20 resultados para threshold position control

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Cochlear implants (CI) are standard treatment for prelingually deafened children and postlingually deafened adults. Computed tomography (CT) is the standard method for postoperative imaging of the electrode position. CT scans accurately reflect electrode depth and position, which is essential prior to use. However, routine CT examinations expose patients to radiation, which is especially problematic in children. We examined whether new CT protocols could reduce radiation doses while preserving diagnostic accuracy. METHODS To investigate whether electrode position can be assessed by low-dose CT protocols, a cadaveric lamb model was used because the inner ear morphology is similar to humans. The scans were performed at various volumetric CT dose-indexes CTDIvol)/kV combinations. For each constant CTDIvol the tube voltage was varied (i.e., 80, 100, 120 and 140kV). This procedure was repeated at different CTDIvol values (21mGy, 11mGy, 5.5mGy, 2.8mGy and 1.8mGy). To keep the CTDIvol constant at different tube voltages, the tube current values were adjusted. Independent evaluations of the images were performed by two experienced and blinded neuroradiologists. The criteria diagnostic usefulness, image quality and artifacts (scaled 1-4) were assessed in 14 cochlear-implanted cadaveric lamb heads with variable tube voltages. RESULTS Results showed that the standard CT dose could be substantially reduced without sacrificing diagnostic accuracy of electrode position. The assessment of the CI electrode position was feasible in almost all cases up to a CTDIvol of 2-3mGy. The number of artifacts did not increase for images within this dose range as compared to higher dosages. The extent of the artifacts caused by the implanted metal-containing CI electrode does not depend on the radiation dose and is not perceptibly influenced by changes in the tube voltage. Summarizing the evaluation of the CI electrode position is possible even at a very low radiation dose. CONCLUSIONS CT imaging of the temporal bone for postoperative electrode position control of the CI is possible with a very low and significantly radiation dose. The tube current-time product and voltage can be reduced by 50% without increasing artifacts. Low-dose postoperative CT scans are sufficient for localizing the CI electrode.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: In order to use a single implant with one treatment plan in fractionated high-dose-rate brachytherapy (HDR-B), applicator position shifts must be corrected prior to each fraction. The authors investigated the use of gold markers for X-ray-based setup and position control between the single fractions. PATIENTS AND METHODS: Caudad-cephalad movement of the applicators prior to each HDR-B fraction was determined on radiographs using two to three gold markers, which had been inserted into the prostate as intraprostatic reference, and one to two radiopaque-labeled reference applicators. 35 prostate cancer patients, treated by HDR-B as a monotherapy between 10/2003 and 06/2006 with four fractions of 9.5 Gy each, were analyzed. Toxicity was scored according to the CTCAE Score, version 3.0. Median follow-up was 3 years. RESULTS: The mean change of applicators positions compared to baseline varied substantially between HDR-B fractions, being 1.4 mm before fraction 1 (range, -4 to 2 mm), -13.1 mm before fraction 2 (range, -36 to 0 mm), -4.1 mm before fraction 3 (range, -21 to 9 mm), and -2.6 mm at fraction 4 (range, -16 to 9 mm). The original position of the applicators could be readjusted easily prior to each fraction in every patient. In 18 patients (51%), the applicators were at least once readjusted > 10 mm, however, acute or late grade > or = 2 genitourinary toxicity was not increased (p = 1.0) in these patients. CONCLUSION: Caudad position shifts up to 36 mm were observed. Gold markers represent a valuable tool to ensure setup accuracy and precise dose delivery in fractionated HDR-B monotherapy of prostate cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiac patients after an acute event and/or with chronic heart disease deserve special attention to restore their quality of life and to maintain or improve functional capacity. They require counselling to avoid recurrence through a combination of adherence to a medication plan and adoption of a healthy lifestyle. These secondary prevention targets are included in the overall goal of cardiac rehabilitation (CR). Cardiac rehabilitation can be viewed as the clinical application of preventive care by means of a professional multi-disciplinary integrated approach for comprehensive risk reduction and global long-term care of cardiac patients. The CR approach is delivered in tandem with a flexible follow-up strategy and easy access to a specialized team. To promote implementation of cardiac prevention and rehabilitation, the CR Section of the EACPR (European Association of Cardiovascular Prevention and Rehabilitation) has recently completed a Position Paper, entitled 'Secondary prevention through cardiac rehabilitation: A condition-oriented approach'. Components of multidisciplinary CR for seven clinical presentations have been addressed. Components include patient assessment, physical activity counselling, exercise training, diet/nutritional counselling, weight control management, lipid management, blood pressure monitoring, smoking cessation, and psychosocial management. Cardiac rehabilitation services are by definition multi-factorial and comprehensive, with physical activity counselling and exercise training as central components in all rehabilitation and preventive interventions. Many of the risk factor improvements occurring in CR can be mediated through exercise training programmes. This call-for-action paper presents the key components of a CR programme: physical activity counselling and exercise training. It summarizes current evidence-based best practice for the wide range of patient presentations of interest to the general cardiology community.