13 resultados para testing against heavy tails

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To assess the presence of within-group comparisons with baseline in a subset of leading dental journals and to explore possible associations with a range of study characteristics including journal and study design. STUDY DESIGN AND SETTING Thirty consecutive issues of five leading dental journals were electronically searched. The conduct and reporting of statistical analysis in respect of comparisons against baseline or otherwise along with the manner of interpretation of the results were assessed. Descriptive statistics were obtained, and chi-square test and Fisher's exact were undertaken to test the association between trial characteristics and overall study interpretation. RESULTS A total of 184 studies were included with the highest proportion published in Journal of Endodontics (n = 84, 46%) and most involving a single center (n = 157, 85%). Overall, 43 studies (23%) presented interpretation of their outcomes based solely on comparisons against baseline. Inappropriate use of baseline testing was found to be less likely in interventional studies (P < 0.001). CONCLUSION Use of comparisons with baseline appears to be common among both observational and interventional research studies in dentistry. Enhanced conduct and reporting of statistical tests are required to ensure that inferences from research studies are appropriate and informative.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

REASON FOR PERFORMING STUDY: In Europe the incidence of botulism in horses has increased in the last decade due to the growing popularity of haylage feeding. Recombinant vaccines are safer and less expensive to produce and are generally better tolerated than toxoids. OBJECTIVES: To investigate whether the recombinant C-terminal half of the heavy chain of the botulinum neurotoxin C (Hc BoNT/C) in combination with an immunstimulatory adjuvant is an appropriate vaccine candidate for horses by testing its efficacy to induce neutralising antibodies and by comparing its immunogenic properties and adverse reactions to a commercial toxoid vaccine. Formation of oedema and local pain reactions were assessed. ELISA and Western blot assay against Hc BoNT/C and testing of neutralising antibody induction in a mouse protection assay were used to evaluate the immune response. RESULTS: With the recombinant vaccine, only minor local swelling with full recovery after 5 days was noted after brisket injections. The toxoid vaccine produced local, painful reactions with longer recovery periods of up to 2 weeks. Horses vaccinated with either vaccine induced neutralising antibodies after the second booster vaccination, while seroconversion on ELISA and Western blot to Hc BoNT/C was apparent after the first recombinant vaccination, and at various time points in the vaccination schedule in horses that received commercial toxoid vaccine. CONCLUSION: The recombinant vaccine showed fewer adverse reactions compared to the only commercially available vaccine but induced similar concentrations of neutralising antibodies. There was no correlation between the serological response to Hc BoNT/C and the neutralising capacity of serum. POTENTIAL RELEVANCE: Recombinant Hc BoNT/C is an appropriate vaccine candidate to stimulate production of neutralising antibodies against botulinum neurotoxin C in horses and creates only minor local reactions at the injection site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The monoclonal anti-IgE antibody omalizumab (Xolair is mostly used for the treatment of severe allergic asthma. However, the requirement of high doses and suboptimal cost-effectiveness limits the use of the treatment. Here we propose to use a new drug format based on non-immunoglobulin structures, potentially offering increased clinical efficacy while being more cost-effective. For this purpose, DARPins (designed ankyrin repeat proteins) against the constant heavy chain region of IgE have been isolated. DARPins were binding to IgE with high specificity and affinities in the low nanomolar range. Selected DARPins antagonized the interaction between IgE and its high-affinity receptor in inhibition assays. Furthermore, anti-IgE DARPins were shown to inhibit proinflammatory mediator release from rat basophilic leukemia cells expressing human high-affinity IgE receptors with higher efficacy than the monoclonal anti-IgE antibody omalizumab. DARPins may thus represent promising future drug candidates for the treatment of allergy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Recombinant allergens are preferred over natural allergen extracts in measuring antibodies. We tested the use of recombinant variants of the major mouse allergen Mus m 1 in detection of mouse-specific antibodies in sera of laboratory animal workers and children. Methods: Six recombinant major urinary proteins (MUPs) were produced and antibody-binding capacity was compared to natural Mus m 1 and to mouse urine extract. In a specific subset, cross-reactivity of MUP with Mus m 1 and between the different recombinant MUPs was determined. Results: For IgE antibodies, MUP8 showed high cross-reactivity with Mus m 1. MUP8-specific IgE was found in 55% of the mouse urine IgE-positive sera. Specific IgG and IgG4 antibodies against natural Mus m 1 correlated strongly with antibodies against recombinant MUP8 and were cross-reactive. IgG4 levels against MUP8 and mouse urine extract correlated, but detection of mouse urine-specific IgG4 in the absence of MUP-specific IgG4 was not uncommon. Cross-reactivity of IgG antibodies between MUP8 and Mus m 1 as well as between the different MUPs