46 resultados para unity gain buffer

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Small animal models are widely used in basic research. However, experimental systems requiring extracorporeal circuits are frequently confronted with limitations related to equipment size. This is particularly true for oxygenators in systems with limited volumes. Thus we aimed to develop and validate an ultra mini-oxygenator for low-volume, buffer-perfused systems. Methods: We have manufactured a series of ultra mini-oxygenators with approximately 175 aligned, microporous, polypropylene hollow fibers contained inside a shell, which is sealed at each of the two extremities to isolate perfusate and gas compartments. With this construction, gas passes through hollow fibers, while perfusate circulates around fibers. Performance of ultra mini-oxygenators (oxygen partial pressure (PO2 ), gas and perfusate flow, perfusate pressure and temperature drop) were assessed with modified Krebs-Henseleit buffer in an in vitro perfusion circuit and an ex vivo rat heart preparation. Results: Mean priming volume of ultra mini-oxygenators was 1.2±0.5 mL and, on average, 86±6% of fibers were open (n=17). In vitro, effective oxygenation (PO2=400-500 mmHg) was achieved for all flow rates up to 50 mL/min and remained stable for at least 2 hours (n=5). Oxygenation was also effective and stable (PO2=456±40 mmHg) in the isolated heart preparation for at least 60 minutes ("venous" PO2=151±11 mmHg; n=5). Conclusions: We have established a reproducible procedure for fabrication of ultra mini-oxygenators, which provide reliable and stable oxygenation for at least 60-120 min. These oxygenators are especially attractive for pre-clinical protocols using small, rather than large, animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the prevalence of chromosome 8q gain in clear cell renal cell carcinoma (CCRCC) and to correlate the findings with tumor phenotype and disease-specific survival (DSS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrated all-fiber amplification of 11 ps pulses from a gain-switched laser diode at 1064 nm. The diode was driven at a repetition rate of 40 MHz and delivered 13 µW of fiber-coupled average output power. For the low output pulse energy of 325 fJ we have designed a multi-stage core pumped pre-amplifier in order to keep the contribution of undesired amplified spontaneous emission as low as possible. By using a novel time-domain approach for determining the power spectral density ratio (PSD) of signal to noise, we identified the optimal working point for our pre-amplifier. After the pre-amplifier we reduced the 40 MHz repetition rate to 1 MHz using a fiber coupled pulse-picker. The final amplification was done with a cladding pumped Yb-doped large mode area fiber and a subsequent Yb-doped rod-type fiber. With our setup we reached a total gain of 73 dB, resulting in pulse energies of >5.6 µJ and peak powers of >0.5 MW. The average PSD-ratio of signal to noise we determined to be 18/1 at the output of the final amplification stage.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low cardiac output impairs the hepatic arterial buffer response (HABR). Whether this is due to low abdominal blood flow per se is not known. Dobutamine is commonly used to increase cardiac output, and it may further modify hepatosplanchnic and renal vasoregulation. We assessed the effects of isolated abdominal aortic blood flow changes and dobutamine on hepatosplanchnic and renal blood flow. Twenty-five anesthetized pigs with an abdominal aorto-aortic shunt were randomized to 2 control groups [zero (n = 6) and minimal (n = 6) shunt flow], and 2 groups with 50% reduction of abdominal blood flow and either subsequent increased abdominal blood flow by shunt reduction (n = 6) or dobutamine infusion at 5 and 10 microg kg(-1) min(-1) with constant shunt flow (n = 7). Regional (ultrasound) and local (laser Doppler) intra-abdominal blood flows were measured. The HABR was assessed during acute portal vein occlusion. Sustained low abdominal blood flow, by means of shunt activation, decreased liver, gut, and kidney blood flow similarly and reduced local microcirculatory blood flow in the jejunum. Shunt flow reduction partially restored regional blood flows but not jejunal microcirculatory blood flow. Low-but not high-dose dobutamine increased gut and celiac trunk flow whereas hepatic artery and renal blood flows remained unchanged. Neither intervention altered local blood flows. The HABR was not abolished during sustained low abdominal blood flow despite substantially reduced hepatic arterial blood flow and was not modified by dobutamine. Low-but not high-dose dobutamine redistributes blood flow toward the gut and celiac trunk. The jejunal microcirculatory flow, once impaired, is difficult to restore.