122 resultados para unilateral loading

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study the changes in blood volume and hormones controlling sodium and water homeostasis after infusions of 0.9% saline, Gelofusine (4% succinylated gelatin in 0.7% saline, weight-average molecular weight 30 kD), and Voluven (6% hydroxyethyl starch in 0.9% saline, weight-average molecular weight 130 kD) in healthy volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To retrospectively evaluate the craniofacial morphology of children with a complete unilateral cleft lip and palate treated with a 1-stage simultaneous cleft repair performed in the first year of life. METHODS: Cephalograms and extraoral profile photographs of 61 consecutively treated patients (42 boys, 19 girls) who had been operated on at 9.2 (SD, 2.0) months by a single experienced surgeon were analyzed at 11.4 (SD, 1.5) years. The noncleft control group comprised 81 children (43 boys and 38 girls) of the same ethnicity at the age of 10.4 (SD, 0.5) years. RESULTS: In children with cleft, the maxilla and mandible were retrusive; the palatal and mandibular planes were more open, and sagittal maxillomandibular relationship was less favorable in comparison to noncleft control subjects. Soft tissues in patients with cleft reflected retrusive morphology of hard tissues--subnasal and supramental regions were less convex, profile was flatter, and nasolabial angle was more acute relative to those of the control subjects. CONCLUSIONS: Craniofacial morphology after 1-stage repair was deviated in comparison with noncleft control subjects. However, the degree of deviation was comparable with that found after treatment with alternative surgical protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to compare dental arch relationship following one-stage and three-stage surgical protocols of unilateral cleft lip and palate. Dental casts of 61 children (mean age, 11.2 years; SD, 1.7), consecutively treated in one center with one-stage closure of the complete cleft at 9.2 months (SD, 2.0), were compared with a sample of 97 patients (mean age, 8.7 years; SD, 0.9), consecutively treated with a three-stage protocol including delayed hard palate closure in another center. The dental casts were assigned random numbers to blind their origin. Four raters graded dental arch relationship and palatal morphology using the EUROCRAN index. The strength of agreement of rating was assessed with kappa statistics. Independent t tests were run to compare the EUROCRAN scores between one-stage and three-stage samples, and Fisher's exact tests were performed to evaluate differences of distribution of the EUROCRAN grades. The intra- and inter-rater agreement was moderate to very good. Dental arch relationship in the one-stage sample was less favorable than in three-stage group (mean scores, 2.58 and 1.97 for one-stage and three-stage samples, respectively; p?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates 3-year success rates of titanium screw-type implants with a chemically modified sandblasted and acid-etched surface (mod SLA), which were functionally loaded after 3 weeks of healing. METHODS: A total of 56 implants, inserted in the posterior mandibles of 39 partially edentulous patients, underwent undisturbed healing for 3 weeks. At day 21, the implants were fully loaded with provisional crowns. Definitive metal ceramic restorations were fabricated after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 36 months after implant placement. The soft tissue and radiographic parameters for the mod SLA implants after 3 years in function were compared to a historic control group of implants with an SLA surface using an early loading protocol after 6 weeks. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and were left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants, including the "spinners," showed favorable clinical and radiographic findings at the 3-year follow-up examination. All 56 implants were considered successfully integrated, resulting in a 3-year survival and success rate of 100%. Dental implants with a mod SLA surface demonstrated statistically significant differences for probing depths and clinical attachment level values compared to the historic control group, with the mod SLA surface implants having overall lower probing depths and clinical attachment level scores. CONCLUSION: This prospective study using an early loading protocol demonstrates that titanium implants with the mod SLA surface can achieve and maintain successful tissue integration over a period of 3 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. MATERIAL AND METHODS: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations in full occlusion. Definitive metal ceramic restorations were fabricated and positioned on each implant after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 24 months after implant placement. RESULTS: Of the 89 inserted implants, two (2.2%) implants failed to integrate and were removed during healing, and two (2.2%) additional implants