33 resultados para the scanning reference electrode technique

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the clinical outcome of horizontal ridge augmentation using autogenous block grafts covered with an organic bovine bone mineral (ABBM) and a bioabsorbable collagen membrane. MATERIAL AND METHODS: In 42 patients with severe horizontal bone atrophy, a staged approach was chosen for implant placement following horizontal ridge augmentation. A block graft was harvested from the symphysis or retromolar area, and secured to the recipient site with fixation screws. The width of the ridge was measured before and after horizontal ridge augmentation. The block graft was subsequently covered with ABBM and a collagen membrane. Following a tension-free primary wound closure and a mean healing period of 5.8 months, the sites were re-entered, and the crest width was re-assessed prior to implant placement. RESULTS: Fifty-eight sites were augmented, including 41 sites located in the anterior maxilla. The mean initial crest width measured 3.06 mm. At re-entry, the mean width of the ridge was 7.66 mm, with a calculated mean gain of horizontal bone thickness of 4.6 mm (range 2-7 mm). Only minor surface resorption of 0.36 mm was observed from augmentation to re-entry. CONCLUSIONS: The presented technique of ridge augmentation using autogenous block grafts with ABBM filler and collagen membrane coverage demonstrated successful horizontal ridge augmentation with high predictability. The surgical method has been further simplified by using a resorbable membrane. The hydrophilic membrane was easy to apply, and did not cause wound infection in the rare instance of membrane exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although loosening of cemented glenoid components is one of the major complications of total shoulder arthroplasty, there is little information about factors affecting initial fixation of these components in the scapular neck. This study was performed to assess the characteristics of structural fixation of pegged glenoid components, if inserted with two different recommended cementing techniques. Six fresh-frozen shoulder specimens and two types of glenoid components were used. The glenoids were prepared according to the instructions and with the instrumentation of the manufacturer. In 3 specimens, the bone cement was inserted into the peg receiving holes (n = 12) and applied to the back surface of the glenoid component with a syringe. In the other 3 specimens, the cement was inserted into the holes (n = 15) by use of pure finger pressure: no cement was applied on the backside of the component. Micro-computed tomography scans with a resolution of 36 microm showed an intact cement mantle around all 12 pegs (100%) when a syringe was used. An incomplete cement plug was found in 7 of 15 pegs (47%) when the finger-pressure technique was used. Cement penetration into the cancellous bone was deeper in osteopenic bone. Application of bone cement on the backside of the glenoid prosthesis improved seating by filling out small spaces between bone and polyethylene resulting from irregularities after reaming or local cement extrusion from a drill hole. The fixation of a pegged glenoid component is better if the holes are filled with cement under pressure by use of a syringe and if cement is applied to the back of the glenoid component than if cement is inserted with pure finger pressure and no cement is applied to the back surface of the component.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Musicians often suffer injuries related to their music playing. Therefore, some use Alexander Technique (AT), a mental-physical method that facilitates to release unnecessary muscle tension and to re-educate non-beneficial movement patterns through enhanced kinaesthetic awareness. According to a recent review AT may be effective for chronic back pain [1]. This review aimed to evaluate the evidence for the effectiveness of AT lessons on music performance and musicians’ health and well-being. Methods The following electronic databases were searched up to July 2012 for relevant literature: PUBMED, Google Scholar, CINAHL and EMBASE. The search criteria were "Alexander technique" AND "music*" [all fields]. References were searched, and experts and societies of AT or musicians' medicine contacted for further publications. Results 100 studies were identified. 24 studies were included for further analysis, 5 of which were randomised controlled trials (RCTs), 5 controlled but not randomised (CTs), 5 without control group, 2 mixed methods (RCT and case studies), and 7 surveys. 13 to 72 musicians participated per RCT. In 5 RCTs AT groups received between 12 and 20 one-to-one lessons. In 4 RCTs control groups received no interventions. Primary outcomes were performance anxiety, music performance, "use" as well as respiratory function and pain. Performance anxiety decreased by AT in 3 of 4 RCTs and in 3 of 3 CTs. Music performance was improved by AT in 1 RCT, yet in 2 RCTs comparing neurofeedback (NF) to AT, only NF showed improvements. Discussion and Conclusion To investigate the effectiveness of AT in musicians a variety of study designs and outcome measures have been used. Evidence from RCTs suggests that AT may improve performance anxiety in musicians. Effects on music performance, body use and respiratory function yet remain inconsistent. Future trials with scientifically sound study designs are warranted to further and more reliably explore the potential of AT as a relatively low cost and low risk method in the interest of musicians. References [1] Woodman JP, Moore NR. Evidence for the effectiveness of Alexander Technique lessons in medical and health-related conditions: a systematic review. Int J Clin Pract 2012;66(1):98-112.