19 resultados para total internal reflection
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We report on coherent spatiotemporal imaging of single-cycle THz waves in frustrated total internal reflection geometry. Our technique yields images of the spatiotemporal electric field distribution before and after tunneling through an air gap in between two LiNbO3 crystals. Measurements of the reflected and the transmitted THz waveforms for different tunnel distances allow for a direct comparison with results from a causal linear dispersion theory and excellent agreement is found.
Resumo:
Hypomagnesemia affects insulin resistance and is a risk factor for diabetes mellitus type 2 (DM2) and gestational diabetes mellitus (GDM). Two single nucleotide polymorphisms (SNPs) in the epithelial magnesium channel TRPM6 (V(1393)I, K(1584)E) were predicted to confer susceptibility for DM2. Here, we show using patch clamp analysis and total internal reflection fluorescence microscopy, that insulin stimulates TRPM6 activity via a phosphoinositide 3-kinase and Rac1-mediated elevation of cell surface expression of TRPM6. Interestingly, insulin failed to activate the genetic variants TRPM6(V(1393)I) and TRPM6(K(1584)E), which is likely due to the inability of the insulin signaling pathway to phosphorylate TRPM6(T(1391)) and TRPM6(S(1583)). Moreover, by measuring total glycosylated hemoglobin (TGH) in 997 pregnant women as a measure of glucose control, we demonstrate that TRPM6(V(1393)I) and TRPM6(K(1584)E) are associated with higher TGH and confer a higher likelihood of developing GDM. The impaired response of TRPM6(V(1393)I) and TRPM6(K(1584)E) to insulin represents a unique molecular pathway leading to GDM where the defect is located in TRPM6.
Resumo:
The Microwave Emission Model of Layered Snowpacks (MEMLS) was originally developed for microwave emissions of snowpacks in the frequency range 5–100 GHz. It is based on six-flux theory to describe radiative transfer in snow including absorption, multiple volume scattering, radiation trapping due to internal reflection and a combination of coherent and incoherent superposition of reflections between horizontal layer interfaces. Here we introduce MEMLS3&a, an extension of MEMLS, which includes a backscatter model for active microwave remote sensing of snow. The reflectivity is decomposed into diffuse and specular components. Slight undulations of the snow surface are taken into account. The treatment of like- and cross-polarization is accomplished by an empirical splitting parameter q. MEMLS3&a (as well as MEMLS) is set up in a way that snow input parameters can be derived by objective measurement methods which avoid fitting procedures of the scattering efficiency of snow, required by several other models. For the validation of the model we have used a combination of active and passive measurements from the NoSREx (Nordic Snow Radar Experiment) campaign in Sodankylä, Finland. We find a reasonable agreement between the measurements and simulations, subject to uncertainties in hitherto unmeasured input parameters of the backscatter model. The model is written in Matlab and the code is publicly available for download through the following website: http://www.iapmw.unibe.ch/research/projects/snowtools/memls.html.
Resumo:
By measuring the total crack lengths (TCL) along a gunshot wound channel simulated in ordnance gelatine, one can calculate the energy transferred by a projectile to the surrounding tissue along its course. Visual quantitative TCL analysis of cut slices in ordnance gelatine blocks is unreliable due to the poor visibility of cracks and the likely introduction of secondary cracks resulting from slicing. Furthermore, gelatine TCL patterns are difficult to preserve because of the deterioration of the internal structures of gelatine with age and the tendency of gelatine to decompose. By contrast, using computed tomography (CT) software for TCL analysis in gelatine, cracks on 1-cm thick slices can be easily detected, measured and preserved. In this, experiment CT TCL analyses were applied to gunshots fired into gelatine blocks by three different ammunition types (9-mm Luger full metal jacket, .44 Remington Magnum semi-jacketed hollow point and 7.62 × 51 RWS Cone-Point). The resulting TCL curves reflected the three projectiles' capacity to transfer energy to the surrounding tissue very accurately and showed clearly the typical energy transfer differences. We believe that CT is a useful tool in evaluating gunshot wound profiles using the TCL method and is indeed superior to conventional methods applying physical slicing of the gelatine.
Resumo:
PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.
