46 resultados para surgery reconstruction

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Temporal hollowing due to temporal muscle atrophy after standard skull base surgery is common. Various techniques have been previously described to correct the disfiguring defect. Most often reconstruction is performed using freehand molded polymethylmethacrylate cement. This method and material are insufficient in terms of aesthetic results and implant characteristics. We herein propose reconstruction of such defects with a polyetheretherketone (PEEK)-based patient-specific implant (PSI) including soft-tissue augmentation to preserve normal facial topography. We describe a patient who presented with a large temporo-orbital hemangioma that had been repaired with polymethylmethacrylate 25 years earlier. Because of a toxic skin atrophy fistula, followed by infection and meningitis, this initial implant had to be removed. The large, disfiguring temporo-orbital defect was reconstructed with a PEEK-based PSI. The lateral orbital wall and the temporal muscle atrophy were augmented with computer-aided design and surface modeling techniques. The operative procedure to implant and adopt the reconstructed PEEK-based PSI was simple, and an excellent cosmetic outcome was achieved. The postoperative clinical course was uneventful over a 5-year follow-up period. Polyetheretherketone-based combined bony and soft contour remodeling is a feasible and effective method for cranioplasty including combined bone and soft-tissue reconstruction of temporo-orbital defects. Manual reconstruction of this cosmetically delicate area carries an exceptional risk of disfiguring results. Augmentation surgery in this anatomic location needs accurate PSIs to achieve satisfactory cosmetic results. The cosmetic outcome achieved in this case is superior compared with previously reported techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Producing a rich, personalized Web-based consultation tool for plastic surgeons and patients is challenging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Congenital pseudarthrosis of the tibia (CPT) is caused by an ill-defined, segmental disturbance of periosteal bone formation leading to spontaneous bowing, followed by fracture and subsequent pseudarthrosis in the first 2 years of life. The results of conventional treatment modalities (e.g., bracing, internal and external fixation and bone grafting) are associated with high failure rates in terms of persisting pseudarthrosis, malunion and impaired growth. As a more promising alternative, a more aggressive approach, including wide resection of the affected bone, reconstruction with free vascularised fibula grafts from the healthy contralateral leg and stable external fixation at a very early stage has been suggested. Between 1995 and 2007, 10 children (age 12-31 months, median 20 months) suffering from CPT were treated at our institutions according to this principle. Two patients were treated before a fracture had occurred. The length of the fibula graft was 7-9cm. End-to-end anastomoses were performed at the level of the distal tibia stump. The follow-up was 80 months (median, range 12 months to 12 years). Radiologic examination at 6 weeks postoperatively showed normal bone density and structure of the transplanted fibula in all cases and osseous consolidation at 19 of the 20 graft/tibia junctions. One nonunion was sucessfully treated with bone grafting and plate osteosynthesis. Pin-tract infection occurred in three patients. Five children sustained graft fractures that were successfully treated with internal or external fixation. Two patients developed diminished growth of the affected limb or foot; all others had equal limb length and shoe size. At long-term follow-up, tibialisation of the transplant had occurred, and normal gait and physical activities were possible in all children. We conclude that in spite of a relatively high complication rate and the reluctance to perform free flap surgery in infants at this young age, the present concept may successfully prevent the imminent severe sequelae associated with CPT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immediate breast reconstruction (IBR) has become an established procedure for women necessitating mastectomy. Traditionally, the nipple-areola complex (NAC) is resected during this procedure. The NAC, in turn, is a principal factor determining aesthetic outcome after breast reconstruction, and due to its particular texture and shape, a natural-looking NAC can barely be reconstructed with other tissues. The aim of this study was to assess the oncological safety as well as morbidity and aesthetic outcome after replantation of the NAC some days after IBR. Retrospective analysis of 85 patients receiving 88 mastectomies and IBR between 1998 and 2007 was conducted. NAC (n=29) or the nipple alone (n=23) were replanted 7 days (median, range 2-10 days) after IBR in 49 patients, provided the subareolar tissue was histologically negative for tumour infiltration. Local recurrence rate was assessed after 49 months (median, range 6-120 months). Aesthetic outcome was evaluated by clinical assessment during routine follow-up at least 12 months after the last intervention. Malignant involvement of the subareolar tissue was found in eight cases (9.1%). Patients qualifying for NAC replantation were in stage 0 in 29%, stage I in 15%, stage IIa in 31%, stage IIb in 17% and stage III in 8%. Total or partial necrosis occurred in 69% and 26% if the entire NAC or only the nipple were replanted, respectively (P<0.01). Depigmentation was seen in 52% and corrective surgery was done in 11 out of 52 NAC or nipple replantations. Local recurrence and isolated regional lymph node metastasis were observed in one single case each. Another 5.8% of the patients showed distant metastases. We conclude that the replantation of the NAC in IBR is oncologically safe, provided the subareolar tissue is free of tumour. However, the long-term aesthetic outcome of NAC replantation is not satisfying, which advocates replanting the nipple alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a computationally efficient and biomechanically relevant soft-tissue simulation method for cranio-maxillofacial (CMF) surgery. A template-based facial muscle reconstruction was introduced to minimize the efforts on preparing a patient-specific model. A transversely isotropic mass-tensor model (MTM) was