19 resultados para wide area measurement system (WAMS)
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7mmHgand-0.9+/- 0.5mmHg, respectively), withameanpulsepressureof3.4mmHg.ThedifferencebetweenthemeanCVPandCVPatend-diastoleduringexpirationwas0.58+/- 0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.
Resumo:
SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.
Resumo:
A new physics-based technique for correcting inhomogeneities present in sub-daily temperature records is proposed. The approach accounts for changes in the sensor-shield characteristics that affect the energy balance dependent on ambient weather conditions (radiation, wind). An empirical model is formulated that reflects the main atmospheric processes and can be used in the correction step of a homogenization procedure. The model accounts for short- and long-wave radiation fluxes (including a snow cover component for albedo calculation) of a measurement system, such as a radiation shield. One part of the flux is further modulated by ventilation. The model requires only cloud cover and wind speed for each day, but detailed site-specific information is necessary. The final model has three free parameters, one of which is a constant offset. The three parameters can be determined, e.g., using the mean offsets for three observation times. The model is developed using the example of the change from the Wild screen to the Stevenson screen in the temperature record of Basel, Switzerland, in 1966. It is evaluated based on parallel measurements of both systems during a sub-period at this location, which were discovered during the writing of this paper. The model can be used in the correction step of homogenization to distribute a known mean step-size to every single measurement, thus providing a reasonable alternative correction procedure for high-resolution historical climate series. It also constitutes an error model, which may be applied, e.g., in data assimilation approaches.
Resumo:
BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.
Resumo:
OBJECTIVE: A previous study of radiofrequency neurotomy of the articular branches of the obturator nerve for hip joint pain produced modest results. Based on an anatomical and radiological study, we sought to define a potentially more effective radiofrequency method. DESIGN: Ten cadavers were studied, four of them bilaterally. The obturator nerve and its articular branches were marked by wires. Their radiological relationship to the bone structures on fluoroscopy was imaged and analyzed. A magnetic resonance imaging (MRI) study was undertaken on 20 patients to determine the structures that would be encountered by the radiofrequency electrode during different possible percutaneous approaches. RESULTS: The articular branches of the obturator nerve vary in location over a wide area. The previously described method of denervating the hip joint did not take this variation into account. Moreover, it approached the nerves perpendicularly. Because optimal coagulation requires electrodes to lie parallel to the nerves, a perpendicular approach probably produced only a minimal lesion. In addition, MRI demonstrated that a perpendicular approach is likely to puncture femoral vessels. Vessel puncture can be avoided if an oblique pass is used. Such an approach minimizes the angle between the target nerves and the electrode, and increases the likelihood of the nerve being captured by the lesion made. Multiple lesions need to be made in order to accommodate the variability in location of the articular nerves. CONCLUSIONS: The method that we described has the potential to produce complete and reliable nerve coagulation. Moreover, it minimizes the risk of penetrating the great vessels. The efficacy of this approach should be tested in clinical trials.
Resumo:
The "International Federation of Clinical Chemistry" (IFCC) has developed a new international reference measurement system as anchor for worldwide standardization of HbA1c determinations. The use of IFCC-referenced methods results in "true" HbA1c-values that are 1 - 2% lower compared to traditional methods. This leads to potential risks of clinical misjudgement. For the evaluation of glycaemic control it is, therefore, important to know the method used, its normal range as well as possibilities of mathematical conversion of results. To reduce the risk of wrong interpretation of results the Swiss Society of Endocrinology and Diabetes recommends that reports of HbA1c clearly indicate whether the values are "IFCC-" or "DCCT-traceable". "IFCC"-results should best be reported in mmol/mol. In addition, the normal range has to be indicated properly.
Resumo:
Ex vivo porcine retina laser lesions applied with varying laser power (20 mW–2 W, 10 ms pulse, 196 lesions) are manually evaluated by microscopic and optical coherence tomography (OCT) visibility, as well as in histological sections immediately after the deposition of the laser energy. An optical coherence tomography system with 1.78 um axial resolution specifically developed to image thin retinal layers simultaneously to laser therapy is presented, and visibility thresholds of the laser lesions in OCT data and fundus imaging are compared. Optical coherence tomography scans are compared with histological sections to estimate the resolving power for small optical changes in the retinal layers, and real-time time-lapse scans during laser application are shown and analyzed quantitatively. Ultrahigh-resolution OCT inspection features a lesion visibility threshold 40–50 mW (17 reduction) lower than for visual inspection. With the new measurement system, 42 of the lesions that were invisible using state-of-the-art ophthalmoscopic methods could be detected.
Resumo:
In order to determine the extent and timing of dyke formation in the Ladakh Batholith we examined about 30 mostly andesitic dykes intruding the Ladakh batholith in a ca. 50 km wide area to the west of Leh (NW India). The dykes in the east of the area trend E-NE and those in the west trend N-NW. The difference in orientation is also evident in the petrography and isotopic signatures. The eastern dykes contain corroded quartz xenocrysts and show negative ε0(Nd) and positive ε0(Sr) values, where as the western dykes do not contain quartz xenocrysts and exhibit positive ε0(Nd) and near-zero ε0(Sr) values. The variability in Sr-Nd isotopes (ε0(Nd) = 3.6 to −9.6, ε0(Sr) = 0.4 to 143) and the quartz xenocrysts can best be explained by (differing degrees of) crustal assimilation of the parent magma of the dykes. Separated minerals from five dykes were dated by 40Ar-39Ar incremental heating: amphibole ages range between 50 and 54 Ma, and one biotite dated both by Rb-Sr and by 40Ar-39Ar gave an age of 45 Ma. One dated pseudotachylyte sample attests to brittle faulting at ca. 54 Ma. The combination of structural field evidence with petrographic, isotopic and geochronological analyses demonstrates that the dykes did not form from a single, progressively differentiating magma chamber, despite having formed in the same tectonic setting around the same time, and that processes such as crustal assimilation and magma mixing/mingling also played a significant role in magma petrogenesis.