Resumo:
To support development tools like debuggers, runtime systems need to provide a meta-programming interface to alter their semantics and access internal data. Reflective capabilities are typically fixed by the Virtual Machine (VM). Unanticipated reflective features must either be simulated by complex program transformations, or they require the development of a specially tailored VM. We propose a novel approach to behavioral reflection that eliminates the barrier between applications and the VM by manipulating an explicit tower of first-class interpreters. Pinocchio is a proof-of-concept implementation of our approach which enables radical changes to the interpretation of programs by explicitly instantiating subclasses of the base interpreter. We illustrate the design of Pinocchio through non-trivial examples that extend runtime semantics to support debugging, parallel debugging, and back-in-time object-flow debugging. Although performance is not yet addressed, we also discuss numerous opportunities for optimization, which we believe will lead to a practical approach to behavioral reflection.
Resumo:
PRINCIPLES: Coeliac disease (gluten sensitive enteropathy) is a genetically determined disorder with an incidence in the general population that is comparable to type 2 diabetes mellitus. Awareness of this fact and of the often atypical and oligosymptomatic manifestations is only now gaining ground in the medical profession. A high index of suspicion is important in order to minimise diagnostic and therapeutic delay. METHODS: Testing patterns and follow-up for coeliac disease in our institution have been analysed retrospectively for the past five years. The current literature was reviewed with respect to recommendations for clinical practice. RESULTS: A total of 271 patients were tested for coeliac disease over a period of five years. Only in 24 patients were positive results found; after further work-up, the final number of cases with certain or presumed coeliac disease was four. Followup was often difficult, many patients being lost after a single visit. CONCLUSIONS: This study showed that the number of tests ordered in our institution, more often for abdominal than atypical symptoms, has started to increase in the past two years. It also showed that screening tests have found their place in general clinical practice, while the final choice of tests needs to be determined in accordance with available guidelines and local resources. Upper endoscopy with small bowel biopsy remains the gold standard for diagnosis, but its place in follow-up is less certain. Coeliac disease is a disorder for which there is a definite treatment (gluten free diet); if it is left untreated diminished quality of life and potentially serious complications may ensue. Further education of the medical profession regarding coeliac disease, its incidence, presentation and treatment, is clearly indicated..
Resumo:
BACKGROUND: The remarkable patency of internal mammary artery (MA) grafts compared to saphenous vein (SV) grafts has been related to different biological properties of the two blood vessels. We examined whether proliferation and apoptosis of vascular smooth muscle cells (VSMC) from human coronary artery bypass vessels differ according to patency rates. METHODS AND RESULTS: Proliferation rates to serum or platelet-derived growth factor (PDGF)-BB were lower in VSMC from MA than SV. Surface expression of PDGF beta-receptor was slightly lower, while that of alpha-receptor was slightly higher in MA than SV. Cell cycle distribution, expression of cyclin E, cdk2, p21, p27, p57, and cdk2 kinase activity were identical in PDGF-BB-stimulated cells from MA and SV. However, apoptosis rates were higher in MA than SV determined by lactate dehydrogenase release, DNA fragmentation, and Hoechst 33258 staining. Moreover, caspase inhibitors (Z-VAD-fmk, Boc-D-fmk) abrogated the different proliferation rates of VSMC from MA versus SV. Western blotting and GSK3-beta kinase assay revealed lower Akt activity in VSMC from MA versus SV, while total Akt expression was identical. Adenoviral transduction of a constitutively active Akt mutant abrogated the different proliferation rates of VSMC from MA versus SV. CONCLUSIONS: Higher apoptosis rates due to lower Akt activity rather than different cell cycle regulation account for the lower proliferation of VSMC from MA as compared to SV. VSMC apoptosis may protect MA from bypass graft disease.
Resumo:
Individual monitoring regulations in Switzerland are based on the ICRP60 recommendations. The annual limit of 20 mSv for the effective dose applies to the sum of external and internal radiation. External radiation is monitored monthly or quarterly with TLD, DIS or CR-39 dosemeters by 10 approved external dosimetry services and reported as H(p)(10) and H(p)(0.07). Internal monitoring is done in two steps. At the workplace, simple screening measurements are done frequently in order to recognise a possible incorporation. If a nuclide dependent activity threshold is exceeded then one of the seven approved dosimetry services for internal radiation does an incorporation measurement to assess the committed effective dose E(50). The dosimetry services report all the measured or assessed dose values to the employer and to the National Dose Registry. The employer records the annually accumulated dose values into the individual dose certificate of the occupationally exposed person, both the external dose H(p)(10) and the internal dose E(50) as well as the total effective dose E = H(p)(10)+E(50). Based on the national dose registry an annual report on the dosimetry in Switzerland is published which contains the statistics for the total effective dose, as well as separate statistics for external and internal exposure.
