35 resultados para wear strengthening and toughening

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prosthetic and osteosynthetic implants from metal alloys will be indispensable in orthopedic surgery, as long as tissue engineering and biodegradable bone substitutes do not lead to products that will be applied in clinical routine for the repair of bone, cartilage, and joint defects. Therefore, the elucidation of the interactions between the periprosthetic tissues and the implant remains of clinical relevance and several factors are known to affect the longevity of implants. Within this study, the effects of metal particles and surface topography on the recruitment of osteoclasts was investigated in vitro in a coculture of osteoblasts and bone marrow cells. The cells were grown in the presence of particles of different sizes and chemical composition or on metal discs with polished or sandblasted surfaces, respectively. At the end of the culture, newly formed osteoclasts were counted. Osteoclastogenesis was reduced when particles were added directly to the coculture. The effect depended on the size of the particles, small particles exerting stronger effects than larger ones. The chemical composition of the particles, however, did not affect the development of osteoclasts. In cocultures grown on sandblasted surfaces, osteoclasts developed at higher rates than they did in cultures on polished surfaces. The data demonstrate that wear particles and implant surfaces affect osteoclastogenesis and thus may be involved in the induction of local bone resorption and the formation of osteolytic lesions, leading eventually to the loosening of orthopedic implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Due to an increased focus on erosive tooth wear (ETW), the European Federation of Conservative Dentistry (EFCD) considered ETW as a relevant topic for generating this consensus report. MATERIALS AND METHODS This report is based on a compilation of the scientific literature, an expert conference, and the approval by the General Assembly of EFCD. RESULTS ETW is a chemical-mechanical process resulting in a cumulative loss of hard dental tissue not caused by bacteria, and it is characterized by loss of the natural surface morphology and contour of the teeth. A suitable index for classification of ETW is the basic erosive wear examination (BEWE). Regarding the etiology, patient-related factors include the pre-disposition to erosion, reflux, vomiting, drinking and eating habits, as well as medications and dietary supplements. Nutritional factors relate to the composition of foods and beverages, e.g., with low pH and high buffer capacity (major risk factors), and calcium concentration (major protective factor). Occupational factors are exposition of workers to acidic liquids or vapors. Preventive management of ETW aims at reducing or stopping the progression of the lesions. Restorative management aims at reducing symptoms of pain and dentine hypersensitivity, or to restore esthetic and function, but it should only be used in conjunction with preventive strategies. CONCLUSIONS Effective management of ETW includes screening for early signs of ETW and evaluating all etiological factors. CLINICAL RELEVANCE ETW is a clinical condition, which calls for the increased attention of the dental community and is a challenge for the cooperation with other medical specialities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine if storage for up to 4 h in human saliva results in a decrease of erosive tooth wear (ETW) and in an increase of surface microhardness (SMH) of enamel samples after an erosive attack with subsequent abrasion. Furthermore, we determined the impact of individual salivary parameters on ETW and SMH. Enamel samples were distributed into five groups: group 1 had neither erosion nor saliva treatment; groups 2-5 were treated with erosion, then group 2 was placed in a humid chamber and groups 3-5 were incubated in saliva for 30 min, 2 h, and 4 h, respectively. After erosion and saliva treatments, all groups were treated with abrasion. Surface microhardness and ETW were measured before and after erosion, incubation in saliva, and abrasion. Surface microhardness and ETW showed significant changes throughout the experiment: SMH decreased and ETW increased in groups 2-5, regardless of the length of incubation in saliva. The results of groups 3-5 (exposed to saliva) were not significantly different from those of group 2 (not exposed to saliva). Exposure of eroded enamel to saliva for up to 4 h was not able to increase SMH or reduce ETW. However, additional experiments with artificial saliva without proteins showed protection from erosive tooth wear. The recommendation to postpone toothbrushing of enamel after an erosive attack should be reconsidered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To determine whether particulate debris is present in periprosthetic tissue from revised Dynesys(®) devices, and if present, elicits a biological tissue reaction. METHODS Five Dynesys(®) dynamic stabilization systems consisting of pedicle screws (Ti alloy), polycarbonate-urethane (PCU) spacers and a polyethylene-terephthalate (PET) cord were explanted for pain and screw loosening after a mean of 2.86 years (1.9-5.3 years). Optical microscopy and scanning electron microscopy were used to evaluate wear, deformation and surface damage, and attenuated total reflectance Fourier transform infrared spectroscopy to assess surface chemical composition of the spacers. Periprosthetic tissue morphology and wear debris were determined using light microscopy, and PCU and PET wear debris by polarized light microscopy. RESULTS All implants had surface damage on the PCU spacers consistent with scratches and plastic deformation; 3 of 5 exhibited abrasive wear zones. In addition to fraying of the outer fibers of the PET cords in five implants, one case also evidenced cord fracture. The pedicle screws were unremarkable. Patient periprosthetic tissues around the three implants with visible PCU damage contained wear debris and a corresponding macrophage infiltration. For the patient revised for cord fracture, the tissues also contained large wear particles (>10 μm) and giant cells. Tissues from the other two patients showed comparable morphologies consisting of dense fibrous tissue with no inflammation or wear debris. CONCLUSIONS This is the first study to evaluate wear accumulation and local tissue responses for explanted Dynesys(®) devices. Polymer wear debris and an associated foreign-body macrophage response were observed in three of five cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Recommendations for lower extremity osteoarthritis (OA) and exercise have been primarily based on knee studies. To provide more targeted recommendations for the hip, we gathered evidence for the efficacy of exercise for hip OA from randomized controlled trials. METHODS: A bibliographic search identified trials that were randomized, controlled, completed by >or=60% of subjects, and involved an exercise group (strengthening and/or aerobic) versus a non exercise control group for pain relief in hip OA. Two reviewers independently performed the data extraction and contacted the authors when necessary. Effect sizes (ES) of treatment versus control and the I(2) statistic to assess heterogeneity across trials were calculated. Trial data were combined using a random-effects meta-analysis. RESULTS: Nine trials met the inclusion criteria (1,234 subjects), 7 of which combined hip and knee OA; therefore, we contacted the authors who provided the data on hip OA patients. In comparing exercise treatment versus control, we found a beneficial effect of exercise with an ES of -0.38 (95% confidence interval [95% CI] -0.68, -0.08; P = 0.01), but with high heterogeneity (I(2) = 75%) among trials. Heterogeneity was caused by 1 trial consisting of an exercise intervention that was not administered in person. Removing this study left 8 trials (n = 493) with similar exercise strategy (specialized hands-on exercise training, all of which included at least some element of muscle strengthening), and demonstrated exercise benefit with an ES of -0.46 (95% CI -0.64, -0.28; P < 0.0001). CONCLUSION: Therapeutic exercise, especially with an element of strengthening, is an efficacious treatment for hip OA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Wear of attachments leads to a loss of retention and potentially reduces the function of complete dentures. This study evaluated the retention force changes of different prefabricated attachment systems for implant-supported overdentures to estimate the wear constancy and applicability in clinical practice. METHODS: Four prefabricated attachment systems were tested [Group SG: retentive ball attachment (Straumann, Switzerland) with gold matrix, Group ST: retentive ball attachment (Straumann, Switzerland) with titanium spring matrix, Group IB: UNOR i-Ball with Ecco matrix (UNOR, Switzerland) and Group IMZ: IMZ-TwinPlus ball attachment with gold matrix (DENTSPLY Friadent, Germany)]. Ten samples of each system were subjected to 10,000 insertion-separation cycles. RESULTS: Results showed that all types of attachments showed wear, which led to a loss of retention force after an initial increase at the beginning of the wear simulation. Attachments with a plastic retention insert or gold matrices underwent the smallest changes in retention force. The titanium spring system showed the largest changes in retention force and a greater variation between the different cycles and specimen. This behaviour is probably caused by a large fitting tolerance of the titanium spring. CONCLUSIONS: Attachment systems which possess a male and female component of different material composition are preferable. They show smaller changes in the retention force. For retention force increase and wear compensation, an attachment system should be adjustable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to examine the wear behavior of conical crowns of gold alloy and zirconium dioxide ceramics facing electroplated gold copings.