45 resultados para spouted-bed electrode

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a theoretical assessment of the safety considerations encountered in the simultaneous use of transcranial magnetic stimulation (TMS) and neurological interventions involving implanted metallic electrodes, such as electrocorticography. Metal implants are subject to magnetic forces due to fast alternating magnetic fields produced by the TMS coil. The question of whether the mechanical movement of the implants leads to irreversible damage of brain tissue is addressed by an electromagnetic simulation which quantifies the magnitude of imposed magnetic forces. The assessment is followed by a careful mechanical analysis determining the maximum tolerable force which does not cause irreversible tissue damage. Results of this investigation provide useful information on the range of TMS stimulator output powers which can be safely used in patients having metallic implants. It is shown that conventional TMS applications can be considered safe when applied on patients with typical electrode implants as the induced stress in the brain tissue remains well below the limit of tissue damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumoral gastrin-releasing peptide (GRP) receptors are potential targets for diagnosis and therapy using radiolabeled or cytotoxic GRP analogs. GRP-receptor overexpression has been detected in endocrine-related cancer cells and, more recently, also in the vascular bed of selected tumors. More information on vascular GRP-receptors in cancer is required to asses their potential for vascular targeting applications. Therefore, frequent human cancers (n = 368) were analyzed using in vitro GRP-receptor autoradiography on tissue sections with the (125)I-[Tyr(4)]-bombesin radioligand and/or the universal radioligand (125)I-[d-Tyr(6), beta-Ala(11), Phe(13), Nle(14)]-bombesin(6-14). GRP-receptor expressing vessels were evaluated in each tumor group for prevalence, quantity (vascular score), and GRP-receptor density. Prevalence of vascular GRP-receptors was variable, ranging from 12% (prostate cancer) to 92% (urinary tract cancer). Different tumor types within a given site had divergent prevalence of vascular GRP-receptors (e.g. lung: small cell cancer: 0%; adenocarcinoma: 59%; squamous carcinoma: 83%). Also the vascular score varied widely, with the highest score in urinary tract cancer (1.69), moderate scores in lung (0.91), colon (0.88), kidney (0.84), and biliary tract (0.69) cancers and low scores in breast (0.39) and prostate (0.14) cancers. Vascular GRP-receptors were expressed in the muscular vessel wall in moderate to high densities. Normal non-neoplastic control tissues from these organs lacked vascular GRP-receptors. In conclusion, tumoral vessels in all evaluated sites express GRP-receptors, suggesting a major biological function of GRP-receptors in neovasculature. Vascular GRP-receptor expression varies between the tumor types indicating tumor-specific mechanisms in their regulation. Urinary tract cancers express vascular GRP-receptors so abundantly, that they are promising candidates for vascular targeting applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To develop and evaluate the psychometric properties of a measure of motivation and life outlook (Getting-Out-of-Bed [GoB]). DESIGN: Secondary analysis of baseline and 6-month data from a longitudinal follow-up study of older breast cancer survivors. PARTICIPANTS: Women (N = 660) diagnosed with primary breast cancer stage I-IIIA disease, age >or=65 years, and permission to contact from an attending physician in four geographic regions in the United States (city-based Los Angeles, California; statewide in Minnesota, North Carolina, and Rhode Island). MEASUREMENT: Data were collected over 6-months of follow-up from consenting patients' medical records and telephone interviews with patients. Data collected included the 4-item GoB, health-related quality of life (HRQoL), breast cancer, sociodemographic, and health-related characteristics. RESULTS: Factor analysis produced, as hypothesized, one principal component with eigen values of 2.74(baseline) and 2.91(6-months) which explained 68.6%(baseline) and 72.7%(6-months) of total variance. In further psychometric analyses, GoB exhibited good construct validity (divergent: low nonstatistically significant correlations with unrelated constructs; convergent: moderate statistically significant correlations with related constructs; discriminant: distinguished high HRQoL groups with a high level of significance), excellent internal reliability (Cronbach's alpha 0.84(baseline), 0.87(6-months)), and produced stable measurements over 6-months. Women with GoB scores >or=50 at baseline were more likely at 6-months to have good HRQoL, good self-perceived health, and report regular exercise, indicating good predictive ability. CONCLUSION: GoB demonstrated overall good psychometric properties in this sample of older breast cancer survivors, suggestive of a promising tool for assessing motivation and life outlook in older adults. Nevertheless, because it was developed and initially evaluated in a select sample, using measures with similar but not exact content overlap further evaluation is needed before it can be recommended for widespread use.