Over the last decade, translational science has come into the focus of academic medicine, and significant intellectual and financial efforts have been made to initiate a multitude of bench-to-bedside projects. The quest for suitable biomarkers that will significantly change clinical practice has become one of the biggest challenges in translational medicine. Quantitative measurement of proteins is a critical step in biomarker discovery. Assessing a large number of potential protein biomarkers in a statistically significant number of samples and controls still constitutes a major technical hurdle. Multiplexed analysis offers significant advantages regarding time, reagent cost, sample requirements and the amount of data that can be generated. The two contemporary approaches in multiplexed and quantitative biomarker validation, antibody-based immunoassays and MS-based multiple (or selected) reaction monitoring, are based on different assay principles and instrument requirements. Both approaches have their own advantages and disadvantages and therefore have complementary roles in the multi-staged biomarker verification and validation process. In this review, we discuss quantitative immunoassay and multiple reaction monitoring/selected reaction monitoring assay principles and development. We also discuss choosing an appropriate platform, judging the performance of assays, obtaining reliable, quantitative results for translational research and clinical applications in the biomarker field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to refine a multi-dimensional scale based on physiological and behavioural parameters, known as the post abdominal surgery pain assessment scale (PASPAS), to quantify pain after laparotomy in horses. After a short introduction, eight observers used the scale to assess eight horses at multiple time points after laparotomy. In addition, a single observer was used to test the correlation of each parameter with the total pain index in 34 patients, and the effect of general anaesthesia on PASPAS was investigated in a control group of eight horses. Inter-observer variability was low (coefficient of variation 0.3), which indicated good reliability of PASPAS. The correlation of individual parameters with the total pain index differed between parameters. PASPAS, which was not influenced by general anaesthesia, was a useful tool to evaluate pain in horses after abdominal surgery and may also be useful to investigate analgesic protocols or for teaching purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The anteromedial thigh (AMT) flap is reviewed in terms of its vascular anatomy and previous clinical reports in the literature. Our own series of 5 patients treated with this flap for defects in the head and neck region and lower extremity is presented. Although several authors controversially discussed vasculature, we constantly found the pedicle as an emerging septocutaneous perforator at a point where the medial border of the rectus femoris muscle is crossed by the sartorius muscle. In all 5 patients, the AMT flap provided stable coverage with no flap loss. Based on our findings, we conclude that the anteromedial thigh flap offers all the advantages of fasciocutaneous flaps. Therefore, we recommend this flap as an alternative for defects requiring coverages of thin to moderate skin thickness. However, it should be remembered that variations in vascular anatomy are possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although rarely used, the abductor hallucis muscle has its indications in coverage of small defects at the medial aspect of the hindfoot as a proximally based muscle flap. The authors describe a 69-year-old female patient in whom the abductor hallucis muscle was used as a distally based flap to reconstruct a defect in the forefoot. An anatomic study was undertaken on two cadaveric feet to explore the practicality of the distally based abductor hallucis muscle flap before it was applied clinically. The distally based abductor muscle flap receives its blood supply from minor and major pedicles in a retrograde fashion from both the dorsal arterial network and the deep plantar system, through communicating branches with the medial plantar artery distally. Transposition of the distally based hallucis flap is only advisable in individuals who have no vascular compromise in the lower leg and foot. To the authors' knowledge, this modification has not yet been described in the available literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gastrin releasing peptide (GRP) is a regulatory peptide that acts through its receptor (GRPR) to regulate physiological functions in various organs. GRPR is overexpressed in neoplastic cells of most prostate cancers and some renal cell cancers and in the tumoral vessels of urinary tract cancers. Thus, targeting these tumours with specifically designed GRP analogues has potential clinical application. Potent and specific radioactive, cytotoxic or nonradioactive GRP analogues have been designed and tested in various animal tumour models with the aim of receptor targeting for tumour diagnosis or therapy. All three categories of compound were found suitable for tumour targeting in animal models. The cytotoxic and nonradioactive GRP analogues have not yet shown convincing tumour-reducing effects in human trials; however, the first clinical studies of radioactive GRP analogues--both agonists and antagonists--suggest promising opportunities for both diagnostic tumour imaging and radiotherapy of prostate and other GRPR-expressing cancers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This abstract presents the biomechanical model that is used in the European ContraCancrum project, aiming at simulating tumor evolution in the brain and lung. The construction of the finite element model as well as a simulation of tumor growth are shown. The construction of the mesh is fully automatic and is therefore compatible with a clinical application. This biomechanical model will be later combined to a cellular level simulator also developed in the project.