29 resultados para tightening torque
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Prediction of dental implant torque with a fast and automatic finite element analysis: a pilot study
Resumo:
Despite its importance, implant removal torque can be assessed at present only after implantation. This paper presents a new technique to help clinicians preoperatively evaluate implant stability.
Resumo:
The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.
Resumo:
The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.
Resumo:
OBJECTIVE To compare the archwires inserted during the final stages of the orthodontic treatment with the generated moments at 0.018- and 0.022-inch brackets. MATERIALS AND METHODS The same bracket type, in terms of prescription, was evaluated in both slot dimensions. The brackets were bonded on two identical maxillary acrylic resin models, and each model was mounted on the orthodontic measurement and simulation system. Ten 0.017 × 0.025-inch TMA and ten 0.017 × 0.025-inch stainless steel archwires were evaluated in the 0.018-inch brackets. In the 0.022-inch brackets, ten 0.019 × 0.025-inch TMA and ten 0.019 × 0.025-inch stainless steel archwires were measured. A 15° buccal root torque (+15°) and then a 15° palatal root torque (-15°) were gradually applied to the right central incisor bracket, and the moments were recorded at these positions. A t-test was conducted to compare the generated moments between wires within the 0.018- and 0.022-inch bracket groups separately. RESULTS The 0.017 × 0.025-inch archwire in the 0.018-inch brackets generated mean moments of 9.25 Nmm and 14.2 Nmm for the TMA and stainless steel archwires, respectively. The measured moments in the 0.022-inch brackets with the 0.019 × 0.025-inch TMA and stainless steel archwires were 6.6 Nmm and 9.3 Nmm, respectively. CONCLUSION The 0.017 × 0.025-inch stainless steel and β-Ti archwires in the 0.018-inch slot generated higher moments than the 0.019 × 0.025-inch archwires because of lower torque play. This difference is exaggerated in steel archwires, in comparison with the β-Ti, because of differences in stiffness. The differences of maximum moments between the archwires of the same cross-section but different alloys were statistically significant at both slot dimensions.
Resumo:
PURPOSE To enhance the diminished screw purchase in cancellous, osteoporotic bone following the fixation of posterior pelvic ring injuries by iliosacral screws an increased bone-implant contact area using modificated screws, techniques or bone cement may become necessary. The aim of the study was to identify sites within the pathway of iliosacral screws requiring modifications of the local bone or the design of instrumentations placed at this site. MATERIALS AND METHODS The breakaway torque was measured mechanically at the iliosacral joint ("ISJ"), the sacral lateral mass ("SLM") and the center of the S1 ("CS1"), at a superior and an inferior site under fluoroscopic control on five human cadaveric specimens (3 female; mean age 87 years, range: 76-99) using the DensiProbe™Spine device. RESULTS The measured median (range) breakaway torque was 0.63 Nm (0.31-2.52) at the "iliosacral joint", 0.14 Nm (0.05-1.22) at the "sacral lateral mass", 0.57 Nm (0.05-1.42) at the "S1 center." The "sacral lateral mass" breakaway torque was lower than compared to that at the "iliosacral joint" (p < .001) or "S1 center" (p < .001). The median (range) breakaway torque measured at all superior measurement points was 0.52 Nm (0.10-2.52), and 0.48 Nm (0.05-1.18) at all inferior sites. The observed difference was statistically significant (p < .05). CONCLUSIONS The lateral mass of the sacrum provides the lowest bone quality for implant anchorage. Iliosacral screws should be placed as superior as safely possible, should bridge the iliosacral joint and may allow for cement application at the lateral mass of the sacrum through perforations.
Resumo:
Abstract Objectives: To investigate the influence of protein incorporation on the resistance of biomimetic calcium-phosphate coatings to the shear forces that are generated during implant insertion. Materials and Methods: Thirty-eight standard (5 x 13 mm) Osseotite((R)) implants were coated biomimetically with a layer of calcium phosphate, which either lacked or bore a co-precipitated (incorporated) depot of the model protein bovine serum albumin (BSA). The coated implants were inserted into either artificial bone (n=18) or the explanted mandibles of adult pigs (n=12). The former set-up was established for the measurement of torque and of coating losses during the insertion process. The latter set-up was established for the histological and histomorphometric analysis of the fate of the coatings after implantation. Results: BSA-bearing coatings had higher mean torque values than did those that bore no protein depot. During the insertion process, less material was lost from the former than from the latter type of coating. The histological and histomorphometric analysis revealed fragments of material to be sheared off from both types of coating at vulnerable points, namely, at the tips of the threads. The sheared-off fragments were retained within the peri-implant space. Conclusion: The incorporation of a protein into a biomimetically prepared calcium-phosphate coating increases its resistance to the shear forces that are generated during implant insertion. In a clinical setting, the incorporated protein would be an osteogenic agent, whose osteoinductive potential would not be compromised by the shearing off of coating material, and the osteoconductivity of an exposed implant surface would not be less than that of a coated one. To cite this article: Hägi TT, Enggist L, Michel D, Ferguson SJ, Liu Y, Hunziker EB. Mechanical insertion properties of calcium-phosphate implant coatings. Clin. Oral Impl. Res. xx, 2010; 000-000. doi: 10.1111/j.1600-0501.2010.01916.x.
