23 resultados para tee

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The case of a 55-year-old woman is presented, whose clinical signs were initially suggestive of infective endocarditis. Transthoracic echocardiography (TTE) provided the diagnosis of a large left atrial myxoma attached to the anterior mitral leaflet. Perioperative transesophageal echocardiography (TEE) confirmed preoperative findings and assisted the surgical team in the assessment of tumour size, area of attachment, and mobility. Following tumour resection, TEE demonstrated residual moderate mitral valve regurgitation, which resulted in a change of surgical strategy. This report reinforces the importance of intraoperative TEE to facilitate and optimize surgical and anaesthesiological management of patients presenting with non-specific cardiorespiratory symptoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

American College of Cardiology/American Heart Association guidelines for the diagnosis and management of heart failure recommend investigating exacerbating conditions such as thyroid dysfunction, but without specifying the impact of different thyroid-stimulation hormone (TSH) levels. Limited prospective data exist on the association between subclinical thyroid dysfunction and heart failure events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to test the hypothesis that ear oximetry immediately after the release of a sustained Valsalva maneuver accurately detects patent foramen ovale (PFO). One hundred sixty-five scuba divers underwent transesophageal echocardiography (TEE; reference method) for PFO assessment. Ear oximetry of the right earlobe was performed in a different room within a time frame of 2 hours before or after TEE. The subject and the oximetry operator were unaware of the results of TEE. Oxygen saturation (SO(2)) measurements were obtained at baseline and during the release phase of 4 Valsalva maneuvers within 10 minutes, and the average SO(2) change (SO(2) at baseline minus SO(2) at Valsalva release) was determined as the primary study end point. One hundred seventeen divers had no PFO, and 48 (29%) had PFO by TEE (mean age 39 ± 8 years). The average SO(2) change was 0.79 ± 1.13% (i.e., a slight absolute SO(2) decrease in response to the Valsalva maneuver) in the group without PFO and 1.67 ± 1.19% in the PFO group (p <0.0001). Using receiver-operating characteristic curve analysis, a PFO as defined by TEE could be detected at a threshold of a Valsalva-induced decrease in SO(2) of ≥0.825 percentage points in comparison to baseline (sensitivity 0.756, specificity 0.706, area under the receiver-operating characteristic curve 0.763, p <0.0001, negative predictive value 0.882). In conclusion, the entirely noninvasive method of ear oximetry in response to repetitive Valsalva maneuvers is accurate and useful as a screening method for the detection of a PFO, as shown in this study of divers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data from prospective cohort studies regarding the association between subclinical hyperthyroidism and cardiovascular outcomes are conflicting.We aimed to assess the risks of total and coronary heart disease (CHD) mortality, CHD events, and atrial fibrillation (AF) associated with endogenous subclinical hyperthyroidism among all available large prospective cohorts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The suspected cause of clinical manifestations of patent foramen ovale (PFO) is a transient or a permanent right-to-left shunt (RLS). Contrast-enhanced transcranial Doppler ultrasound (c-TCD) is a reliable alternative to transesophageal echocardiography (TEE) for diagnosis of PFO, and enables also the detection of extracardiac RLS. The air-containing echo contrast agents are injected intravenously and do not pass the pulmonary circulation. In the presence of RLS, the contrast agents bypass the pulmonary circulation and cause microembolic signals (MES) in the basal cerebral arteries, which are detected by TCD. The two main echo contrast agents in use are agitated saline and D-galactose microparticle solutions. At least one middle cerebral artery (MCA) is insonated, and the ultrasound probe is fixed with a headframe. The monitored Doppler spectra are stored for offline analysis (e.g., videotape) of the time of occurrence and number of MES, which are used to assess the size and functional relevance of the RLS. The examination is more sensitive, if both MCAs are investigated. In the case of negative testing, the examination is repeated using the Valsalva maneuver. Compared to TEE, c-TCD is more comfortable for the patient, enables an easier assessment of the size and functional relevance of the RLS, and allows also the detection of extracardiac RLS. However, c-TCD cannot localize the site of the RLS. Therefore, TEE and TCD are complementary methods and should be applied jointly in order to increase the diagnostic accuracy for detecting PFO and other types of RLS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is generally performed using intra-procedural guidance by transoesophageal (TEE) or intracardiac (ICE) echocardiography. While TEE requires sedation or general anaesthesia, ICE is costly and adds incremental risk, and both imaging modalities lengthen the procedure. METHODS: A total of 825 consecutive patients (age 51 +/- 13 years; 58% male) underwent percutaneous PFO closure solely under fluoroscopic guidance, without intra-procedural echocardiography. The indications for PFO closure were presumed paradoxical embolism in 698 patients (95% cerebral, 5% other locations), an embolic event with concurrent aetiologies in 47, diving in 51, migraine headaches in 13, and other reasons in 16. An atrial septal aneurysm was associated with the PFO in 242 patients (29%). RESULTS: Permanent device implantation failed in two patients (0.2%). There were 18 procedural complications (2.2%), including embolization of the device or parts of it in five patients with successful percutaneous removal in all cases, air embolism with transient symptoms in four patients, pericardial tamponade requiring pericardiocentesis in one patient, a transient ischaemic attack with visual symptoms in one patient, and vascular access site problems in seven patients. There were no long-term sequelae. Contrast TEE at six months showed complete abolition of right-to-left shunt via PFO in 88% of patients, whereas a minimal, moderate or large residual shunt persisted in 7%, 3%, and 2%, respectively. CONCLUSIONS: This study confirms the safety and feasibility of percutaneous PFO closure without intra-procedural echocardiographic guidance in a large cohort of consecutive patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). METHODS: Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. RESULTS: There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. CONCLUSIONS: The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a case of an intraoperative acute aortic type A dissection (AADA) extending from the distal ascending aorta to the distal aortic arch, initially not visible on the transesophageal echocardiography (TEE). The rapid confirmation of the diagnosis by means of direct epiaortic ultrasound scanning facilitated decision-making and the subsequent successful surgical treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To assess feasibility and outcomes of left atrial appendage (LAA) closure when using a patent foramen ovale (PFO) for left atrial access. Background: Because of the fear of entering the left atrium too high, using a PFO for left atrial access during LAA occlusion (LAAO) is generally discouraged. We report our single-center experience using a concomitant PFO for LAAO, thereby avoiding transseptal puncture. METHODS: LAAO was performed with local anesthesia and fluoroscopic guidance only (no echocardiography). The Amplatzer Cardiac Plug (ACP) was used in all patients. After LAAO, the PFO was closed at the same sitting, using an Amplatzer occluder through the ACP delivery sheath. Patients were discharged the same or the following day on dual antiplatelet therapy for 1-6 months, at which time a follow-up transesophageal echocardiogram (TEE) was performed. RESULTS: In 49 (96%) of 51 patients (35 males, age 70.9 ± 11.9 years), LAAO was successful using the PFO for left atrial access. In one patient, a long tunnel PFO precluded LAAO, which was performed via a more caudal transseptal puncture. In a second patient, a previously inserted ASD occluder precluded LAAO, which was abandoned because of pericardial bleeding. PFO closure was successful in all patients. Follow-up TEE was performed in 43 patients 138 ± 34 days after the procedure. It showed proper sitting of both devices in all patients. CONCLUSIONS: Using a PFO for LAAO had a high success rate and could be the default access in all patients with a PFO, potentially reducing procedural complications arising from transseptal puncture.