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Socio economic inequalities in adult health behaviour are consistently observed. Despite a well-documented pattern, social determinants of variations in health behaviour have not been sufficiently clarified. This article therefore presents sociological pathways to explain the existing inequalities in health behaviour. At a micro level, control beliefs have been part of several behavioural theories. We suggest that these beliefs might bridge the gap between sociology and psychology by emphasising their roots in fundamental socio-economic environments. At a meso level, social networks and support have not been explicitly considered as behavioural determinants. This contribution states that these social factors influence health behaviour while being unequally distributed across society. At a macro level, characteristics of the neighbourhood environment influence health behaviour of its residents above and beyond their individual background. Providing further opportunity for policy makers, it is shown that peer and school context equalise inequalities in risky behaviour in adolescence. As a conclusion, factors such as control expectations, social networks, neighbourhood characteristics, and school context should be included as strategies to improve health behaviour in socially disadvantaged people.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Real-time quantitative polymerase chain reaction (qPCR) depends on precise temperature control of the sample during cycling. In the current study, we investigated how temperature variation in plate-based qPCR instruments influences qPCR results. Temperature variation was measured by amplicon melting analysis as a convenient means to assess well-to-well differences. Multiple technical replicates of several SYBR Green I-based qPCR assays allowed correlation of relative well temperature to quantification cycle. We found that inadequate template denaturation results in an inverse correlation and requires increasing the denaturation temperature, adding a DNA destabilizing agent, or pretreating with a restriction enzyme. In contrast, inadequate primer annealing results in a direct correlation and requires lowering the annealing temperature. Significant correlations were found in 18 of 25 assays. The critical nature of temperature-dependent effects was shown in a blinded study of 29 patients for the diagnosis of Prader-Willy and Angelman syndromes, where eight diagnoses were incorrect unless temperature-dependent effects were controlled. A method to detect temperature-dependent effects by pairwise comparisons of replicates in routine experiments is presented and applied. Systematic temperature errors in qPCR instruments can be recognized and their effects eliminated when high precision is required in quantitative genetic diagnostics and critical complementary DNA analyses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Ondansetron, a serotonin-3 receptor antagonist, reduces postoperative shivering. Drugs that reduce shivering usually impair central thermoregulatory control, and may thus be useful for preventing shivering during induction of therapeutic hypothermia. We determined, therefore, whether ondansetron reduces the major autonomic thermoregulatory response thresholds (triggering core temperatures) in humans. METHODS: Control (placebo) and ondansetron infusions at the target plasma concentration of 250 ng ml(-1) were studied in healthy volunteers on two different days. Each day, skin and core temperatures were increased to provoke sweating; then reduced to elicit peripheral vasoconstriction and shivering. We determined the core-temperature sweating, vasoconstriction and shivering thresholds after compensating for changes in mean-skin temperature. Data were analysed using t-tests and presented as means (sds); P<0.05 was taken as significant. RESULTS: Ondensetron plasma concentrations were 278 (57), 234 (55) and 243 (58) ng ml(-1) at the sweating, vasoconstriction and shivering thresholds, respectively; these corresponded to approximately 50 mg of ondansetron which is approximately 10 times the dose used for postoperative nausea and vomiting. Ondansetron did not change the sweating (control 37.4 (0.4) degrees C, ondansetron 37.6 (0.3) degrees C, P=0.16), vasoconstriction (37.0 (0.5) degrees C vs 37.1 (0.3) degrees C; P=0.70), or shivering threshold (36.3 (0.5) degrees C vs 36.3 (0.6) degrees C; P=0.76). No sedation was observed on either study day. CONCLUSIONS: /b>. Ondansetron appears to have little potential for facilitating induction of therapeutic hypothermia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Layer 2/3 (L2/3) pyramidal neurons are the most abundant cells of the neocortex. Despite their key position in the cortical microcircuit, synaptic integration in dendrites of L2/3 neurons is far less understood than in L5 pyramidal cell dendrites, mainly because of the difficulties in obtaining electrical recordings from thin dendrites. Here we directly measured passive and active properties of the apical dendrites of L2/3 neurons in rat brain slices using dual dendritic-somatic patch-clamp recordings and calcium imaging. Unlike L5 cells, L2/3 dendrites displayed little sag in response to long current pulses, which suggests a low density of I(h) in the dendrites and soma. This was also consistent with a slight increase in input resistance with distance