Resumo:
Charcoal in unlaminated sediments dated by 210Pb was analysed by the pollen-slide and thin-section methods. The results were compared with the number and area of forest fires on different spatial scales in the area around Lago di Origlio as listed in the wildfire database of southern Switzerland since AD 1920. The influx of the number of charcoal particles > 75 µm2 in pollen slides correlates well with the number of annual forest fires recorded within a distance of 20-50 km from the coring site. Hence a size-class distinction or an area measurement by image analysis may not be absolutely necessary for the reconstruction of regional fire history. A regression equation was computed and tested against an independent data set. Its use makes it possible to estimate the charcoal area influx (or concentration) from the particle number influx (or concentration). Local fires within a radius of 2 km around the coring site correlate well with the area influx of charcoal particles estimated by the thin-section method measuring the area of charcoal particles larger than 20 000 µm2 or longer than 50 µm. Pollen percentages and influx values suggest that intensive agriculture and Castanea sativa cultivation were reduced 30-40 years ago, followed by an increase of forest area and a development to more natural woodlands. The traditional Castanea sativa cultivation was characterized by a complete use of the biomass produced, so abandonment of chestnut led to an increasing accumulation of dead biomass, thereby raising the fire risk. On the other hand, the pollen record of the regional vegetation does not show any clear response to the increase of fire frequency during the last three decades in this area.
Resumo:
Systems for the identification and registration of cattle have gradually been receiving attention for use in syndromic surveillance, a relatively recent approach for the early detection of infectious disease outbreaks. Real or near real-time monitoring of deaths or stillbirths reported to these systems offer an opportunity to detect temporal or spatial clusters of increased mortality that could be caused by an infectious disease epidemic. In Switzerland, such data are recorded in the "Tierverkehrsdatenbank" (TVD). To investigate the potential of the Swiss TVD for syndromic surveillance, 3 years of data (2009-2011) were assessed in terms of data quality, including timeliness of reporting and completeness of geographic data. Two time-series consisting of reported on-farm deaths and stillbirths were retrospectively analysed to define and quantify the temporal patterns that result from non-health related factors. Geographic data were almost always present in the TVD data; often at different spatial scales. On-farm deaths were reported to the database by farmers in a timely fashion; stillbirths were less timely. Timeliness and geographic coverage are two important features of disease surveillance systems, highlighting the suitability of the TVD for use in a syndromic surveillance system. Both time series exhibited different temporal patterns that were associated with non-health related factors. To avoid false positive signals, these patterns need to be removed from the data or accounted for in some way before applying aberration detection algorithms in real-time. Evaluating mortality data reported to systems for the identification and registration of cattle is of value for comparing national data systems and as a first step towards a European-wide early detection system for emerging and re-emerging cattle diseases.
Resumo:
The understanding of the continental carbon budget is essential to predict future climate change. In order to quantify CO₂ and CH₄ fluxes at the regional scale, a measurement system was installed at the former radio tower in Beromünster as part of the Swiss greenhouse gas monitoring network (CarboCount CH). We have been measuring the mixing ratios of CO₂, CH₄ and CO on this tower with sample inlets at 12.5, 44.6, 71.5, 131.6 and 212.5 m above ground level using a cavity ring down spectroscopy (CRDS) analyzer. The first 2-year (December 2012–December 2014) continuous atmospheric record was analyzed for seasonal and diurnal variations and interspecies correlations. In addition, storage fluxes were calculated from the hourly profiles along the tower. The atmospheric growth rates from 2013 to 2014 determined from this 2-year data set were 1.78 ppm yr⁻¹, 9.66 ppb yr⁻¹ and and -1.27 ppb yr⁻¹ for CO₂, CH₄ and CO, respectively. After detrending, clear seasonal cycles were detected for CO₂ and CO, whereas CH₄ showed a stable baseline suggesting a net balance between sources and sinks over the course of the year. CO and CO₂ were strongly correlated (r² > 0.75) in winter (DJF), but almost uncorrelated in summer. In winter, anthropogenic emissions dominate the biospheric CO₂ fluxes and the variations in mixing ratios are large due to reduced vertical mixing. The diurnal variations of all species showed distinct cycles in spring and summer, with the lowest sampling level showing the most pronounced diurnal amplitudes. The storage flux estimates exhibited reasonable diurnal shapes for CO₂, but underestimated the strength of the surface sinks during daytime. This seems plausible, keeping in mind that we were only able to calculate the storage fluxes along the profile of the tower but not the flux into or out of this profile, since no Eddy covariance flux measurements were taken at the top of the tower.
Resumo:
The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of sqrt(s) = 7 TeV corresponding to an integrated luminosity of 38 inverse pb. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0.4 or R=0.6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pt > 20 GeV and pseudorapidities eta<4.5. The JES systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams. The JES uncertainty is less than 2.5% in the central calorimeter region (eta<0.8) for jets with 60 < pt < 800 GeV, and is maximally 14% for pt < 30 GeV in the most forward region 3.2