56 resultados para the choice of material
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
In surgical animal studies anesthesia is used regularly. Several reports in the literature demonstrate respiratory and cardiovascular side effects of anesthesiologic agents. The aim of this study was to compare two frequently used anesthesia cocktails (ketamine/xylazine [KX] versus medetomidine/climazolam/fentanyl [MCF]) in skin flap mouse models. Systemic blood values, local metabolic parameters, and surgical outcome should be analyzed in critical ischemic skin flap models. Systemic hypoxia was found in the animals undergoing KX anesthesia compared with normoxia in the MCF group (sO(2): 89.2% +/- 2.4% versus 98.5% +/- 1.2%, P < 0.01). Analysis of tissue metabolism revealed impaired anaerobic oxygen metabolism and increased cellular damage in critical ischemic flap tissue under KX anesthesia (lactate/pyruvate ratio: KX 349.86 +/- 282.38 versus MCF 64.53 +/- 18.63; P < 0.01 and glycerol: KX 333.50 +/- 83.91 micromol/L versus MCF 195.83 +/- 29.49 micromol/L; P < 0.01). After 6 d, different rates of flap tissue necrosis could be detected (MCF 57% +/- 6% versus KX 68% +/- 6%, P < 0.01). In summary we want to point out that the type of anesthesia, the animal model and the goal of the study have to be well correlated. Comparing the effects of KX and MCF anesthesia in mice on surgical outcome was a novel aspect of our study.
Resumo:
Biofilms on oral piercings may serve as a bacterial reservoir and lead to systemic bacteremia or local transmission of pathogenic microbiota. The use of piercing materials which are less susceptible to biofilm accumulation could contribute to prevention of problems. The present study investigated whether there are microbiological differences in bacterial samples collected from tongue piercings made of different materials.
Resumo:
We report a detailed physical analysis on a family of isolated, antiferro-magnetically (AF) coupled, chromium(III) finite chains, of general formula (Cr(RCO(2))(2)F)(n) where the chain length n = 6 or 7. Additionally, the chains are capped with a selection of possible terminating ligands, including hfac (= 1,1,1,5,5,5-hexafluoropentane-2,4-dionate(1-)), acac (= pentane-2,4-dionate(1-)) or (F)(3). Measurements by inelastic neutron scattering (INS), magnetometery and electron paramagnetic resonance (EPR) spectroscopy have been used to study how the electronic properties are affected by n and capping ligand type. These comparisons allowed the subtle electronic effects the choice of capping ligand makes for odd member spin 3/2 ground state and even membered spin 0 ground state chains to be investigated. For this investigation full characterisation of physical properties have been performed with spin Hamiltonian parameterisation, including the determination of Heisenberg exchange coupling constants and single ion axial and rhombic anisotropy. We reveal how the quantum spin energy levels of odd or even membered chains can be modified by the type of capping ligand terminating the chain. Choice of capping ligands enables Cr-Cr exchange coupling to be adjusted by 0, 4 or 24%, relative to Cr-Cr exchange coupling within the body of the chain, by the substitution of hfac, acac or (F)(3) capping ligands to the ends of the chain, respectively. The manipulation of quantum spin levels via ligands which play no role in super-exchange, is of general interest to the practise of spin Hamilton modelling, where such second order effects are generally not considered of relevance to magnetic properties.
Resumo:
PURPOSE: To determine how the ADC value of parotid glands is influenced by the choice of b-values. MATERIALS AND METHODS: In eight healthy volunteers, diffusion-weighted echo-planar imaging (DW-EPI) was performed on a 1.5 T system, with b-values (in seconds/mm2) of 0, 50, 100, 150, 200, 250, 300, 500, 750, and 1000. ADC values were calculated by two alternative methods (exponential vs. logarithmic fit) from five different sets of b-values: (A) all b-values; (B) b=0, 50, and 100; (C) b=0 and 750; (D) b=0, 500, and 1000; and (E) b=500, 750, and 1000. RESULTS: The mean ADC values for the different settings were (in 10(-3) mm2/second, exponential fit): (A) 0.732+/-0.019, (B) 2.074+/-0.084, (C) 0.947+/-0.020, (D) 0.890+/-0.023, and (E) 0.581+/-0.021. ADC values were significantly (P <0.001) different for all pairwise comparisons of settings (A-E) of b-values, except for A vs. D (P=0.172) and C vs. D (P=0.380). The ADC(B) was significantly higher than ADC(C) or ADC(D), which was significantly higher than ADC(E). ADC values from exponential vs. logarithmic fit (P=0.542), as well as left vs. right parotid gland (P=0.962), were indistinguishable. CONCLUSION: The ADC values calculated from low b-value settings were significantly higher than those calculated from high b-value settings. These results suggest that not only true diffusion but also perfusion and saliva flow may contribute to the ADC.
Resumo:
The paper analyzes how to comply with an emission constraint, which restricts the use of an established energy technique, given the two options to save energy and to invest in two alternative energy techniques. These techniques differ in their deterioration rates and the investment lags of the corresponding capital stocks. Thus, the paper takes a medium-term perspective on climate change mitigation, where the time horizon is too short for technological change to occur, but long enough for capital stocks to accumulate and deteriorate. It is shown that, in general, only one of the two alternative techniques prevails in the stationary state, although, both techniques might be utilized during the transition phase. Hence, while in a static economy only one technique is efficient, this is not necessarily true in a dynamic economy.