from the soma. Brief current injections into the apical dendrite evoked relatively short (half-width 2-4 ms) dendritic spikes that were isolated from the soma for near-threshold currents at sites beyond the middle of the apical dendrite. Regenerative dendritic potentials and large concomitant calcium transients were also elicited by trains of somatic action potentials (APs) above a critical frequency (130 Hz), which was slightly higher than in L5 neurons. Initiation of dendritic spikes was facilitated by backpropagating somatic APs and could cause an additional AP at the soma. As in L5 neurons, we found that distal dendritic calcium transients are sensitive to a long-lasting block by GABAergic inhibition. We conclude that L2/3 pyramidal neurons can generate dendritic spikes, sharing with L5 pyramidal neurons fundamental properties of dendritic excitability and control by inhibition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Mild therapeutic hypothermia has been shown to improve outcome for patients after cardiac arrest and may be beneficial for ischaemic stroke and myocardial ischaemia patients. However, in the awake patient, even a small decrease of core temperature provokes vigorous autonomic reactions-vasoconstriction and shivering-which both inhibit efficient core cooling. Meperidine and skin warming each linearly lower vasoconstriction and shivering thresholds. We tested whether a combination of skin warming and a medium dose of meperidine additively would reduce the shivering threshold to below 34 degrees C without producing significant sedation or respiratory depression. METHODS: Eight healthy volunteers participated on four study days: (1) control, (2) skin warming (with forced air and warming mattress), (3) meperidine (target plasma level: 0.9 mug/ml), and (4) skin warming plus meperidine (target plasma level: 0.9 mug/ml). Volunteers were cooled with 4 degrees C cold Ringer lactate infused over a central venous catheter (rate asymptotically equal to 2.4 degrees C/hour core temperature drop). Shivering threshold was identified by an increase of oxygen consumption (+20% of baseline). Sedation was assessed with the Observer's Assessment of Alertness/Sedation scale. RESULTS: Control shivering threshold was 35.5 degrees C +/- 0.2 degrees C. Skin warming reduced the shivering threshold to 34.9 degrees C +/- 0.5 degrees C (p = 0.01). Meperidine reduced the shivering threshold to 34.2 degrees C +/- 0.3 degrees C (p < 0.01). The combination of meperidine and skin warming reduced the shivering threshold to 33.8 degrees C +/- 0.2 degrees C (p < 0.01). There were no synergistic or antagonistic effects of meperidine and skin warming (p = 0.59). Only very mild sedation occurred on meperidine days. CONCLUSION: A combination of meperidine and skin surface warming reduced the shivering threshold to 33.8 degrees C +/- 0.2 degrees C via an additive interaction and produced only very mild sedation and no respiratory toxicity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: We compared motor and movement thresholds to transcranial magnetic stimulation (TMS) in healthy subjects and investigated the effect of different coil positions on thresholds and MEP (motor-evoked potential) amplitudes. METHODS: The abductor pollicis brevis (APB) 'hot spot' and a standard scalp position were stimulated. APB resting motor threshold (APB MEP-MT) defined by the '5/10' electrophysiological method was compared with movement threshold (MOV-MT), defined by visualization of movements. Additionally, APB MEP-MTs were evaluated with the '3/6 method,' and MEPs were recorded at a stimulation intensity of 120% APB MEP-MT at each position. RESULTS: APB MEP-MTs were significantly lower by stimulation of the 'hot spot' than of the standard position, and significantly lower than MOV-MTs (n=15). There were no significant differences between the '3/6' and the '5/10' methods, or between APB MEP amplitudes by stimulating each position at 120% APB MEP-MT. CONCLUSIONS: Coil position and electrophysiological monitoring influenced motor threshold determinations. Performing 6 instead of 10 trials did not produce different threshold measurements. Adjustment of intensity according to APB MEP-MT at the stimulated position did not influence APB MEP amplitudes. SIGNIFICANCE: Standardization of stimulation positions, nomenclature and criteria for threshold measurements should be considered in design and comparison of TMS protocols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Interaction refers to the situation in which the effect of 1 exposure on an outcome differs across strata of another exposure. We did a survey of epidemiologic studies published in leading journals to examine how interaction is assessed and reported. METHODS: We selected 150 case-control and 75 cohort studies published between May 2001 and May 2007 in leading general medicine, epidemiology, and clinical specialist journals. Two reviewers independently extracted data on study characteristics. RESULTS: Of the 225 studies, 138 (61%) addressed interaction. Among these, 25 (18%) presented no data or only a P value or a statement of statistical significance; 40 (29%) presented stratum-specific effect estimates but no meaningful comparison of these estimates; and 58 (42%) presented stratum-specific estimates and appropriate tests for interaction. Fifteen articles (11%) presented the individual effects of both exposures and also their joint effect or a product term, providing sufficient information to interpret interaction on an additive and multiplicative scale. Reporting was poorest in articles published in clinical specialist articles and most adequate in articles published in general medicine journals, with epidemiology journals in an intermediate