required a prolonged healing time. A total of 85 (95.6%) implants were therefore loaded without incident after 21 days of healing. No additional implant was lost throughout the study period, whereas one implant was lost to follow-up and therefore left unaccounted for further analysis. The remaining 86 implants all exhibited favorable radiographic and clinical findings. Based on strict success criteria, these implants were considered successfully integrated 2 years after insertion, resulting in a 2-year success rate of 97.7%. CONCLUSION: The results of this prospective two-center study demonstrate that titanium implants with a modified SLA surface can predictably achieve successful tissue integration when loaded in full occlusion 21 days after placement. Integration could be maintained without incident for at least 2 years of follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The data of 46 adults with single-sided sensorineural deafness who were candidates for bone-anchored hearing aids (Baha) CROS (contralateral routing of signals) were analyzed. All candidates tested a Baha with a headband in their normal environment. Subsequently, 29 of the candidates chose a permanent Baha CROS fitting, and 17 declined, thus forming the two study groups. No significant difference regarding age, sex or duration of deafness was found between the two groups. Similarly, the transcranial attenuation was not significantly different between those who accepted and declined a Baha. Subjects with some residual hearing in their poorer ear tended to decline a Baha, but the effect was not statistically significant. For a subset of 28 subjects, the Bern Benefit in Single-Sided Deafness questionnaire was administered. The questionnaire consists of 10 visual analogue scales rating the subjectively perceived benefit of the Baha or any other CROS device in different situations. Scores were found to be significantly higher for speech understanding at some distance (p = 0.026), for speech understanding in noise (p = 0.037), for group conversations (p < 0.01), and for the overall benefit (p < 0.01) for those candidates who chose to use a Baha as a CROS device permanently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple cutaneous and uterine leiomyomata syndrome (MCUL; MIM 150800) is a rare condition that sometimes predisposes to renal cancer. It is caused by deleterious mutations in the fumarate hydratase (FH) gene. In many patients, skin leiomyomas have been reported to develop according to a segmental type 1 or type 2 distribution. We report a patient showing multiple leiomyomas distributed according to a segmental type 2 distribution and covering several areas exclusively on the left side of his body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the interobserver variability (IOV) in indicating retreatment for neovascular Age-related macular degeneration 4 weeks after three Ranibizumab loading doses using spectral domain OCT (SD-OCT) as the primary objective diagnostic tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate maxillary dental arch dimensions in pre-school children with a complete unilateral cleft lip and palate (CUCLP) after early alveolar bone grafting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loading is important to maintain the balance of matrix turnover in the intervertebral disc (IVD). Daily cyclic diurnal assists in the transport of large soluble factors across the IVD and its surrounding circulation and applies direct and indirect stimulus to disc cells. Acute mechanical injury and accumulated overloading, however, could induce disc degeneration. Recently, there is more information available on how cyclic loading, especially axial compression and hydrostatic pressure, affects IVD cell biology. This review summarises recent studies on the response of the IVD and stem cells to applied cyclic compression and hydrostatic pressure. These studies investigate the possible role of loading in the initiation and progression of disc degeneration as well as quantifying a physiological loading condition for the study of disc degeneration biological therapy. Subsequently, a possible physiological/beneficial loading range is proposed. This physiological/beneficial loading could provide insight into how to design loading regimes in specific system for the testing of various biological therapies such as cell therapy, chemical therapy or tissue engineering constructs to achieve a better final outcome. In addition, the parameter space of 'physiological' loading may also be an important factor for the differentiation of stem cells towards most ideally 'discogenic' cells for tissue engineering purpose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erratum to: Eur Spine J DOI 10.1007/s00586-011-1827-1 In the original article ‘‘Acknowledgments’’ was missing. The Acknowledgment is given below: Acknowledgments This project was supported by the Swiss National Science Foundation (SNF # 310030-127586/1) and the Department for Orthopedic Research, Insel University Hospital, Bern, Switzerland.