was high and inhibition varied between 54 and 99%. Conclusion: The mouse allergen Mus m 1 can be replaced in antibody testing by recombinant MUP8. Other MUPs, except MUP4, are interchangeable with MUP8. However, mouse urine extract showed better detection of both mouse-specific IgE and IgG4 levels. Other components in the mouse urine, like mouse albumin and other yet unidentified components, also induce IgE and IgG(4) antibodies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effectiveness of antibiotic prophylaxis against endocarditis was assessed by testing the bactericidal and bacteriostatic action in serum of 12 healthy volunteers who had taken the recommended antibiotics according to laid down guidelines. Blood was obtained from these subjects every two hours for 12 hours after oral intake of amoxicillin (3 g as a single dose), clindamycin (600 mg a single dose) or erythromycin (1.5 g plus another 0.5 g after six hours), the serum being tested against three Strep. viridans strains. Two of the three strains were "tolerant", i.e. in relation to the minimal inhibition concentration (MIC) their growth was inhibited, but--in relation to the minimal bactericidal concentration (MBC)--they were not killed. A bacteriostatic effect by amoxicillin and clindamycin was demonstrated by a micromethod against all three strains during the 12-hour period. But erythromycin did not achieve bacteriostasis in all serum samples. A bactericidal effect was demonstrated only in those samples that contained amoxicillin, and then only against the non-tolerant of the three strains. These results support the view that amoxicillin and clindamycin are effective in the prophylaxis against Strep. viridans bacteraemia because of their constant bacteriostatic effect, as measured in serum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: To assess whether the prevalence of HIV positive tests in clients at five anonymous testing sites in Switzerland had increased since the end of the 1990s, and ascertain whether there had been any concurrent change in the proportions of associated risk factors. METHODS: Baseline characteristics were analysed, by groups of years, over the eleven consecutive years of data collected from the testing sites. Numbers of HIV positive tests were presented as prevalence/1000 tests performed within each category. Multivariable analyses, stratified by African nationality and risk group of heterosexuals or men who have sex with men (MSM), were done controlling simultaneously for a series of variables. Odds ratios (ORs) were reported together with their 95% confidence intervals (CI). P values were calculated from likelihood ratio tests. RESULTS: There was an increase in the prevalence of positive tests in African heterosexuals between 1996-1999 and 2004-2006, rising from 54.2 to 86.4/1000 and from 5.6 to 25.2/1000 in females and males respectively. The proportion of MSM who knew that one or more of their sexual partners was infected with HIV increased from 2% to 17% and the proportion who reported having more than five sexual partners in the preceding two years increased from 44% to 51%. CONCLUSIONS: Surveillance data from anonymous testing sites continue to provide useful information on the changing epidemiology of HIV and thus inform public health strategies against HIV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recurrent airway obstruction (RAO) is a common condition in stabled horses characterised by small airway inflammation, airway neutrophilia and obstruction following exposure of susceptible horses to mouldy hay and straw and is thus regarded as a hypersensitivity reaction to mould spores. However, the role of IgE-mediated reactions in RAO remains unclear. The aim of the study was to investigate with a serological IgE ELISA test (Allercept), an in vitro sulfidoleukotriene (sLT) release assay (CAST) and with intradermal testing (IDT) whether serum IgE and IgE-mediated reactions against various mould, mite and pollen extracts are associated with RAO. IDT reactions were evaluated at different times in order to detect IgE-mediated immediate type reactions (type I hypersensitivity reactions, 0.5-1 h), immune complex-mediated late type reactions (type III reactions, 4-10 h) and cell-mediated delayed type reactions (type IV hypersensitivity reactions 24-48 h). In the serological test, overall the control horses displayed more positive reactions than the RAO-affected horses but the difference was not significant. Comparison of the measured IgE levels showed that the RAO-affected horses had slightly higher IgE levels against Aspergillus fumigatus than controls (35 and 16 AU, respectively, p<0.05), but all values were below the cut off (150 AU) of the test. In the sLT release assay, seven positive reactions were observed in the RAO-affected horses and four in the controls but this difference was not significant. A significantly higher proportion of late type IDT reactions was observed in RAO-affected horses compared to controls (25 of 238 possible reactions versus 12 of 238 possible reactions, respectively, p<0.05). Interestingly, four RAO-affected but none of the control horses reacted with the recombinant mould allergen A. fumigatus 8 (rAsp f 8, p<0.05), but only late phase and delayed type reactions were observed. In all three tests the majority of the positive reactions was observed with the mite extracts (64%, 74% and 88% of all positive reactions, respectively) but none of the tests showed a significant difference between RAO-affected and control animals. Our findings do not support that IgE-mediated reactions are important in the pathogenesis of RAO. Further studies are needed to investigate whether sensitisation to mite allergens is of clinical relevance in the horse and to understand the role of immune reactions against rAsp f 8.