position. CONCLUSIONS: A majority of articles reporting cohort and case-control studies address possible interactions between exposures. However, in about half of these, the information provided was unsatisfactory, and only 1 in 10 studies reported data that allowed readers to interpret interaction effects on an additive and multiplicative scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Macrophage migration inhibitory factor (MIF) plays an important regulatory role in sepsis. In the promoter region a C/G single nucleotide polymorphism (SNP) at position -173 (rs755622) and a CATT5-8 microsatellite at position -794 are related to modified promoter activity. The purpose of the study was to analyze their association with the incidence and outcome of severe sepsis. METHODS: Genotype distributions and allele frequencies in 169 patients with severe sepsis, 94 healthy blood donors and 183 postoperative patients without signs of infection or inflammation were analyzed by real time PCR and Sequence analysis. All included individuals were Caucasians. RESULTS: Genotype distribution and allele frequencies of severe sepsis patients were comparable to both control groups. However, the genotype and allele frequencies of both polymorphisms were associated significantly with the outcome of severe sepsis. The highest risk of dying from severe sepsis was detectable in patients carrying a haplotype with the alleles -173 C and CATT7 (p = 0.0005, fisher exact test, RR = 1,806, CI: 1.337 to 2.439). CONCLUSION: The haplotype with the combination of the -173 C allele and the -794 CATT7 allele may not serve as a marker for susceptibility to sepsis, but may help identify septic patients at risk of dying.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vibrations, Posture, and the Stabilization of Gaze: An Experimental Study on Impedance Control R. KREDEL, A. GRIMM & E.-J. HOSSNER University of Bern, Switzerland Introduction Franklin and Wolpert (2011) identify impedance control, i.e., the competence to resist changes in position, velocity or acceleration caused by environmental disturbances, as one of five computational mechanisms which allow for skilled and fluent sen-sorimotor behavior. Accordingly, impedance control is of particular interest in situa-tions in which the motor task exhibits unpredictable components as it is the case in downhill biking or downhill skiing. In an experimental study, the question is asked whether impedance control, beyond its benefits for motor control, also helps to stabi-lize gaze what, in turn, may be essential for maintaining other control mechanisms (e.g., the internal modeling of future states) in an optimal range. Method In a 3x2x4 within-subject ANOVA design, 72 participants conducted three tests on visual acuity and contrast (Landolt / Grating and Vernier) in two different postures (standing vs. squat) on a platform vibrating at four different frequencies (ZEPTOR; 0 Hz, 4 Hz, 8 Hz, 12 Hz; no random noise; constant amplitude) in a counterbalanced or-der with 1-minute breaks in-between. In addition, perceived exertion (Borg) was rated by participants after each condition. Results For Landolt and Grating, significant main effects for posture and frequency are re-vealed, representing lower acuity/contrast thresholds for standing and for higher fre-quencies in general, as well as a significant interaction (p < .05), standing for in-creasing posture differences with increasing frequencies. Overall, performance could be maintained at the 0 Hz/standing level up to a frequency of 8 Hz, if bending of the knees was allowed. The fact that this result is not only due to exertion is proved by the Borg ratings showing significant main effects only, i.e., higher exertion scores for standing and for higher frequencies, but no significant interaction (p > .40). The same pattern, although not significant, is revealed for the Vernier test. Discussion Apparently, postures improving impedance control not only turn out to help to resist disturbances but also assist in stabilizing gaze in spite of these perturbations. Con-sequently, studying the interaction of these control mechanisms in complex unpre-dictable environments seems to be a fruitful field of research for the future. References Franklin, D. W., & Wolpert, D. M. (2011). Computational mechanisms of sensorimotor control. Neuron, 72, 425-442.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of pressure waves to confirm the correct position of the epidural needle has been described in several domestic species and proposed as a valid alternative to standard methods, namely, control radiographic exam and fluoroscopy. The object of this retrospective clinical study was to evaluate the sensitivity of the epidural pressure waves as a test to verify the correct needle placement in the epidural space in dogs, in order to determine whether this technique could be useful not only in the clinical setting but also when certain knowledge of needle's tip position is required, for instance when performing clinical research focusing on epidural anaesthesia. Of the 54 client-owned dogs undergoing elective surgeries and enrolled in this retrospective study, only 45% showed epidural pressure waves before and after epidural injection. Twenty-six percent of the animals showed epidural pressure waves only after the injection, whereas 29% of the dogs showed epidural pressure waves neither before nor after injection and were defined as false negatives. Our results show that the epidural pressure wave technique to verify epidural needle position lacks sensitivity, resulting in many false negatives. As a consequence, the applicability of this technique is limited to situations in which precise, exact knowledge of the needle's tip position is not mandatory.