4 resultados para tecnologie appropriate impianti off-grid energia elettrica
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVES: The aim of this randomised clinical trial was to investigate if a laser fluorescence device is able to discriminate between sound and carious approximal sites and between enamel and dentinal lesions, as well as to find appropriate cut-off values. METHODS: One hundred and seventeen sound or uncavitated carious sites in permanent molars were visually and radiographically examined, then either opened or not, after which their laser fluorescence was measured. Forty-three lesions were opened, the caries removed and the clinically identified caries depths were registered in addition to the radiographical scoring. Seventy-four sites were radiographically deemed sound or had enamel caries and were not opened. Here, the radiographical scorings were registered. RESULTS: Taking the radiographic scoring as gold standard for all investigated approximal sites, sound sites (D(0), n=40) showed significantly lower laser fluorescence measurements than carious sites (D(1-4), n=77) (Mann-Whitney test, P<0.025) suggesting a cut-off at 7 (sensitivity=0.68, specificity=0.7). Comparing measurements of D(0-2) (n=74) and D(3,4) (n=43), the results were also different by a statistically significant amount (P<0.025) and the cut-off calculated to be 16 (sensitivity=0.6, specificity=0.84). A fair positive correlation between laser fluorescence values and radiographical scoring was found (rho=+0.47, P<0.01). Analysing the 43 opened lesions with their clinically found lesion depths as gold standard, there was a fair positive correlation to the laser fluorescence values (rho=+0.34, P=0.03) and a moderately strong correlation to the radiographic scoring (rho=+0.67, P<0.01). CONCLUSION: The device may be an adjunct tool in the approximal detection of caries along with established procedures.
Resumo:
Various assays have been used as an aid to diagnose failure of passive transfer (FPT) of immunoglobulins in neonatal foals, but often lack sensitivity as screening tests, or are time consuming to perform and impractical as confirmatory tests. The aim of the present study was to evaluate whether measurement of serum total globulins (TG; i.e. total protein minus albumin) can be used to estimate the electrophoretic gamma globulin (EGG) fraction in hospitalised neonatal foals with suspected FPT. Sample data from 56 foals were evaluated retrospectively. The coefficient of rank correlation was 0.84. The area under the curve of ROC analysis was 0.887, 0.922 and 0.930 for EGG concentrations <2 g/L, < 4 g/L and <8 g/L, respectively. Cut-offs for TG achieved ≥90% sensitivity for detecting EGG <2 g/L, < 4 g/L and <8 g/L, with negative predictive values of >97% and >94%, using prevalence of 15% and 30%, respectively. These results suggest that measurement of TG can be used as a guide to predicting EGG, provided that appropriate cut-off values are selected, and this technique could be a useful initial screening test for FPT in foals.