62 resultados para ultrasonography

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Type--Therapy (case series) Level of Evidence 4. What's known on the subject? and What does the study add? Vasectomy reversal is often performed in general or neuraxial anaesthesia. Even though the site of vasectomy reversal is easily amenable to regional/local anaesthesia, spermatic cord blocks are rarely applied because of their risk of vascular damage within the spermatic cord. Recently, we described the technique of ultrasonography (US)-guided spermatic cord block for scrotal surgery, which, thanks to the US guidance, at the same time avoids the risk of vascular damage of blindly performed injections and the risks of general and neuraxial anaesthesia. Vasectomy reversal can easily be done in regional anaesthesia with the newly described technique of US-guided spermatic cord block without the risks of vascular damage by a blindly performed injection and the risks of standard general and neuraxial anaesthesia. In addition, this technique grants long-lasting postoperative pain relief and patients recover more quickly. Microsurgical conditions are excellent and patient satisfaction is high. Thanks to these advantages, more patients undergoing vasectomy reversal might avoid general or neuraxial anaesthesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contrast-enhanced ultrasonography (CEUS) is a novel imaging technique that is safe and applicable on the bedside. Recent developments seem to enable CEUS to quantify organ perfusion. We performed an exploratory study to determine the ability of CEUS to detect changes in renal perfusion and to correlate them with effective renal plasma flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: The diagnosis of lameness caused by proximal metacarpal and metatarsal pain can be challenging. Magnetic resonance imaging (MRI) offers the possibility for further diagnosis but there have been no studies on the normal MRI appearance of the origin of the suspensory ligament (OSL) in conjunction with ultrasonography and histology. OBJECTIVES: To describe the MRI appearance of the OSL in fore- and hindlimbs of sound horses and compare it to the ultrasonographic and histological appearance. The findings can be used as reference values to recognise pathology in the OSL. METHODS: The OSL in the fore- and hindlimbs of 6 sound horses was examined by ultrasonography prior to death, and MRI and histology post mortem. Qualitative evaluation and morphometry of the OSL were performed and results of all modalities compared. RESULTS: Muscular tissue, artefacts, variable SL size and shape complicated ultrasonographic interpretation. In MRI and histology the forelimb OSL consisted of 2 portions, the lateral being significantly thicker than medial. The hindlimb SL had a single large area of origin. In fore- and hindlimbs, the amount of muscular tissue was significantly larger laterally than medially. Overall SL measurements using MRI were significantly higher than using histology and ultrasonography and histological higher than ultrasonographic measurements. Morphologically, there was a good correlation between MRI and histology. CONCLUSIONS: MRI provides more detailed information than ultrasonography regarding muscle fibre detection and OSL dimension and correlates morphologically well with histology. Therefore, ultrasonographic results should be regarded with caution. POTENTIAL RELEVANCE: MRI may be a diagnostic aid when other modalities fail to identify clearly the cause of proximal metacarpal and metatarsal pain; and may improve selection of adequate therapy and prognosis for injuries in this region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the intra-reader and inter-reader reliabilities of interpreting ultrasonography by several experts using video clips. METHOD: 99 video clips of healthy and rheumatic joints were recorded and delivered to 17 physician sonographers in two rounds. The intra-reader and inter-reader reliabilities of interpreting the ultrasound results were calculated using a dichotomous system (normal/abnormal) and a graded semiquantitative scoring system. RESULTS: The video reading method worked well. 70% of the readers could classify at least 70% of the cases correctly as normal or abnormal. The distribution of readers answering correctly was wide. The most difficult joints to assess were the elbow, wrist, metacarpophalangeal (MCP) and knee joints. The intra-reader and inter-reader agreements on interpreting dynamic ultrasound images as normal or abnormal, as well as detecting and scoring a Doppler signal