Resumo:
PURPOSE The purpose of this study was to investigate whether there are microbiological differences in bacterial samples collected from labial piercings made of different materials. METHODS Sterile piercings of 4 materials were randomly allocated to 80 pierced subjects. After 2 weeks, microbiologic samples were collected and processed by checkerboard DNA-DNA hybridization methods. Wilcoxon signed ranks and Mann-Whitney tests were used for statistical analysis (adjustment for multiple comparisons). RESULTS There were no statistically significant differences between material groups in relation to baseline data. In samples from stainless steel piercings, the total microbial load was significantly higher than the other materials (P<.05). Ten (mainly periopathogenic) species were found at significantly higher levels (P<.001) on steel than on polypropylene and/or polytetrafluoroethylene piercings. CONCLUSIONS Labial piercings made of stainless steel could promote the development of a pathogenic biofilm.
Resumo:
Endodontic treatment, involves removal of the dental pulp and its replacement by a root canal filling. Restoration of root filled teeth can be challenging due to structural differences between vital and non-vital root filled teeth. Direct restoration involves placement of a restorative material e.g. amalgam or composite directly into the tooth. Indirect restorations consist of cast metal or ceramic (porcelain) crowns. The choice of restoration depends on the amount of remaining tooth which may influence long term survival and cost. The comparative in service clinical performance of crowns or conventional fillings used to restore root filled teeth is unclear.
Resumo:
AIM To systematically assess the efficacy of patient-administered mechanical and/or chemical plaque control protocols in the management of peri-implant mucositis (PM). MATERIAL AND METHODS Randomized (RCTs) and Controlled Clinical Trials (CCTs) were identified through an electronic search of three databases complemented by manual search. Identification, screening, eligibility and inclusion of studies was performed independently by two reviewers. Studies without professional intervention or with only mechanical debridement professionally administered were included. Quality assessment was performed by means of the Cochrane Collaboration's tool for assessing risk of bias. RESULTS Eleven RCTs with a follow-up from 3 to 24 months were included. Definition of PM was lacking or heterogeneously reported. Complete resolution of PM was not achieved in any study. One study reported 38% of patients with complete resolution of PM. Surrogate end-point outcomes of PM therapy were often reported. The choice of control interventions showed great variability. The efficacy of powered toothbrushes, a triclosan-containing toothpaste and adjunctive antiseptics remains to be established. High quality of methods and reporting was found in four studies. CONCLUSIONS Professionally- and patient-administered mechanical plaque control alone should be considered the standard of care in the management of PM. Therapy of PM is a prerequisite for the prevention of peri-implantitis.
Resumo:
BACKGROUND Endodontic treatment involves removal of the dental pulp and its replacement by a root canal filling. Restoration of root filled teeth can be challenging due to structural differences between vital and non-vital root-filled teeth. Direct restoration involves placement of a restorative material e.g. amalgam or composite, directly into the tooth. Indirect restorations consist of cast metal or ceramic (porcelain) crowns. The choice of restoration depends on the amount of remaining tooth, and may influence durability and cost. The decision to use a post and core in addition to the crown is clinician driven. The comparative clinical performance of crowns or conventional fillings used to restore root-filled teeth is unknown. This review updates the original, which was published in 2012. OBJECTIVES To assess the effects of restoration of endodontically treated teeth (with or without post and core) by crowns versus conventional filling materials. SEARCH METHODS We searched the following databases: the Cochrane Oral Health Group's Trials Register, CENTRAL, MEDLINE via OVID, EMBASE via OVID, CINAHL via EBSCO, LILACS via BIREME. We also searched the reference lists of articles and ongoing trials registries.There were no restrictions regarding language or date of publication. The search is up-to-date as of 26 March 2015. SELECTION CRITERIA Randomised controlled trials (RCTs) or quasi-randomised controlled trials in participants with permanent teeth that have undergone endodontic treatment. Single full coverage crowns compared with any type of filling materials for direct restoration or indirect partial restorations (e.g. inlays and onlays). Comparisons considered the type of post and core used (cast or prefabricated post), if any. DATA COLLECTION AND ANALYSIS Two review authors independently extracted data from the included trial and assessed its risk of bias. We carried out data analysis using the 'treatment as allocated' patient population, expressing estimates of intervention effect for dichotomous data as risk ratios, with 95% confidence intervals (CI). MAIN RESULTS We included one trial, which was judged to be at high risk of performance, detection and attrition bias. The 117 participants with a root-filled, premolar tooth restored with a carbon fibre post, were randomised to either a full coverage metal-ceramic crown or direct adhesive composite restoration. None experienced a catastrophic failure (i.e. when the restoration cannot be repaired), although only 104 teeth were included in the final, three-year assessment. There was no clear difference between the crown and composite group and the composite only group for non-catastrophic failures of the restoration (1/54 versus 3/53; RR 0.33; 95% CI 0.04 to 3.05) or failures of the post (2/54 versus 1/53; RR 1.96; 95% CI 0.18 to 21.01) at three years. The quality of the evidence for these outcomes is very low. There was no evidence available for any of our secondary outcomes: patient satisfaction and quality of life, incidence or recurrence of caries, periodontal health status, and costs. AUTHORS' CONCLUSIONS There is insufficient evidence to assess the effects of crowns compared to conventional fillings for the restoration of root-filled teeth. Until more evidence becomes available, clinicians should continue to base decisions about how to restore root-filled teeth on their own clinical experience, whilst taking into consideration the individual circumstances and preferences of their patients.
