characteristics such as farm size, herd size, average milk yield, milking system and housing system, deficits of the milking equipment and the milking practices, and bacteriological results of milk samples from all cows in lactation. The average size of the farms assessed by the BHS was larger than the size of the were evaluated, 42 showed obvious failures which the farm managers could have noticed. Only 5 of the 57 milkers carried out their work according to the generally valid guidelines of the National Mastitis Council. More than 2 basic mistakes were observed in the milking practices of 36 milkers. In 51 farms, mixed infections with several problem bacteria (those present in at least 20 % of the tested cows on a farm) were found. Staphylococcus aureus proved to be the most common problem germ. As the bacteria responsible for the herd problem (the sole problem bacteria detectable on a particular farm) Staphylococcus aureus was detected in 4 farms. The current study revealed that education in the area of milking techniques and milking practices of farmers should be improved in order to reduce the incidence of udder health problems on herd level. Staphylococcus aureus is the most important problem bacteria involved in herds with udder health problems in Switzerland. Staphylococcus aureus might be used in practice as the indicator germ for early recognition of management problems in dairy farms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. Supporting algorithms, which allow the adjustment of the opening angle and the maximum noise suppression, are proposed and evaluated. A portable real-time device for test in real acoustic environments is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, an Insulin Infusion Advisory System (IIAS) for Type 1 diabetes patients, which use insulin pumps for the Continuous Subcutaneous Insulin Infusion (CSII) is presented. The purpose of the system is to estimate the appropriate insulin infusion rates. The system is based on a Non-Linear Model Predictive Controller (NMPC) which uses a hybrid model. The model comprises a Compartmental Model (CM), which simulates the absorption of the glucose to the blood due to meal intakes, and a Neural Network (NN), which simulates the glucose-insulin kinetics. The NN is a Recurrent NN (RNN) trained with the Real Time Recurrent Learning (RTRL) algorithm. The output of the model consists of short term glucose predictions and provides input to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. For the development and the evaluation of the IIAS, data generated from a Mathematical Model (MM) of a Type 1 diabetes patient have been used. The proposed control strategy is evaluated at multiple meal disturbances, various noise levels and additional time delays. The results indicate that the implemented IIAS is capable of handling multiple meals, which correspond to realistic meal profiles, large noise levels and time delays.