were moderate to good (kappa = 0.52-0.82). CONCLUSIONS: Dynamic image assessment (video clips) can be used as an alternative method in ultrasonography reliability studies. The intra-reader and inter-reader reliabilities of ultrasonography in dynamic image reading are acceptable, but more definitions and training are needed to improve sonographic reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent development of ultrasonographic equipment has allowed improved spatial resolution for visualizing normal and pathologic conditions of peripheral nerves. Regarding the brachial plexus, only ultrasonographic studies that have described the normal appearance have been reported. To the best of our knowledge, no case report regarding the ultrasonographic description of a brachial plexus lesion has been published. We report the ultrasonographic findings of a brachial plexus injury after extirpation of a suspected enlarged supraclavicular lymph node.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Although well-established for suspected lower limb deep venous thrombosis, an algorithm combining a clinical decision score, d-dimer testing, and ultrasonography has not been evaluated for suspected upper extremity deep venous thrombosis (UEDVT). OBJECTIVE To assess the safety and feasibility of a new diagnostic algorithm in patients with clinically suspected UEDVT. DESIGN Diagnostic management study. (ClinicalTrials.gov: NCT01324037) SETTING: 16 hospitals in Europe and the United States. PATIENTS 406 inpatients and outpatients with suspected UEDVT. MEASUREMENTS The algorithm consisted of the sequential application of a clinical decision score, d-dimer testing, and ultrasonography. Patients were first categorized as likely or unlikely to have UEDVT; in those with an unlikely score and normal d-dimer levels, UEDVT was excluded. All other patients had (repeated) compression ultrasonography. The primary outcome was the 3-month incidence of symptomatic UEDVT and pulmonary embolism in patients with a normal diagnostic work-up. RESULTS The algorithm was feasible and completed in 390 of the 406 patients (96%). In 87 patients (21%), an unlikely score combined with normal d-dimer levels excluded UEDVT. Superficial venous thrombosis and UEDVT were diagnosed in 54 (13%) and 103 (25%) patients, respectively. All 249 patients with a normal diagnostic work-up, including those with protocol violations (n = 16), were followed for 3 months. One patient developed UEDVT during follow-up, for an overall failure rate of 0.4% (95% CI, 0.0% to 2.2%). LIMITATIONS This study was not powered to show the safety of the substrategies. d-Dimer testing was done locally. CONCLUSION The combination of a clinical decision score, d-dimer testing, and ultrasonography can safely and effectively exclude UEDVT. If confirmed by other studies, this algorithm has potential as a standard approach to suspected UEDVT. PRIMARY FUNDING SOURCE None.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM The effect of long-term high-intensity statin therapy on coronary atherosclerosis among patients with acute ST-segment elevation myocardial infarction (STEMI) is unknown. The aim of this study was to quantify the impact of high-intensity statin therapy on plaque burden, composition, and phenotype in non-infarct-related arteries of STEMI patients undergoing primary percutaneous coronary intervention (PCI). METHODS AND RESULTS Between September 2009 and January 2011, 103 STEMI patients underwent intravascular ultrasonography (IVUS) and radiofrequency ultrasonography (RF-IVUS) of the two non-infarct-related epicardial coronary arteries (non-IRA) after successful primary PCI. Patients were treated with high-intensity rosuvastatin (40 mg/day) throughout 13 months and serial intracoronary imaging with the analysis of matched segments was available for 82 patients with 146 non-IRA. The primary IVUS end-point was the change in per cent atheroma volume (PAV). After 13 months, low-density lipoprotein cholesterol (LDL-C) had decreased from a median of 3.29 to 1.89 mmol/L (P < 0.001), and high-density lipoprotein cholesterol (HDL-C) levels had increased from 1.10 to 1.20 mmol/L (P < 0.001). PAV of the non-IRA decreased by -0.9% (95% CI: -1.56 to -0.25, P = 0.007). Patients with regression in at least one non-IRA were more common (74%) than those without (26%). Per cent necrotic core remained unchanged (-0.05%, 95% CI: -1.05 to 0.96%, P = 0.93) as did the number of RF-IVUS defined thin cap fibroatheromas (124 vs. 116, P = 0.15). CONCLUSION High-intensity rosuvastatin therapy over 13 months is associated with regression