Resumo:
BACKGROUND: Increasing age and comorbidities among patients undergoing coronary artery bypass surgery (CABG) stimulates the exhaustive research for alternative grafts. No-React treatment should render the tissue resistant against degeneration and reduce early inflammatory response. The aim of the present study was an invasive assessment of the patency of No-React bovine internal mammary artery (NRIMA grafts) used as bypass conduit in CABG surgery. PATIENTS AND METHODS: Nineteen NRIMA grafts were used in 17 patients (2.9%) out of a total of 572 patients undergoing CABG surgery within a 12-month period. All intraoperative data were assessed and in-hospital outcome was analysed. Follow-up examination was performed 7.0+/-4.0 months after initial surgery, including clinical status and coronary angiography to assess patency of the NRIMA grafts. RESULTS: Average perioperative flow of all NRIMA grafts was 71+/-60 ml/min. One patient died in hospital due to a multi-organ failure. Four patients refused invasive assessment. Follow-up was complete in 12 patients with overall 13 NRIMA grafts. Nine NRIMA grafts (69.2%) were used for the right coronary system, two NRIMA grafts (15.4%) on the LAD and two on the circumflex artery. Graft patency was 23.1% and was independent of the intraoperative flow measurement. CONCLUSIONS: NRIMA grafts show a very low patency and cannot be recommended as coronary bypass graft conduits. Patency was independent of the perioperative flow, assessed by Doppler ultrasound. Because of this unsatisfying observation, this type of graft should be utilised as a last resource conduit and used only to revascularise less important target vessels, such as the end branches of the right coronary artery.
Resumo:
Notwithstanding non-robotic, thoracoscopic preparation of the internal mammary artery (IMA) is a difficult surgical task, an appropriate experimental training model is lacking. We evaluated the young domestic pig for this purpose. Four domestic female pigs (30-40 kg body weight) were used for this study. Bilateral thoracoscopic preparation of the IMA was carried out under continuous, pressure controlled CO(2) insufflation. A 30 degrees rigid thoracoscope was inserted through a 10-mm port in the 5th/6th intercostal space (ICS) dorsally to the posterior axillary line. The dissection instrument (Ultracision Harmonic Scalpel) was inserted (5-mm port) in the 7th ICS at the posterior axillary line and the endo-forceps (5-mm port) in the 5th ICS at the posterior axillary line. Thoracoscopic IMA preparation in pig resulted more difficult than in man. A total of seven IMAs were prepared in their full intrathoracic length. A change in the preparation technique (lateral detachment of the endothoracic muscle) improved the safety of the procedure, allowing all four respective IMAs to be prepared safely, while the initial technique ensued an injury for 2 out of 3 vessels. The described young domestic pig model is suitable for experimental training of bilateral thoracoscopic IMA preparation.
Resumo:
Acetabular retroversion following acetabular osteotomy in hips with dysplasia can negatively effect the outcome. Total retroversion, where the entire anterior rim is lateral to the posterior rim, is rare and can easily be missed on pelvic radiographs due to the lack of a crossover sign. We evaluated the clinical and radiographic presentation, the surgical management, and the outcome of hips with total acetabular retroversion. We retrospectively reviewed 26 patients (26 hips) with total retroversion following 15 periacetabular osteotomies (PAO), 10 triple type, and one Salter osteotomy. We obtained range of motion (ROM), anterior impingement test, Drehmann's sign, Merle d’Aubigné-Postel score, and Tönnis score for osteoarthrosis. Corrective surgery included 19 revision PAOs and seven total hip arthroplasties (THA). The mean follow-up was 4.7 ± 4.2 (range 0.5-13.8) years. Patients presented with a restricted ROM (flexion and internal rotation), a positive anterior impingement test, a positive Drehmann's sign, and a decreased Merle d'Aubigné-Postel score due to pain. Corrective surgery was performed after mean of 7 ± 5 (1-15) years. Complications for revision PAO and THA occurred in 37% and 29%, respectively. At follow-up, the Merle d'Aubigné-Postel score improved for both revision PAOs and THAs. The prevalence of a positive anterior impingement test and Drehmann's sign decreased for revision PAOs. There was a tendency for progression of OA in hips with revision PAO. Iatrogenic total acetabular retroversion following reorientation is a disabling condition for the patients. Corrective surgery including revision PAO and THA results in improved clinical outcome. However, these procedures are technically challenging and associated with high complication rates.
