5 resultados para tip leakage flow

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To study the effects of a milking system that partially compensates for milk flow-dependent vacuum loss compared with a standard (high-line) milking unit in a tie-stall barn, milk flow and vacuum patterns were recorded in 10 cows during machine milking with 2 milking systems in a crossover design for 7 d each. Before and after each treatment period postmilking teat condition was recorded by ultrasound cross-sectioning. Additionally, 2 methods to measure teat tissue condition were compared: longitudinal teat ultrasound cross-sectioning and teat tissue density measurements with the spring-loaded caliper (cutimeter method). The partial compensation of milk flow-dependent vacuum loss caused an elevation of the peak flow rate (4.74+/-0.08 vs. 4.29+/-0.07 kg/min) and a shorter duration of plateau (1.57+/-0.06 vs. 1.96+/-0.07 min) compared with the standard milking system. Total milk yield, duration of incline and decline of milk flow, average milk flow, time until peak flow rate, main milking time, and total milking time did not differ between treatments (overall means: 13.75+/-0.17 kg; 0.65+/-0.01 min; 2.88+/-0.09 min; 2.82+/-0.05 kg/min; 1.65+/-0.03 min; 5.23+/-0.09 min, and 5.30+/-0.10 min, respectively). The vacuum drop in the short milk tube during periods of high milk flow was less in the compensating vacuum than in the standard milking system (11+/-1.1 vs. 15+/-0.7 kPa). Teat measures as determined by ultrasound remained unchanged over the entire experimental period with both milking systems. Postmilking teat tissue measures including their recovery within 20 min after the end of milking show a correlation (0.85 and 0.71, respectively) between the methods used (ultrasound and cutimeter method). In conclusion, a more constant vacuum at the teat tip (within the short milk tube) during periods of high milk flow affected milk flow patterns, mainly increasing peak flow rate. However, the reduced vacuum loss did not increase the overall speed of milking. In addition, effects of higher vacuum stability on teat condition and udder health were not obvious.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Incontinentia lactis is a possible predisposing factor for an elevated level of intramammary infection. The goal of the present study was to investigate possible causes of incontinentia lactis in dairy cows. Two farms that differed in breed composition, but that had similar average milk yields were studied: herd A, 28 kg/d, 31 Red Holstein cows; and herd B, 26 kg/d, 16 Brown Swiss cows. Herd A was classified into 2 groups: incontinentia lactis (ILA group) and control, whereas herd B was exclusively a control herd. Milk samples that represented foremilk and the main milk fraction were collected during 4 milking sessions. In addition, milk leakage samples from the ILA group were collected at different time intervals from 0 to 5 h before milking. Measurements of the teat, milk flow, fractions of cisternal and alveolar milk, intramammary pressure, and blood oxytocin pattern also were obtained. The ILA cows did not have differences in fat content between milk leakage and cisternal milk fraction. Milk fat content, however, increased during milking in response to continuous milk ejection (1.95, 1.99, and 4.61% for milk leakage, cisternal, and main milk samples, respectively). Teat canals were 9% shorter in the ILA cows, which showed greater milk yield, peak, and average flow rates. Quarter cisternal milk yield of ILA cows tended to be greater (0.50 vs. 0.23 and 0.28 kg for ILA and controls from herds A and B, respectively), whereas percentages of cistern milk and alveolar milk did not differ from controls. The greater pressure in the ILA group, both before and after manual udder stimulation (ILA: 4.0 and 6.4 kPa; control: 2.0 and 5.0 kPa, respectively), could be an important cause for the leakage. Nevertheless, the increase in IMP that occurred after udder preparation affirms that milk ejection occurred in response to the tactile teat stimulation, but not before the onset of leakage. Blood oxytocin concentration in ILA cows was low until the start of udder preparation and increased in response to the milking stimulus (reaffirming the hypothesis that milk leakage occurred in the absence of milk ejection). In conclusion, milk losses by leakage are likely due to the large amount of cisternal milk, which creates pressure and causes leakage, in the absence of milk ejection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STUDY DESIGN: This is an experimental study on an artificial vertebra model and human cadaveric spine. OBJECTIVE: Characterization of polymethylmethacrylate (PMMA) bone cement distribution in the vertebral body as a function of cement viscosity, bone porosity, and injection speed. Identification of relevant parameters for improved cement flow predictability and leak prevention in vertebroplasty. SUMMARY OF BACKGROUND DATA: Vertebroplasty