of coronary atherosclerosis in non-infarct-related arteries without changes in RF-IVUS defined necrotic core or plaque phenotype among STEMI patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endoscopic ultrasound was developed initially in humans to overcome limitations of conventional ultrasound in examining certain internal organs due to intervening bone or air-filled structures. Endoscopic ultrasound has been used most widely in investigation of the gastrointestinal tract in humans, but many intrathoracic applications as well as endoscopic ultrasound-guided techniques have recently been described. Mediastinal and pulmonary structures can be examined with endoscopic ultrasound since a high frequency ultrasound probe can be brought into close contact with the areas of interest via a transesophageal approach. The purpose of this report is to describe the application of endoscopic ultrasound as an aid in the diagnosis of intrathoracic disease in the dog. Two dogs, one with a history of prior esophageal foreign body extraction, the other with apathy, weakness and dyspnea were referred for further investigation. Both dogs had caudal intrathoracic soft tissue opacities diagnosed radiographically, but their origin and nature were difficult to determine. Conventional ultrasound was limiting in both dogs due to their location and superimposition of gas-filled structures. With endosonography lesions were characterized more completely. We have found endoscopic ultrasound to be an elegant diagnostic tool for the investigation of radiographically detected intrathoracic lesions in the dog whose origins are difficult to determine or do not lend themselves to investigation by conventional ultrasound. Endoscopic ultrasound provides valuable diagnostic information complementary to that provided radiographically which aids in therapeutic planning. Endoscopic ultrasound was also more sensitive for detecting mediastinal lymphadenomegaly than radiography in one of the dogs. An additional advantage of endoscopic ultrasound is the fact that US-guided tissue sampling can be performed during the examination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Ultrasonographic appearance of the gastrointestinal (GI) tract of equine neonates has not been completely described. OBJECTIVES To describe (1) sonographic characteristics of the GI segments in normal nonsedated equine neonates, (2) intra- and interobserver variation in wall thickness, and (3) the sonographic appearance of asymptomatic intussusceptions, and (4) to compare age and sonographic findings of foals with and without asymptomatic intussusceptions. ANIMALS Eighteen healthy Standardbred foals ≤5 days of age. METHODS Prospective, cross-sectional blinded study. Gastrointestinal sonograms were performed stall-side. Intraobserver variability in wall thickness measurements was determined by calculating the coefficient of variation (CV). The Bland-Altman method was used to assess interobserver bias. Student's t-test and Fisher's exact test were used to test the association among presence of intussusceptions, age, and selected sonographic findings. RESULTS The reference ranges (95% predictive interval) for wall thickness were 1.6-3.6 mm for the stomach, 1.9-3.2 mm for the duodenum, 1.9-3.1 mm for the jejunum, 1.3-2.2 mm for the colon, and 0.8-2.7 mm for the cecum. Intraobserver wall thickness CV ranged from 8 to 21% for the 2 observers for 5 gastrointestinal segments. The interobserver bias for wall thickness measurements was not significant except for the stomach (0.14 mm, P < .05) and duodenum (0.29 mm, P < .05). Diagnostic images of mural blood flow could not be obtained. Asymptomatic intussusceptions were found in 10/18 neonates. Associations between sonographic variables or age and the presence of intussusceptions were not found. CONCLUSIONS AND CLINICAL IMPORTANCE Sonographic characteristics of the GI tract of normal Standardbred neonates can be useful in evaluating ill foals. Asymptomatic small intestinal intussusceptions occur in normal Standardbred neonates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. RESULTS An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CONCLUSION CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thyroid nodules are a very common clinical finding with an age-related increase in prevalence. The clinical detection of thyroid nodules is outnumbered by the ultrasonographic assessment of thyroid nodules. The clinical challenge is to exclude thyroid cancer and clinical or subclinical hyperthyroidism. Ultrasonography is the first imaging study in all patients with palpable nodules; their size and TSH determine further diagnostic evaluations. Fine-needle aspiration (cytology) is recommended in euthyroid patients of nodules measuring more than 1-1.5 cm in diameter. Nodules more than 4 cm in diameter have to be removed surgically without preceding cytological examination. Without risk factors thyroid nodules are followed by clinical examination and ultrasonography every 6-12 months, in case of symptoms or rapid growth a follow-up assessment should be done earlier.