adopted to realize the effect of directional property of facial muscles in reasonable computation time. Additionally, sliding contact around teeth and mucosa was considered for more realistic simulation. Retrospective validation study with postoperative scan of a real patient showed that there were considerable improvements in simulation accuracy by incorporating template-based facial muscle anatomy and sliding contact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Accurate three-dimensional (3D) models of lumbar vertebrae can enable image-based 3D kinematic analysis. The common approach to derive 3D models is by direct segmentation of CT or MRI datasets. However, these have the disadvantages that they are expensive, timeconsuming and/or induce high-radiation doses to the patient. In this study, we present a technique to automatically reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image. Methods Our technique is based on a hybrid 2D/3D deformable registration strategy combining a landmark-to-ray registration with a statistical shape model-based 2D/3D reconstruction scheme. Fig. 1 shows different stages of the reconstruction process. Four cadaveric lumbar spine segments (total twelve lumbar vertebrae) were used to validate the technique. To evaluate the reconstruction accuracy, the surface models reconstructed from the lateral fluoroscopic images were compared to the associated ground truth data derived from a 3D CT-scan reconstruction technique. For each case, a surface-based matching was first used to recover the scale and the rigid transformation between the reconstructed surface model Results Our technique could successfully reconstruct 3D surface models of all twelve vertebrae. After recovering the scale and the rigid transformation between the reconstructed surface models and the ground truth models, the average error of the 2D/3D surface model reconstruction over the twelve lumbar vertebrae was found to be 1.0 mm. The errors of reconstructing surface models of all twelve vertebrae are shown in Fig. 2. It was found that the mean errors of the reconstructed surface models in comparison to their associated ground truths after iterative scaled rigid registrations ranged from 0.7 mm to 1.3 mm and the rootmean squared (RMS) errors ranged from 1.0 mm to 1.7 mm. The average mean reconstruction error was found to be 1.0 mm. Conclusion An accurate, scaled 3D reconstruction of the lumbar vertebra can be obtained from a single lateral fluoroscopic image using a statistical shape model based 2D/3D reconstruction technique. Future work will focus on applying the reconstructed model for 3D kinematic analysis of lumbar vertebrae, an extension of our previously-reported imagebased kinematic analysis. The developed method also has potential applications in surgical planning and navigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Refinement in microvascular reconstructive techniques over the last 30 years has enabled an increasing number of patients to be rehabilitated for both functional and aesthetic reasons. The purpose of this study was to evaluate different microsurgical practice, including perioperative management, in Germany, Austria, and Switzerland. The DÖSAK collaborative group for Microsurgical Reconstruction developed a detailed questionnaire which was circulated to units in the three countries. The current practice of the departments was evaluated. Thirty-eight questionnaires were completed resulting in a 47.5% response rate. A considerable variation in the number of microsurgical reconstructions per year was noted. In relation to the timing of bony reconstruction, 10 hospitals did reconstructions primarily (26.3%), 19 secondarily (50%) and 9 (23.7%) hospitals used both concepts. In the postoperative course, 15.8% of hospitals use inhibitors of platelet aggregation, most hospitals use low molecular heparin (52.6%) or other heparin products (44.7%). This survey shows variation in the performance, management, and care of microsurgical reconstructions of patients. This is due in part to the microvascular surgeons available in the unit but it is also due to different types of hospitals where various types of care can be performed in these patients needing special perioperative care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this study were to evaluate the anatomic feasibility of medial patellofemoral ligament (MPFL) reconstruction using a part of the adductor magnus tendon and to identify possible risks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reconstruction of the right ventricular outflow tract plays a major role in congenital cardiac surgery. With the advent of the Contegra bovine jugular vein graft and the Shelhigh pulmonic xenograft, hopes were high that the lack of availability of homografts would be overcome. The present study evaluated both grafts and investigated the influence of known risk factors for premature graft failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate implant accuracy and cosmetic outcome of a new intraoperative patient-specific cranioplasty method after convexity meningioma resection. METHODS: The patient's own bone flap served as a template to mold a negative form with the use of polymethyl methacrylate (PMMA). The area of bone invasion was determined and broadly excised under white light illumination with a safety margin of at least 1 cm. The definitive replica was cast within the remaining bone flap frame and the imprint. Clinical and radiologic follow-up examinations were performed 3 months after surgery. RESULTS: Four women and two men (mean age 51.4 years ± 12.8) underwent reconstruction of bone flap defects after meningioma resection. Mean duration of intraoperative reconstruction of the partial bone flap defects was 19 minutes ± 4 (range 14-24 minutes). Implant sizes ranged from 17-35 cm(2) (mean size 22 cm(2) ± 8). Radiologic and clinical follow-up examinations revealed excellent implant alignment and favorable cosmesis (visual analogue scale for cosmesis [VASC] = 97 ± 5) in all patients. CONCLUSIONS: Patient-specific reconstruction of partial bone flap defects after convexity meningioma resection using the presented intraoperative PMMA cast method resulted in excellent bony alignment and a favorable cosmetic outcome. Relatively low costs and minimized operation time for adjustment and insertion of the cranioplasty implant justify use of this method in small bony defects as well.