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Wear of attachments leads to a loss of retention and reduces the function of overdentures. This study evaluated the retention force changes of an attachment system for overdentures. The influence of the lubricant and the alloy on wear constancy was examined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper addresses methodological issues in the field of tooth wear and erosion research including the epidemiological indices, and identifies future work that is needed to improve knowledge about tooth wear and erosion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to report on the management and treatment outcomes of partially edentulous elderly patients with severe tooth wear.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To investigate the effect of curing rate on softening in ethanol, degree of conversion, and wear of resin composites. METHOD: With a given energy density and for each of two different light-curing units (QTH or LED), the curing rate was reduced by modulating the curing mode. Thus, the irradiation of resin composite specimens (Filtek Z250, Tetric Ceram, Esthet-X) was performed in a continuous curing mode and in a pulse-delay curing mode. Wallace hardness was used to determine the softening of resin composite after storage in ethanol. Degree of conversion was determined by infrared spectroscopy (FTIR). Wear was assessed by a three-body test. Data were submitted to Levene's test, one and three-way ANOVA, and Tukey HSD test (alpha = 0.05). Results: Immersion in ethanol, curing mode, and material all had significant effects on Wallace hardness. After ethanol storage, resin composites exposed to the pulse-delay curing mode were softer than resin composites exposed to continuous cure (P< 0.0001). Tetric Ceram was the softest material followed by Esthet-X and Filtek Z250 (P< 0.001). Only the restorative material had a significant effect on degree of conversion (P< 0.001): Esthet-X had the lowest degree of conversion followed by Filtek Z250 and Tetric Ceram. Curing mode (P= 0.007) and material (P< 0.001) had significant effect on wear. Higher wear resulted from the pulse-delay curing mode when compared to continuous curing, and Filtek Z250 showed the lowest wear followed by Esthet-X and Tetric Ceram.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY/PRINCIPLES: Analysis of changes in the behaviour of wearing protective equipment by alpine skiers and snowboarders after injury, performed at a level I trauma centre in Switzerland.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To provide an overview on diagnosis, risk factors and prevention of erosive tooth wear, which is becoming an increasingly important factor when considering the long- term health of the dentition. RESULTS: Awareness of dental erosion by the public is still not widespread due to the cryptic nature of this slowly progressing condition. Smooth silky-glazed appearance with the absence of perikymata and intact enamel along the gingival margin, with cupping and grooving on occlusal surfaces are some typical signs of enamel erosion. In later stages, it is sometimes difficult to distinguish between the influences of erosion, attrition or abrasion during a clinical examination. Biological, behavioral and chemical factors all come into play, which over time, may either wear away the tooth surface, or potentially protect it. In order to assess the risk factors, patient should record their dietary intake for a distinct period of time. Based on these analyses, an individually tailored preventive program may be suggested to patients. It may comprise dietary advice, optimization of fluoride regimes, stimulation of salivary flow rate, use of buffering medicaments and particular motivation for non-destructive tooth brushing habits. The frequent use of fluoride gel and fluoride mouthrinse in addition to fluoride toothpaste offers the opportunity to minimize abrasion of tooth substance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dental erosion is often described solely as a surface phenomenon, unlike caries where it has been established that the destructive effects involve both the surface and the subsurface region. However, besides removal and softening of the surface, erosion may show dissolution of mineral underneath the surface. There is some evidence that the presence of this condition is growing steadily. Hence, erosive tooth wear is becoming increasingly significant in the management of the long-term health of the dentition. What is considered as an acceptable amount of wear is dependent on the anticipated lifespan of the dentition and, therefore, is different for deciduous compared to permanent teeth. However, erosive damage to the permanent teeth occurring in childhood may compromise the growing child's dentition for their entire lifetime and may require repeated and increasingly complex and expensive restoration. Therefore, it is important that diagnosis of the tooth wear process in children and adults is made early and adequate preventive measures are undertaken. These measures can only be initiated when the risk factors are known and interactions between them are present. A scheme is proposed which allows the possible risk factors and their relation to each other to be examined.