is an efficient procedure to treat vertebral fractures and stabilize osteoporotic bone in the spine. Severe complications result from bone cement leakage into the spinal canal or the vascular system. Cement viscosity has been identified as an important parameter for leak prevention but the influence of bone structure and injection speed remain obscure. METHODS: An artificial vertebra model based on open porous aluminum foam was used to simulate bone of known porosity. Fifty-six vertebroplasties with 4 different starting viscosity levels and 2 different injection speeds were performed on artificial vertebrae of 3 different porosities. A validation on a human cadaveric spine was executed. The experiments were radiographically monitored and the shape of the cement clouds quantitatively described with the 2 indicators circularity and mean cement spreading distance. RESULTS: An increase in circularity and a decrease in mean cement spreading distance was observed with increasing viscosity, with the most striking change occurring between 50 and 100 Pas. Larger pores resulted in significantly reduced circularity and increased mean cement spreading distance whereas the effect of injection speed on the 2 indicators was not significant. CONCLUSION: Viscosity is the key factor for reducing the risk of PMMA cement leakage and it should be adapted to the degree of osteoporosis encountered in each patient. It may be advisable to opt for a higher starting viscosity but to inject the material at a faster rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to evaluate irrigated-tip catheter for ablation of intraatrial reentrant tachycardias late after surgical repair of congenital heart disease. BACKGROUND In congenital heart disease patients, the right atrium can be markedly enlarged with areas of low blood flow. Radiofrequency (RF) lesion creation may be hampered by insufficient electrode cooling at sites with low blood flow. METHODS Thirty-six consecutive patients with intraatrial reentrant tachycardia refractory to antiarrhythmic therapy from two centers were included in the study. Entrainment pacing and electroanatomic mapping (CARTO) were used to delineate reentrant circuits and critical isthmus sites. RF ablation was performed using an irrigated-tip catheter (Navistar Thermocool). RESULTS Fifty-two intraatrial reentrant tachycardia circuits were identified, and 48 were targeted with RF ablation. RF ablation was performed using a mean of 13 +/- 11 irrigated RF applications per tachycardia isthmus with a mean power of 36 +/- 8 W. In a historical control group of congenital heart disease patients managed with conventional catheter ablation, the number of lesions per isthmus was higher (23 +/- 11) and mean power was lower (27 +/- 14 W). Acute success was achieved in 45 intraatrial reentrant tachycardias (94% of targeted tachycardias and 87% of all tachycardias). After a mean follow-up of 17 +/- 7 months, 33 (92%) of 36 patients were free of recurrence. Five patients (14%) developed paroxysmal atrial fibrillation. CONCLUSIONS The combination of modern techniques including electroanatomic mapping and catheter irrigation allows safe and highly effective ablation of intraatrial reentrant tachycardia in patients with surgically repaired congenital heart disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE We sought to evaluate the feasibility of k-t parallel imaging for accelerated 4D flow MRI in the hepatic vascular system by investigating the impact of different acceleration factors. MATERIALS AND METHODS k-t GRAPPA accelerated 4D flow MRI of the liver vasculature was evaluated in 16 healthy volunteers at 3T with acceleration factors R = 3, R = 5, and R = 8 (2.0 × 2.5 × 2.4 mm(3), TR = 82 ms), and R = 5 (TR = 41 ms); GRAPPA R = 2 was used as the reference standard. Qualitative flow analysis included grading of 3D streamlines and time-resolved particle traces. Quantitative evaluation assessed velocities, net flow, and wall shear stress (WSS). RESULTS Significant scan time savings were realized for all acceleration factors compared to standard GRAPPA R = 2 (21-71 %) (p < 0.001). Quantification of velocities and net flow offered similar results between k-t GRAPPA R = 3 and R = 5 compared to standard GRAPPA R = 2. Significantly increased leakage artifacts and noise were seen between standard GRAPPA R = 2 and k-t GRAPPA R = 8 (p < 0.001) with significant underestimation of peak velocities and WSS of up to 31 % in the hepatic arterial system (p <0.05). WSS was significantly underestimated up to 13 % in all vessels of the portal venous system for k-t GRAPPA R = 5, while significantly higher values were observed for the same acceleration with higher temporal resolution in two veins (p < 0.05). CONCLUSION k-t acceleration of 4D flow MRI is feasible for liver hemodynamic assessment with acceleration factors R = 3 and R = 5 resulting in a scan time reduction of at least 40 % with similar quantitation of liver hemodynamics compared with GRAPPA R = 2.