73 resultados para vertebra malformation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We evaluated the feasibility of a modified embolization technique of pulmonary arteriovenous malformations (PAVM) using venous sac embolization with detachable coils combined with the feeding artery embolization with the Amplatzer vascular plug (AVP).
Resumo:
Monostotic fibrous dysplasia of the spine is a rare entity. Only 26 cases, of which 11 were located in the cervical spine, are to be found in the literature. We report a 56-year-old male patient with cervicobrachialgia of half year's duration. Radiographs showed a diffuse destruction of the vertebral body and the spinous process of C4. A biopsy of the spinous process confirmed histopathologically a fibrous dysplasia. Due to minor symptoms, no surgical treatment was performed or is planned unless in case of increasing pain, an acute instability or neurological symptoms.
Resumo:
As holoprosencephaly and Chiari II malformation differ considerably, both in pathogenesis and in phenotypic localization, the coincidence of both entities is extremely rare. The case presented is, to our knowledge, the first published report comprising a combination of a semilobar holoprosencephaly associated with a Chiari II malformation and a myelomeningocele diagnosed prenatally and confirmed by postmortem neuropathologic evaluation. These findings indicate that in the case of pre- and postnatal detection of a myelomeningocele and/or Chiari II malformation, possible additional intracranial malformation, such as a semilobar holoprosencephaly, should also be taken into account and vice versa.
Orbital venous malformation: percutaneous treatment using an electrolytically detachable fibred coil
Resumo:
PURPOSE: To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. METHODS: We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. RESULTS: Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. CONCLUSIONS: Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.
Resumo:
Vertebral cement augmentation can restore the stiffness and strength of a fractured vertebra and relieve chronic pain. Previous finite element analysis, biomechanical tests and clinical studies have indirectly associated new adjacent vertebral fractures following augmentation to altered loading. The aim of this repeated measures in situ biomechanical study was to determine the changes in the adjacent and augmented endplate deformation following cement augmentation of human cadaveric functional spine units (FSU) using micro-computed tomography (micro-CT). The surrounding soft tissue and posterior elements of 22 cadaveric human FSU were removed. FSU were assigned to two groups, control (n = 8) (loaded on day 1 and day 2) and augmented (n = 14) (loaded on day 1, augmented 20% cement fill, and loaded on day 2). The augmented group was further subdivided into a prophylactic augmentation group (n = 9), and vertebrae which spontaneously fractured during loading on day 1 (n = 5). The FSU were axially loaded (200, 1,000, 1,500-2,000 N) within a custom made radiolucent, saline filled loading device. At each loading step, FSUs were scanned using the micro-CT. Endplate heights were determined using custom software. No significant increase in endplate deformation following cement augmentation was noted for the adjacent endplate (P > 0.05). The deformation of the augmented endplate was significantly reduced following cement augmentation for both the prophylactic and fracture group (P < 0.05, P < 0.01, respectively). Endplate deformation of the controls showed no statistically significant differences between loading on day 1 and day 2. A linear relationship was noted between the applied compressive load and endplate deflection (R (2) = 0.58). Evidence of significant endplate deformation differences between unaugmented and augmented FSU, while evident for the augmented endplate, was not present for the adjacent endplate. This non-invasive micro-CT method may also be useful to investigate endplate failure, and parameters that predict vertebral failure.
Resumo:
A case of bilateral compound odontomas in the region of the third molars in the maxilla is reported. The differential diagnosis for this case is discussed.
Resumo:
Dandy-Walker-like malformation (DWLM) is the result of aberrant brain development and mainly characterized by cerebellar hypoplasia. DWLM affected dogs display a non-progressive cerebellar ataxia. Several DWLM cases were recently observed in the Eurasier dog breed, which strongly suggested a monogenic autosomal recessive inheritance in this breed. We performed a genome-wide association study (GWAS) with 9 cases and 11 controls and found the best association of DWLM with markers on chromosome 1. Subsequent homozygosity mapping confirmed that all 9 cases were homozygous for a shared haplotype in this region, which delineated a critical interval of 3.35 Mb. We sequenced the genome of an affected Eurasier and compared it with the Boxer reference genome and 47 control genomes of dogs from other breeds. This analysis revealed 4 private non-synonymous variants in the critical interval of the affected Eurasier. We genotyped these variants in additional dogs and found perfect association for only one of these variants, a single base deletion in the VLDLR gene encoding the very low density lipoprotein receptor. This variant, VLDLR:c.1713delC is predicted to cause a frameshift and premature stop codon (p.W572Gfs*10). Variants in the VLDLR gene have been shown to cause congenital cerebellar ataxia and mental retardation in human patients and Vldlr knockout mice also display an ataxia phenotype. Our combined genetic data together with the functional knowledge on the VLDLR gene from other species thus strongly suggest that VLDLR:c.1713delC is indeed causing DWLM in Eurasier dogs.
Resumo:
Automated identification of vertebrae from X-ray image(s) is an important step for various medical image computing tasks such as 2D/3D rigid and non-rigid registration. In this chapter we present a graphical model-based solution for automated vertebra identification from X-ray image(s). Our solution does not ask for a training process using training data and has the capability to automatically determine the number of vertebrae visible in the image(s). This is achieved by combining a graphical model-based maximum a posterior probability (MAP) estimate with a mean-shift based clustering. Experiments conducted on simulated X-ray images as well as on a low-dose low quality X-ray spinal image of a scoliotic patient verified its performance.