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose Musicians often suffer injuries related to their music playing. Therefore, some use the Alexander Technique (AT), a psycho-physical method that helps to release unnecessary muscle tension and re-educates non-beneficial movement patterns through enhanced kinaesthetic awareness. According to a recent review AT may be effective for chronic back pain. This review aimed to evaluate the evidence for the effectiveness of AT lessons on music performance and musicians’ health and well-being. Methods The following electronic databases were searched up to July 2012 for relevant literature: PUBMED, Google Scholar, CINAHL and EMBASE. The search criteria were "Alexander technique" AND "music*" [all fields]. References were searched, and experts and societies of AT or musicians' medicine contacted for further publications. Results 100 studies were identified. 35 studies were included for further analysis, 5 of which were randomised controlled trials (RCTs), 5 controlled but not randomised, 5 not controlled, 5 qualitative case studies, 2 mixed-models (RCT and case studies), 7 surveys, 4 qualitative case reports and 2 unpublished pilot studies. 13 to 72 musicians participated per RCT. In 5 RCTs AT groups received between 12 and 20 one-to-one lessons. In 4 RCTs control groups received no interventions. Primary outcomes were performance anxiety, performance, "use" as well as respiratory function and pain. Performance anxiety decreased by AT in 3 of 4 RCTs. Music performance was improved by AT in 1 RCT, yet in 2 RCTs comparing neurofeedback (NF) to AT, only NF showed improvements. Conclusions To investigate the effectiveness of AT in musicians a variety of study designs and outcome measures have been used. Evidence from RCTs suggests that AT may improve performance anxiety in musicians. Effects on music performance, body use and respiratory function yet remain inconsistent. Future trials with well-established study designs are warranted to further and more reliably explore the potential of AT as a relatively low cost and low risk method in the interest of musicians.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Both acetabular undercoverage (hip dysplasia) and overcoverage (pincer-type femoroacetabular impingement) can result in hip osteoarthritis. In contrast to undercoverage, there is a lack of information on radiographic reference values for excessive acetabular coverage. Questions/purposes (1) How do common radiographic hip parameters differ in hips with a deficient or an excessive acetabulum in relation to a control group; and (2) what are the reference values determined from these data for acetabular under- and overcoverage? Methods We retrospectively compared 11 radiographic parameters describing the radiographic acetabular anatomy among hip dysplasia (26 hips undergoing periacetabular osteotomy), control hips (21 hips, requiring no rim trimming during surgical hip dislocation), hips with overcoverage (14 hips, requiring rim trimming during surgical hip dislocation), and hips with severe overcoverage (25 hips, defined as having acetabular protrusio). The hips were selected from a patient cohort of a total of 593 hips. Radiographic parameters were assessed with computerized methods on anteroposterior pelvic radiographs and corrected for neutral pelvic orientation with the help of a true lateral radiograph. Results All parameters except the crossover sign differed among the four study groups. From dysplasia through control and overcoverage, the lateral center-edge angle, acetabular arc, and anteroposterior/craniocaudal coverage increased. In contrast, the medial center-edge angle, extrusion/acetabular index, Sharp angle, and prevalence of the posterior wall sign decreased. The following reference values were found: lateral center-edge angle 23° to 33°, medial center-edge angle 35° to 44°, acetabular arc 61° to 65°, extrusion index 17% to 27%, acetabular index 3° to 13°, Sharp angle 38° to 42°, negative crossover sign, positive posterior wall sign, anterior femoral head coverage 15% to 26%, posterior femoral head coverage 36% to 47%, and craniocaudal coverage 70% to 83%. Conclusions These acetabular reference values define excessive and deficient coverage. They may be used for radiographic evaluation of symptomatic hips, may offer possible predictors for surgical outcomes, and serve to guide clinical decision-making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The implementation of new surgical techniques offers chances but carries risks. Usually, several years pass before a critical appraisal and a balanced opinion of a new treatment method are available and rely on the evidence from the literature and expert's opinion. The frozen elephant trunk (FET) technique has been increasingly used to treat complex pathologies of the aortic arch and the descending aorta, but there still is an ongoing discussion within the surgical community about the optimal indications. This paper represents a common effort of the Vascular Domain of EACTS together with several surgeons with particular expertise in aortic surgery, and summarizes the current knowledge and the state of the art about the FET technique. The majority of the information about the FET technique has been extracted from 97 focused publications already available in the PubMed database (cohort studies, case reports, reviews, small series, meta-analyses and best evidence topics) published in English.