74 resultados para tablet-PCs (TPC)
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Purpose: Most recently light and mobile reading devices with high display resolutions have become popular and they may open new possibilities for reading applications in education, business and the private sector. The ability to adapt font size may also open new reading opportunities for people with impaired or low vision. Based on their display technology two major groups of reading devices can be distinguished. One type, predominantly found in dedicated e-book readers, uses electronic paper also known as e-Ink. Other devices, mostly multifunction tablet-PCs, are equipped with backlit LCD displays. While it has long been accepted that reading on electronic displays is slow and associated with visual fatigue, this new generation is explicitly promoted for reading. Since research has shown that, compared to reading on electronic displays, reading on paper is faster and requires fewer fixations per line, one would expect differential effects when comparing reading behaviour on e-Ink and LCD. In the present study we therefore compared experimentally how these two display types are suited for reading over an extended period of time. Methods: Participants read for several hours on either e-Ink or LCD, and different measures of reading behaviour and visual strain were regularly recorded. These dependent measures included subjective (visual) fatigue, a letter search task, reading speed, oculomotor behaviour and the pupillary light reflex. Results: Results suggested that reading on the two display types is very similar in terms of both subjective and objective measures. Conclusions: It is not the technology itself, but rather the image quality that seems crucial for reading. Compared to the visual display units used in the previous few decades, these more recent electronic displays allow for good and comfortable reading, even for extended periods of time.
Resumo:
The Liquid Argon Time Projection Chamber (LArTPC) is a prime type of detector for future large-mass neutrino observatories and proton decay searches. In this paper we present the design and operation, as well as experimental results from ARGONTUBE, a LArTPC being operated at the AEC-LHEP, University of Bern. The main goal of this detector is to prove the feasibility of charge drift over very long distances in liquid argon. Many other aspects of the LArTPC technology are also investigated, such as a voltage multiplier to generate high voltage in liquid argon (Greinacher circuit), a cryogenic purification system and the application of multi-photon ionization of liquid argon by a UV laser. For the first time, tracks induced by cosmic muons and UVlaser beam pulses have been observed and studied at drift distances of up to 5 m, the longest reached to date.
Resumo:
The Liquid Argon Time Projection Chamber (LAr TPC) technique is a promising technology for future neutrino detectors. At LHEP of the University of Bern (Switzerland), an R&D program towards large detectors are on-going. The main goal is to show the feasibility of long drift paths over many meters. Therefore, a liquid Argon TPC with 5m of drift distance was constructed. Many other aspects of the liquid Argon TPC technology are also investigated, such as a new device to generate high voltage in liquid Argon (Greinacher circuit), a recirculation filtering system and the multi-photon ionization of liquid Argon with a UV laser. Two detectors are built: a medium size prototype for specific detector technology studies, and ARGONTUBE, a 5m long device.
Resumo:
Electron recombination in highly ionizing stopping protons and deuterons is studied in the ArgoNeuT detector. The data are well modeled by either a Birks model or a modified form of the Box model. The dependence of recombination on the track angle with respect to the electric field direction is much weaker than the predictions of the Jaffe columnar theory and by theoretical-computational simulations.
Resumo:
ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron drift length of up to 5 m equipped with cryogenic charge-sensitive preamplifiers. In this work, we present results on its performance, including a comparison of the new cryogenic charge-sensitive preamplifiers with the previously used room-temperature-operated charge preamplifiers.
Resumo:
ARGONTUBE is a liquid argon time projection chamber (LAr TPC) with a drift field generated in-situ by a Greinacher voltage multiplier circuit. We present results on the measurement of the drift-field distribution inside ARGONTUBE using straight ionization tracks generated by an intense UV laser beam. Our analysis is based on a simplified model of the charging of a multi-stage Greinacher circuit to describe the voltages on the field cage rings.
Resumo:
Introduction Language is the most important mean of communication and plays a central role in our everyday life. Brain damage (e.g. stroke) can lead to acquired disorders of lan- guage affecting the four linguistic modalities (i.e. reading, writing, speech production and comprehension) in different combinations and levels of severity. Every year, more than 5000 people (Aphasie Suisse) are affected by aphasia in Switzerland alone. Since aphasia is highly individual, the level of difficulty and the content of tasks have to be adapted continuously by the speech therapists. Computer-based assignments allow patients to train independently at home and thus increasing the frequency of ther- apy. Recent developments in tablet computers have opened new opportunities to use these devices for rehabilitation purposes. Especially older people, who have no prior experience with computers, can benefit from the new technologies. Methods The aim of this project was to develop an application that enables patients to train language related tasks autonomously and, on the other hand, allows speech therapists to assign exercises to the patients and to track their results online. Seven categories with various types of assignments were implemented. The application has two parts which are separated by a user management system into a patient interface and a therapist interface. Both interfaces were evaluated using the SUS (Subject Usability Scale). The patient interface was tested by 15 healthy controls and 5 patients. For the patients, we also collected tracking data for further analysis. The therapist interface was evaluated by 5 speech therapists. Results The SUS score are xpatients = 98 and xhealthy = 92.7 (median = 95, SD = 7, 95% CI [88.8, 96.6]) in case of the patient interface and xtherapists = 68 in case of the therapist interface. Conclusion Both, the patients and the healthy subjects, attested high SUS scores to the patient interface. These scores are considered as "best imaginable". The therapist interface got a lower SUS score compared to the patient interface, but is still considered as "good" and "usable". The user tracking system and the interviews revealed that there is room for improvements and inspired new ideas for future versions.
Resumo:
In clinical medicine, plane radiography is used for detecting the remains of medications in the stomach in oral medication intoxication cases. Since postmortem computed tomography (CT), performed prior to autopsy, is currently intensively entering the forensic routine, the technique was applied to three fatal cases of oral medication intoxication. Here we report CT and autopsy findings for these cases. In all three cases, hyperdense areas within the stomach content were documented. The measurement of Hounsfield Units (HU) beyond 74HU showed mean values of 338, 88 and 98HU. Postmortem CT also showed brain edema and pulmonary aspiration in one case. At autopsy, tablet remains in the stomach were detected microscopically in all three cases. The ex vivo CT scans of the ingested medicaments showed similar HU values. Despite the fact that further case studies are necessary beyond this one, and in spite of its limitations, postmortem CT was found to be a useful screening and documentation method for stomach contents in oral medication intoxication.
Resumo:
Physicians treating patients with posterior circulation strokes (PCS) tended to debate more on whether or not to introduce anticoagulation rather than performing investigations to identify stroke aetiology, as in patients with anterior circulation strokes (ACS). Recent findings suggest that stroke aetiologies of PCS and ACS are more alike than dissimilar, suggesting that PCS deserve the same investigations as ACS. The characteristics and current diagnostic evaluation between patients with PCS and ACS were compared.
Resumo:
Intravenous thrombolysis is an approved treatment for anterior (ACS) and posterior (PCS) circulation stroke. However, no randomized controlled trial has investigated safety and efficacy of intravenous thrombolysis according to stroke territory, although PCS is assumed to differ from ACS in many ways. We aimed to compare the safety and clinical outcome of intravenous thrombolysis applied to patients with PCS and ACS.
Resumo:
SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.