Resumo:
This paper will review the literature in order to define lesion characteristics that determine decision for surgical or endovascular therapy in patients with chronic critical limb ischemia (CLI). The typical pattern of disease is multilevel, infrainguinal disease. The great majority of patients with CLI can be treated by endovascular means, and the pathoanatomical pattern of disease dictates the choice of treatment modality. Long iliac artery occlusions, in particular, if associated with common femoral artery pathology and long superficial femoral artery occlusions crossing the knee joint so far remain a domain of surgery. However, there is an ongoing shift from surgery to endovascular treatment.
Resumo:
For the development of meniscal substitutes and related finite element models it is necessary to know the mechanical properties of the meniscus and its attachments. Measurement errors can falsify the determination of material properties. Therefore the impact of metrological and geometrical measurement errors on the determination of the linear modulus of human meniscal attachments was investigated. After total differentiation the error of the force (+0.10%), attachment deformation (−0.16%), and fibre length (+0.11%) measurements almost annulled each other. The error of the cross-sectional area determination ranged from 0.00%, gathered from histological slides, up to 14.22%, obtained from digital calliper measurements. Hence, total measurement error ranged from +0.05% to −14.17%, predominantly affected by the cross-sectional area determination error. Further investigations revealed that the entire cross-section was significantly larger compared to the load-carrying collagen fibre area. This overestimation of the cross-section area led to an underestimation of the linear modulus of up to −36.7%. Additionally, the cross-sections of the collagen-fibre area of the attachments significantly varied up to +90% along their longitudinal axis. The resultant ratio between the collagen fibre area and the histologically determined cross-sectional area ranged between 0.61 for the posterolateral and 0.69 for the posteromedial ligament. The linear modulus of human meniscal attachments can be significantly underestimated due to the use of different methods and locations of cross-sectional area determination. Hence, it is suggested to assess the load carrying collagen fibre area histologically, or, alternatively, to use the correction factors proposed in this study.
Resumo:
BACKGROUND Current guidelines give recommendations for preferred combination antiretroviral therapy (cART). We investigated factors influencing the choice of initial cART in clinical practice and its outcome. METHODS We analyzed treatment-naive adults with human immunodeficiency virus (HIV) infection participating in the Swiss HIV Cohort Study and starting cART from January 1, 2005, through December 31, 2009. The primary end point was the choice of the initial antiretroviral regimen. Secondary end points were virologic suppression, the increase in CD4 cell counts from baseline, and treatment modification within 12 months after starting treatment. RESULTS A total of 1957 patients were analyzed. Tenofovir-emtricitabine (TDF-FTC)-efavirenz was the most frequently prescribed cART (29.9%), followed by TDF-FTC-lopinavir/r (16.9%), TDF-FTC-atazanavir/r (12.9%), zidovudine-lamivudine (ZDV-3TC)-lopinavir/r (12.8%), and abacavir/lamivudine (ABC-3TC)-efavirenz (5.7%). Differences in prescription were noted among different Swiss HIV Cohort Study sites (P < .001). In multivariate analysis, compared with TDF-FTC-efavirenz, starting TDF-FTC-lopinavir/r was associated with prior AIDS (relative risk ratio, 2.78; 95% CI, 1.78-4.35), HIV-RNA greater than 100 000 copies/mL (1.53; 1.07-2.18), and CD4 greater than 350 cells/μL (1.67; 1.04-2.70); TDF-FTC-atazanavir/r with a depressive disorder (1.77; 1.04-3.01), HIV-RNA greater than 100 000 copies/mL (1.54; 1.05-2.25), and an opiate substitution program (2.76; 1.09-7.00); and ZDV-3TC-lopinavir/r with female sex (3.89; 2.39-6.31) and CD4 cell counts greater than 350 cells/μL (4.50; 2.58-7.86). At 12 months, 1715 patients (87.6%) achieved viral load less than 50 copies/mL and CD4 cell counts increased by a median (interquartile range) of 173 (89-269) cells/μL. Virologic suppression was more likely with TDF-FTC-efavirenz, and CD4 increase was higher with ZDV-3TC-lopinavir/r. No differences in outcome were observed among Swiss HIV Cohort Study sites. CONCLUSIONS Large differences in prescription but not in outcome were observed among study sites. A trend toward individualized cART was noted suggesting that initial cART is significantly influenced by physician's preference and patient characteristics. Our study highlights the need for evidence-based data for determining the best initial regimen for different HIV-infected persons.