Resumo:
Objectives: We compare the dose parameters between 3 different radiosurgery delivery techniques which may have an impact on cochlea function. Methods: Five patients with unilateral vestibular schwannoma (VS) were selected for this study. Planning procedure was carried out using the BrainLAB® iPlan planning system v. 4.5. For each patient three different planning techniques were used: dynamic arc (DA) with 5 arcs per plan, hybrid arc (HA) with 5 arcs per plan and IMRT with 8 fields per plan. For each technique, two plans were generated with different methods: with the first method (PTV coverage) it was the goal to fully cover the PTV with at least 12 Gy (normalization: 12 Gy covered 99% of the PTV) and with the second method (cochlea sparing) it was the goal to spare the cochlea (normalization: 12 Gy covers 50% of the PTV/V4Gy of cochlea lower than 1%). Plan evaluation was done considering target volume and coverage (conformity and homogeneity) and OAR constraints (mean (Dmean) and maximum dose (Dmax) to cochlea, Dmax to brainstem and cochlea). The total number of monitor units (MU) was analyzed. Results: The median tumor volume was 0.95 cm³ (range, 0.86-3 cm³). The median PTV was 1.44 cm³ (range, 1-3.5 cm³). The median distance between the tumor and the cochlea's modiulus was 2.7 mm (range, 1.8-6.3 mm). For the PTV coverage method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.872) and in Dmean (p= 0.860). We found a significant correlation (p< 0.05) between the target volume and the cochlear Dmean for all plans with Pearson's coefficient correlation of 0.90, 0.92 and 0.94 for the DA, HA and IMRT techniques, respectively. For the cochlea sparing method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.310) and in Dmean (p= 0.275). However, in this group the V4Gy of the ipsilateral cochlea represents less than 1%. When using the HA or IMRT technique, the homogeneity and conformity in the PTV, but also the number of MUs were increased in comparison to the DA technique. Conclusion: VS tumors that extend distally into the IAC had an equivalent sparing of cochlea with DA approach compared with the HA and IMRT techniques. Disclosure: No significant relationships.
Resumo:
BACKGROUND The function of naturally existing internal mammary (IMA)-to-coronary artery bypasses and their quantitative effect on myocardial ischemia are unknown. METHODS AND RESULTS The primary end point of this study was collateral flow index (CFI) obtained during two 1-minute coronary artery balloon occlusions, the first with and the second without simultaneous distal IMA occlusion. The secondary study end point was the quantitatively determined intracoronary ECG ST-segment elevation. CFI is the ratio of simultaneously recorded mean coronary occlusive pressure divided by mean aortic pressure both subtracted by mean central venous pressure. A total of 180 pairs of CFI measurements were performed among 120 patients. With and without IMA occlusion, CFI was 0.110±0.074 and 0.096±0.072, respectively (P<0.0001). The difference of CFI obtained in the presence minus CFI obtained in the absence of IMA occlusion was highest and most consistently positive during left IMA with left anterior descending artery occlusion and during right IMA with right coronary artery occlusion (ipsilateral occlusions): 0.033±0.044 and 0.025±0.027, respectively. This CFI difference was absent during right IMA with left anterior descending artery occlusion and during left IMA with right coronary artery occlusion (contralateral occlusions): -0.007±0.034 and 0.001±0.023, respectively (P=0.0002 versus ipsilateral occlusions). The respective CFI differences during either IMA with left circumflex artery occlusion were inconsistently positive. Intracoronary ECG ST-segment elevations were significantly reduced during ipsilateral IMA occlusions but not during contralateral or left circumflex artery occlusions. CONCLUSION There is a functional, ischemia-reducing extracardiac coronary artery supply via ipsilateral but not via contralateral natural IMA bypasses. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCTO1676207.
Resumo:
PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.