Resumo:
STUDY DESIGN.: Cadaver study. OBJECTIVE.: To determine bone strength in vertebrae by measuring peak breakaway torque or indentation force using custom-made pedicle probes. SUMMARY OF BACKGROUND DATA.: Screw performance in dorsal spinal instrumentation is dependent on bone quality of the vertebral body. To date no intraoperative measuring device to validate bone strength is available. Destructive testing may predict bone strength in transpedicular instrumentations in osteoporotic vertebrae. Insertional torque measurements showed varying results. METHODS.: Ten human cadaveric vertebrae were evaluated for bone mineral density (BMD) measurements by quantitative computed tomography. Peak torque and indentation force of custom-made probes as a measure for mechanical bone strength were assessed via a transpedicular approach. The results were correlated to regional BMD and to biomechanical load testing after pedicle screw implementation. RESULTS.: Both methods generated a positive correlation to failure load of the respective vertebrae. The correlation of peak breakaway torque to failure load was r = 0.959 (P = 0.003), therewith distinctly higher than the correlation of indentation force to failure load, which was r = 0.690 (P = 0.040). In predicting regional BMD, measurement of peak torque also performed better than that of indentation force (r = 0.897 [P = 0.002] vs. r = 0.777 [P = 0.017]). CONCLUSION.: Transpedicular measurement of peak breakaway torque is technically feasible and predicts reliable local bone strength and implant failure for dorsal spinal instrumentations in this experimental setting.
Resumo:
For nonsurgical treatment of fractures of the proximal phalanges of the triphalangeal fingers, different dynamic casts have been described. The main principle behind these casts is advancement and tightening of the extensor hood, caused by a combination of blocking the metacarpophalangeal joints in flexion and actively flexing the proximal interphalangeal joints. In contrast to established treatment protocols using functional forearm casts, the Lucerne cast allows for free mobilization of the wrist joint. The purpose of the current multicenter study was to compare the results of conservative, functional treatment using 2 different methods, either a forearm cast or a Lucerne cast.
Resumo:
Since the first studies by Apfelberg in 1994, laser lipolysis (LAL) has been on the rise. Laser lipolysis leads to reduced operator fatigue, excellent patient tolerance, quick recovery time, as well as the additional benefit of dermal tightening. This article reports a 5-year experience of LAL and underlines the potential evolutions of the technique.
Resumo:
Gynecomastia is the most common breast pathology. Numerous excisions and liposuction techniques have been described to correct bilateral male breast enlargement. Recently, there has been a shift from the open approach to minimally invasive techniques. This article reports a 5-year experience using laser-assisted lipolysis (LAL) to treat gynecomastia, and describes the surgical technique. Between January 2006 and December 2010, a total of 28 patients with bilateral gynecomastia were treated with LAL. Patients had a mean age of 36.5 years (range 24 to 56 years). LAL was performed with a 980-nm diode laser (continuous emission, 15 W power, 8-12 kJ total energy per breast) after tumescent anesthetic infiltration. The breast was evaluated objectively by two physicians who compared chest circumference and photographs. Patients were also asked to score the results using a visual analogue scale: 75 to 100 (very good), 50-74 (good), 25 to 49 (fair) and 0 to 24 (poor). The postoperative period for all patients was incident-free. After 6 months, 18 patients (64.3%) scored the results as "very good", 6 as "good" (21.4%), 3 as "fair" (10.7%) and 1 "poor" (3.6%). Mean chest circumferences pre- and postoperatively were, respectively, 117.4 ± 11.1 cm and 103.3 ± 7.5 cm (p < 0.001), corresponding to a mean difference of 14.1 cm. Physicians scored the photographs as "very good" in 22 patients (78.6%), as "good" in five patients (17.9%), and as "fair" in one patient (3.6%). LAL in gynecomastia is safe and produces significant effects on fatty tissue, with a reduction in breast volume, together with significant skin tightening. Provided an appropriate amount of energy is delivered by an experienced operator, the results are both significant and consistent.