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To determine the diagnostic value of a serologic microagglutination test (MAT) and a PCR assay on urine and blood for the diagnosis of leptospirosis in dogs with acute kidney injury (AKI). DESIGN Cross-sectional study. Animals-76 dogs with AKI in a referral hospital (2008 to 2009). PROCEDURES Dogs' leptospirosis status was defined with a paired serologic MAT against a panel of 11 Leptospira serovars as leptospirosis-associated (n = 30) or nonleptospirosis-associated AKI (12). In 34 dogs, convalescent serologic testing was not possible, and leptospirosis status was classified as undetermined. The diagnostic value of the MAT single acute or convalescent blood sample was determined in dogs in which leptospirosis status could be classified. The diagnostic value of a commercially available genus-specific PCR assay was evaluated by use of 36 blood samples and 20 urine samples. RESULTS Serologic acute testing of an acute blood sample had a specificity of 100% (95% CI, 76% to 100%), a sensitivity of 50% (33% to 67%), and an accuracy of 64% (49% to 77%). Serologic testing of a convalescent blood sample had a specificity of 92% (65% to 99%), a sensitivity of 100% (87% to 100%), and an accuracy of 98% (88% to 100%). Results of the Leptospira PCR assay were negative for all samples from dogs for which leptospirosis status could be classified. CONCLUSIONS AND CLINICAL RELEVANCE Serologic MAT results were highly accurate for diagnosis of leptospirosis in dogs, despite a low sensitivity for early diagnosis. In this referral setting of dogs pretreated with antimicrobials, testing of blood and urine samples with a commercially available genus-specific PCR assay did not improve early diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Switzerland had been affected by the bluetongue virus serotype 8 (BTV-8) epidemic in Europe in the years 2007 to 2009. After three years of mandatory vaccination and comprehensive surveillance, Switzerland showed to be free of BTV-8 in 2012. In the future Elisa testing of bulk-tank milk (BTM) samples as a very sensitive and cost-effective method should be used for the surveillance of all serotypes of BTV. To determine the prevalence of seropositive herds, BTM from 240 cattle herds was sampled in July 2012. The results showed an apparent seroprevalence of 98.7% in the investigated dairy herds. Most plausible, the high prevalence was caused by the vaccination campaigns rather than by infections with BTV-8. In the outbreak the cumulative number of BTV-8 cases in Switzerland had been 75.Thus it is very likely that the used inactivated vaccines induced long-term antibody titres. Due to the high seroprevalence, investigating for BT-antibodies cannot be used for early recognition of a new introduction of BTV at the moment. Nonetheless, testing of BTM samples is appropriate for an annual evaluation of the seroprevalence and especially as an instrument for early recognition for incursions as soon as the antibody prevalence declines.To determine this decline the BTM testing scheme should be conducted each year as described in this work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The head impulse test (HIT) can identify a deficient vestibulo-ocular reflex (VOR) by the compensatory saccade (CS) generated once the head stops moving. The inward HIT is considered safer than the outward HIT, yet might have an oculomotor advantage given that the subject would presumably know the direction of head rotation. Here, we compare CS latencies following inward (presumed predictable) and outward (more unpredictable) HITs after acute unilateral vestibular nerve deafferentation. Seven patients received inward and outward HITs delivered at six consecutive postoperative days (POD) and again at POD 30. All head impulses were recorded by portable video-oculography. CS included those occurring during (covert) or after (overt) head rotation. Inward HITs included mean CS latencies (183.48 ms ± 4.47 SE) that were consistently shorter than those generated during outward HITs in the first 6 POD (p = 0.0033). Inward HITs induced more covert saccades compared to outward HITs, acutely. However, by POD 30 there were no longer any differences in latencies or proportions of CS and direction of head rotation. Patients with acute unilateral vestibular loss likely use predictive cues of head direction to elicit early CS to keep the image centered on the fovea. In acute vestibular hypofunction, inwardly applied HITs may risk a preponderance of covert saccades, yet this difference largely disappears within 30 days. Advantages of inwardly applied HITs are discussed and must be balanced against the risk of a false-negative HIT interpretation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Architectural decisions are often encoded in the form of constraints and guidelines. Non-functional requirements can be ensured by checking the conformance of the implementation against this kind of invariant. Conformance checking is often a costly and error-prone process that involves the use of multiple tools, differing in effectiveness, complexity and scope of applicability. To reduce the overall effort entailed by this activity, we propose a novel approach that supports verification of human- readable declarative rules through the use of adapted off-the-shelf tools. Our approach consists of a rule specification DSL, called Dicto, and a tool coordination framework, called Probo. The approach has been implemented in a soon to be evaluated prototype.