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite widespread use of imaging technologies including ultrasonography and computed tomography, rates of negative appendicectomy and perforated appendicitis remain high. This trend analysis examined whether rates of negative appendicectomy and perforated appendicitis have decreased over time, and sought to evaluate clinical predictors associated with negative appendicectomy and perforated appendicitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Musculoskeletal ultrasonography (US) is an established and validated imaging technique in rheumatology. Ultrasonography is able to directly visualize soft tissue pathologies such as synovial tissue changes. Pathological findings in superficial cartilage, bone lesions and synovial tissue changes in the context of rheumatoid arthritis, spondyloarthritis or crystal arthropathies may only be seen by sonography or detected earlier by ultrasonography compared to conventional imaging techniques. The activity of an inflammatory arthropathy can be visualized using Doppler and power Doppler US. US is helpful in the detection of early inflammatory changes, particularly in patients with undifferentiated arthritis and/or unremarkable conventional radiography. In addition to diagnosis in early arthritis and monitoring of therapy in rheumatoid arthritis, sonography is able to detect pivotal pathologies in spondyloarthritis and crystal deposition diseases such as gout, pseudogout and apatite deposition disease. Ultrasound-guided diagnostic and therapeutic interventions are characterized by their excellent accuracy and improvement of clinical effectiveness compared to unguided procedures. In conclusion, ultrasonography plays a pivotal role in the assessment and monitoring of therapy in rheumatic diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate diffusion-weighted magnetic resonance (MR) imaging of the human placenta in fetuses with and fetuses without intrauterine growth restriction (IUGR) who were suspected of having placental insufficiency. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained. The authors retrospectively evaluated 1.5-T fetal MR images from 102 singleton pregnancies (mean gestation ± standard deviation, 29 weeks ± 5; range, 21-41 weeks). Morphologic and diffusion-weighted MR imaging were performed. A region of interest analysis of the apparent diffusion coefficient (ADC) of the placenta was independently performed by two observers who were blinded to clinical data and outcome. Placental insufficiency was diagnosed if flattening of the growth curve was detected at obstetric ultrasonography (US), if the birth weight was in the 10th percentile or less, or if fetal weight estimated with US was below the 10th percentile. Abnormal findings at Doppler US of the umbilical artery and histopathologic examination of specimens from the placenta were recorded. The ADCs in fetuses with placental insufficiency were compared with those in fetuses of the same gestational age without placental insufficiency and tested for normal distribution. The t tests and Pearson correlation coefficients were used to compare these results at 5% levels of significance. RESULTS: Thirty-three of the 102 pregnancies were ultimately categorized as having an insufficient placenta. MR imaging depicted morphologic changes (eg, infarction or bleeding) in 27 fetuses. Placental dysfunction was suspected in 33 fetuses at diffusion-weighted imaging (mean ADC, 146.4 sec/mm(2) ± 10.63 for fetuses with placental insufficiency vs 177.1 sec/mm(2) ± 18.90 for fetuses without placental insufficiency; P < .01, with one false-positive case). The use of diffusion-weighted imaging in addition to US increased sensitivity for the detection of placental insufficiency from 73% to 100%, increased accuracy from 91% to 99%, and preserved specificity at 99%. CONCLUSION: Placental dysfunction associated with growth restriction is associated with restricted diffusion and reduced ADC. A decreased ADC used as an early marker of placental damage might be indicative of pregnancy complications such as IUGR.