Resumo:
Nowadays surgical intervention is an essential part of the treatment of idiopathic gynecomastia. Choosing the right method is crucial and is based on the current status in the clinical and histological evaluation. Before finalizing the process of choosing a specific method a prior interdisciplinary evaluation of the patient is necessary to ascertain clear indications for a surgical intervention. Liposuction is one of the methods which have become popular in recent years. The advantages are the possible combination with traditional techniques, such as subcutaneous mastectomy or periareolar mastopexy. The main indication is for gynecomastia stage IIa/b and is justifiable due to the reduction in surgical complications and scarring. Furthermore this technique provides an excellent aesthetical outcome for the patient. A total of 162 patients suffering from gynecomastia stages I-III (according to Simon) were surgically treated between 2000 and 2010 and these cases were retrospectively evaluated. The results showed a decline in the use of a T-shaped incision in combination with subcutaneous mastectomy with periareolar tightening compared to an increase in the use of subcutaneous mastectomy in combination with liposuction. The excised tissue should always be sent for histological examination to make sure no malignant cells were present.
Resumo:
Bonding a flexible spiral wire retainer to the lingual surfaces of all 6 anterior mandibular teeth is a commonly used type of retention. Complications are rare but can be serious enough to produce biologic damage. This article presents a serious complication of a lingual flexible spiral wire retainer. Four years after the orthodontic treatment, a 20-year-old man sought treatment for a broken flexible spiral wire retainer. The clinical examination showed about 35° of buccal root torque of that tooth. A cone-beam computed tomography image showed that the root and the apex of the tooth were almost completely out of the bone on its buccal side. Surprisingly, the tooth's vitality was preserved. The tooth was moved back, nearly to its original position; clinically, only a gingival recession remained. Orthodontists and dentists should be aware of possible complications of bonded retainers. Patients should be clearly informed how to detect problems at an early stage.
Resumo:
The aim of this study was to evaluate the survival and success rates of immediately restored implants with sandblasted, large-grit, acid-etched (SLA) surfaces over a period of 5 years. Twenty patients (mean age, 47.3 years) received a total of 21 SLA wide-neck implants in healed mandibular first molar sites after initial periodontal treatment. To be included in the study, the implants had to demonstrate primary stability with an insertion torque value of 35 Ncm. A provisional restoration was fabricated chairside and placed on the day of surgery. Definitive cemented restorations were inserted 8 weeks after surgery. Community Periodontal Index of Treatment Needs (CPITN) indices and the radiographic distance between the implant shoulder and the first visible bone-implant contact (DIB) were measured and compared over the study period. The initial mean CPITN was 3.24, and decreased over the study period to 1.43. At the postoperative radiographic examination, the mean DIB was 1.41 mm for the 21 implants, indicating that part of the machined neck of the implants was placed slightly below the osseous crest. The mean DIB value increased to 1.99 mm at the 5-year examination. This increase proved to be statistically significant (P < .0001). Between the baseline and 5-year examinations, the mean bone crest level loss was 0.58 mm. Success and survival rates of the 21 implants after 5 years of function were 100%. This 5-year study confirms that immediate restoration of mandibular molar wide-neck implants with good primary stability, as noted by insertion torque values of at least 35 Ncm, is a safe and predictable procedure.
Resumo:
Enhancing osseointegration through surface immobilization of multiple short peptide sequences that mimic extracellular matrix (ECM) proteins, such as arginine-glycine-aspartic acid (RGD) and lysine-arginine-serine-arginine (KRSR), has not yet been extensively explored. Additionally, the effect of biofunctionalizing chemically modified sandblasted and acid-etched surfaces (modSLA) is unknown. The present study evaluated modSLA implant surfaces modified with RGD and KRSR for potentially enhanced effects on bone apposition and interfacial shear strength during early stages of bone regeneration. Two sets of experimental implants were placed in the maxillae of eight miniature pigs, known for their rapid wound healing kinetics: bone chamber implants creating two circular bone defects for histomorphometric analysis on one side and standard thread configuration implants for removal torque testing on the other side. Three different biofunctionalized modSLA surfaces using poly-L-lysine-graft-poly(ethylene glycol) (PLL-g-PEG) as a carrier minimizing nonspecific protein adsorption [(i) 20 pmol cm⁻² KRSR alone (KRSR); or in combination with RGD in two different concentrations; (ii) 0.05 pmol cm⁻² RGD (KRSR/RGD-1); (iii) 1.26 pmol cm⁻² RGD (KRSR/RGD-2)] were compared with (iv) control modSLA. Animals were sacrificed at 2 weeks. Removal torque values (701.48-780.28 N mm), bone-to-implant contact (BIC) (35.22%-41.49%), and new bone fill (28.58%-30.62%) demonstrated no significant differences among treatments. It may be concluded that biofunctionalizing modSLA surfaces with KRSR and RGD derivatives of PLL-g-PEG polymer does not increase BIC, bone fill, or interfacial shear strength.
Resumo:
Background In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. Methods Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically. Results Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials. Conclusion This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.