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Correction of all kind of deformities at the distal part of the femur (supracondylar). INDICATIONS Flexion, extension osteotomies, and varus or valgus, and external or internal rotation osteotomies, and shortening osteotomies of the distal femur or combined surgical procedures (e.g., extension and de-rotation osteotomy). CONTRAINDICATIONS Osteotomy through unknown bony process. SURGICAL TECHNIQUE LCP system provides angular stable fixation. POSTOPERATIVE MANAGEMENT Without concomitant surgical procedures of soft tissue (e.g., patellar tendon shortening), early functional rehabilitation is possible with immediate weight bearing (35 kg for small fragment plates and 70 kg for large fragment plates). RESULTS The surgical procedure is safe and is associated with few complications. Overall complication rate in this series of patients was 3%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We calibrated the ⁸¹Kr-Kr dating system for ordinary chondrites of different sizes using independent shielding-corrected ³⁶Cl-³⁶Ar ages. Krypton concentrations and isotopic compositions were measured in bulk samples from 14 ordinary chondrites of high petrologic type and the cosmogenic Kr component was obtained by subtracting trapped Kr from phase Q. The thus-determined average cosmogenic ⁷⁸Kr/⁸³Kr, ⁸⁰Kr/⁸³Kr, ⁸²Kr/⁸³Kr, and ⁸4Kr/⁸³Kr ratiC(Lavielle and Marti 1988; Wieler 2002). The cosmogenic ⁷⁸Kr/⁸³Kr ratio is correlated with the cosmogenic 22Ne/21Ne ratio, confirming that ⁷⁸Kr/⁸³Kr is a reliable shielding indicator. Previously, ⁸¹Kr-Kr ages have been determined by assuming the cosmogenic production rate of ⁸¹Kr, P(⁸¹Kr)c, to be 0.95 times the average of the cosmogenic production rates of ⁸⁰Kr and ⁸²Kr; the factor Y = 0.95 therefore accounts for the unequal production of the various Kr isotopes (Marti 1967a). However, Y should be regarded as an empirical adjustment. For samples whose ⁸⁰Kr and ⁸²Kr concentrations may be affected by neutron-capture reactions, the shielding-dependent cosmogenic (⁷⁸Kr/⁸³Kr)c ratio has been used instead to calculate P(⁸¹Kr)/P(⁸³Kr), as for some lunar samples, this ratio has been shown to linearly increase with (⁷⁸Kr/⁸³Kr)c (Marti and Lugmair 1971). However, the ⁸¹Kr-Kr ages of our samples calculated with these methods are on average ~30% higher than their ³⁶Cl-³⁶Ar ages, indicating that most if not all the ⁸¹Kr-Kr ages determined so far are significantly too high. We therefore re-evaluated both methods to determine P(⁸¹Kr)c/P(⁸³Kr)c. Our new Y value of 0.70 ± 0.04 is more than 25% lower than the value of 0.95 used so far. Furthermore, together with literature data, our data indicate that for chondrites, P(⁸¹Kr)c/P(⁸³Kr)c is rather constant at 0.43 ± 0.02, at least for the shielding range covered by our samples ([⁷⁸Kr/⁸³Kr]c = 0.119–0.185; [22Ne/21Ne]c = 1.083–1.144), in contrast to the observations on lunar samples. As expected considering the method used, ⁸¹Kr-Kr ages calculated either directly with this new P(⁸¹Kr)c/P(⁸³Kr)c value or with our new Y value both agree with the corresponding ³⁶Cl-³⁶Ar ages. However, the average deviation of 2% indicates the accuracy of both new ⁸¹Kr-Kr dating methods and the precision of the new dating systems of ~10% is demonstrated by the low scatter in the data. Consequently, this study indicates that the ⁸¹Kr-Kr ages published so far are up to 30% too high.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the United States, rumenocentesis has been recommended especially for early diagnosis of subacute rumen acidosis (SARA). The objective of the current study was to evaluate health risks due to the technique ofrumenocentesis and to measure pH in ruminal juice using a commercial indicator paper (Pehanon) and a pH electrode (reference method). After 11 dairy cows underwent rumenocentesis, the clinical status of those animals was evaluated daily, and cows were slaughtered as well as pathologically--anatomically examined on day 7. During the observation period, the following pathological clinical signs were evident: forced inspiration (3 cows), transient episode of hyperthermia (2 cows), increased tension of the abdominal wall (8 cows) and positive foreign body tests (3 cows). One cow had to be culled on day 7 because of severe generalised septic peritonitis spreading from the site of rumenocentesis. At slaughter, hematoma formation in the area of the puncture site was found in 9 out of 10 cows. It was concluded that the severe complications encountered with this technique do not legitimate rumenocentesis as a routine procedure for collection of rumen juice samples in cows under Swiss conditions. The correlation between the pH reference method and the commercial indicator paper was the high (r = 0.926).