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The in vitro production of recombinant protein molecules has fostered a tremendous interest in their clinical application for treatment and support of cancer patients. Therapeutic proteins include monoclonal antibodies, interferons, and haematopoietic growth factors. Clinically established monoclonal antibodies include rituximab (targeting CD20-positive B-cell lymphomas), trastuzumab (active in HER-2 breast and gastric cancer), and bevacizumab (blocking tumor-induced angiogenesis through blockade of vascular-endothelial growth factor and its receptor). Interferons have lost much of their initial appeal, since equally or more effective treatments with more pleasant side effects have become available, for example in chronic myelogenous leukaemia or hairy cell leukaemia. The value of recombinant growth factors, notably granulocyte colony stimulating factor (G-CSF) and erythropoietin is rather in the field of supportive care than in targeted anti-cancer therapy. Adequately powered clinical phase III trials are essential to estimate the true therapeutic impact of these expensive compounds, with appropriate selection of clinically relevant endpoints and sufficient follow-up. Monoclonal antibodies, interferons, and growth factors must also, and increasingly so, be subjected to close scrutiny by appropriate cost-effectiveness analyses to ensure that their use results in good value for money. With these caveats and under the condition of their judicious clinical use, recombinant proteins have greatly enriched the therapeutic armamentarium in clinical oncology, and their importance is likely to grow even further.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Multiparameter cerebral monitoring has been widely applied in traumatic brain injury to study posttraumatic pathophysiology and to manage head-injured patients (e.g., combining O(2) and pH sensors with cerebral microdialysis). Because a comprehensive approach towards understanding injury processes will also require functional measures, we have added electrophysiology to these monitoring modalities by attaching a recording electrode to the microdialysis probe. These dual-function (microdialysis/electrophysiology) probes were placed in rats following experimental fluid percussion brain injuries, and in a series of severely head-injured human patients. Electrical activity (cell firing, EEG) was monitored concurrently with microdialysis sampling of extracellular glutamate, glucose and lactate. Electrophysiological parameters (firing rate, serial correlation, field potential occurrences) were analyzed offline and compared to dialysate concentrations. In rats, these probes demonstrated an injury-induced suppression of neuronal firing (from a control level of 2.87 to 0.41 spikes/sec postinjury), which was associated with increases in extracellular glutamate and lactate, and decreases in glucose levels. When placed in human patients, the probes detected sparse and slowly firing cells (mean = 0.21 spike/sec), with most units (70%) exhibiting a lack of serial correlation in the spike train. In some patients, spontaneous field potentials were observed, suggesting synchronously firing neuronal populations. In both the experimental and clinical application, the addition of the recording electrode did not appreciably affect the performance of the microdialysis probe. The results suggest that this technique provides a functional monitoring capability which cannot be obtained when electrophysiology is measured with surface or epidural EEG alone.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES This study sought to validate the Logistic Clinical SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score in patients with non-ST-segment elevation acute coronary syndromes (ACS), in order to further legitimize its clinical application. BACKGROUND The Logistic Clinical SYNTAX score allows for an individualized prediction of 1-year mortality in patients undergoing contemporary percutaneous coronary intervention. It is composed of a "Core" Model (anatomical SYNTAX score, age, creatinine clearance, and left ventricular ejection fraction), and "Extended" Model (composed of an additional 6 clinical variables), and has previously been cross validated in 7 contemporary stent trials (>6,000 patients). METHODS One-year all-cause death was analyzed in 2,627 patients undergoing percutaneous coronary intervention from the ACUITY (Acute Catheterization and Urgent Intervention Triage Strategy) trial. Mortality predictions from the Core and Extended Models were studied with respect to discrimination, that is, separation of those with and without 1-year all-cause death (assessed by the concordance [C] statistic), and calibration, that is, agreement between observed and predicted outcomes (assessed with validation plots). Decision curve analyses, which weight the harms (false positives) against benefits (true positives) of using a risk score to make mortality predictions, were undertaken to assess clinical usefulness. RESULTS In the ACUITY trial, the median SYNTAX score was 9.0 (interquartile range 5.0 to 16.0); approximately 40% of patients had 3-vessel disease, 29% diabetes, and 85% underwent drug-eluting stent implantation. Validation plots confirmed agreement between observed and predicted mortality. The Core and Extended Models demonstrated substantial improvements in the discriminative ability for 1-year all-cause death compared with the anatomical SYNTAX score in isolation (C-statistics: SYNTAX score: 0.64, 95% confidence interval [CI]: 0.56 to 0.71; Core Model: 0.74, 95% CI: 0.66 to 0.79; Extended Model: 0.77, 95% CI: 0.70 to 0.83). Decision curve analyses confirmed the increasing ability to correctly identify patients who would die at 1 year with the Extended Model versus the Core Model versus the anatomical SYNTAX score, over a wide range of thresholds for mortality risk predictions. CONCLUSIONS Compared to the anatomical SYNTAX score alone, the Core and Extended Models of the Logistic Clinical SYNTAX score more accurately predicted individual 1-year mortality in patients presenting with non-ST-segment elevation acute coronary syndromes undergoing percutaneous coronary intervention. These findings support the clinical application of the Logistic Clinical SYNTAX score.