92 resultados para spin relaxation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a study of the model spin-glass LiHo0.5Er0.5F4 using simultaneous ac susceptibility, magnetization, and magnetocaloric effect measurements along with small angle neutron scattering (SANS) at sub-Kelvin temperatures. All measured bulk quantities reveal hysteretic behavior when the field is applied along the crystallographic c axis. Furthermore, avalanchelike relaxation is observed in a static field after ramping from the zero-field-cooled state up to 200–300 Oe. SANS measurements are employed to track the microscopic spin reconfiguration throughout both the hysteresis loop and the related relaxation. Comparing the SANS data to inhomogeneous mean-field calculations performed on a box of one million unit cells provides a real-space picture of the spin configuration. We discover that the avalanche is being driven by released Zeeman energy, which heats the sample and creates positive feedback, continuing the avalanche. The combination of SANS and mean-field simulations reveal that the conventional distribution of cluster sizes is replaced by one with a depletion of intermediate cluster sizes for much of the hysteresis loop.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE Little data is available on noninvasive MRI-based assessment of renal function during upper urinary tract (UUT) obstruction. In this study, we determined whether functional multiparametric kidney MRI is able to monitor treatment response in acute unilateral UUT obstruction. MATERIAL AND METHODS Between 01/2008 and 01/2010, 18 patients with acute unilateral UUT obstruction due to calculi were prospectively enrolled to undergo kidney MRI with conventional, blood oxygen level-dependent (BOLD) and diffusion-weighted (DW) sequences on emergency admission and after release of obstruction. Functional imaging parameters of the obstructed and contralateral unobstructed kidneys derived from BOLD (apparent spin relaxation rate [R2*]) and DW (total apparent diffusion coefficient [ADCT], pure diffusion coefficient [ADCD] and perfusion fraction [FP]) sequences were assessed during acute UUT obstruction and after its release. RESULTS During acute obstruction, R2* and FP values were lower in the cortex (p=0.020 and p=0.031, respectively) and medulla (p=0.012 and p=0.190, respectively) of the obstructed compared to the contralateral unobstructed kidneys. After release of obstruction, R2* and FP values increased both in the cortex (p=0.016 and p=0.004, respectively) and medulla (p=0.071 and p=0.044, respectively) of the formerly obstructed kidneys to values similar to those found in the contralateral kidneys. ADCT and ADCD values did not significantly differ between obstructed and contralateral unobstructed kidneys during or after obstruction. CONCLUSIONS In our patients with acute unilateral UUT obstruction due to calculi, functional kidney MRI using BOLD and DW sequences allowed for the monitoring of pathophysiologic changes of obstructed kidneys during obstruction and after its release.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The preparations, X-ray structures, and magnetic characterizations are presented for two new pentadecanuclear cluster compounds:  [NiII{NiII(MeOH)3}8(μ-CN)30{MV(CN)3}6]·xMeOH·yH2O (MV = MoV (1) with x = 17, y = 1; MV = WV (2) with x = 15, y = 0). Both compounds crystallize in the monoclinic space group C2/c, with cell dimensions of a = 28.4957(18) Å, b = 19.2583(10) Å, c = 32.4279(17) Å, β = 113.155(6)°, and Z = 4 for 1 and a = 28.5278(16) Å, b = 19.2008(18) Å, c = 32.4072(17) Å, β = 113.727(6)°, and Z = 4 for 2. The structures of 1 and 2 consist of neutral cluster complexes comprising 15 metal ions, 9 NiII and 6 MV, all linked by μ-cyano ligands. Magnetic susceptibilities and magnetization measurements of compounds 1 and 2 in the crystalline and dissolved state indicate that these clusters have a S = 12 ground state, originating from intracluster ferromagnetic exchange interactions between the μ-cyano-bridged metal ions of the type NiII−NC−MV. Indeed, these data show clearly that the cluster molecules stay intact in solution. Ac magnetic susceptibility measurements reveal that the cluster compounds exhibit magnetic susceptibility relaxation phenomena at low temperatures since, with nonzero dc fields, χ‘ ‘M has a nonzero value that is frequency dependent. However, there appears no out-of-phase (χ‘ ‘M) signal in zero dc field down to 1.8 K, which excludes the expected signature for a single molecule magnet. This finding is confirmed with the small uniaxial magnetic anisotropy value for D of 0.015 cm-1, deduced from the high-field, high-frequency EPR measurement, which distinctly reveals a positive sign in D. Obviously, the overall magnetic anisotropy of the compounds is too low, and this may be a consequence of a small single ion magnetic anisotropy combined with the highly symmetric arrangement of the metal ions in the cluster molecule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To (1) establish the feasibility of texture analysis for the in vivo assessment of biochemical changes in meniscal tissue on delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC), and (2) compare textural with conventional T1 relaxation time measurements calculated from dGEMRIC data ("T1(Gd) relaxation times").

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To prospectively determine on T2 cartilage maps the effect of unloading during a clinical magnetic resonance (MR) examination in the postoperative follow-up of patients after matrix-associated autologous chondrocyte transplantation (MACT) of the knee joint. Materials and Methods: Ethical approval for this study was provided by the local ethics commission, and written informed consent was obtained. Thirty patients (mean age, 35.4 years +/- 10.5) with a mean postoperative follow-up period of 29.1 months +/- 24.4 were enrolled. A multiecho spin-echo T2-weighted sequence was performed at the beginning (early unloading) and end (late unloading) of the MR examination, with an interval of 45 minutes. Mean and zonal region of interest T2 measurements were obtained in control cartilage and cartilage repair tissue. Statistical analysis of variance was performed. Results: The change in T2 values of control cartilage (early unloading, 50.2 msec +/- 8.4; late unloading, 51.3 msec +/- 8.5) was less pronounced than the change in T2 values of cartilage repair tissue (early unloading, 51.8 msec +/- 11.7; late unloading, 56.1 msec +/- 14.4) (P = .024). The difference between control cartilage and cartilage repair tissue was not significant for early unloading (P = .314) but was significant for late unloading (P = .036). Zonal T2 measurements revealed a higher dependency on unloading for the superficial cartilage layer. Conclusion: Our results suggest that T2 relaxation can be used to assess early and late unloading values of articular cartilage in a clinical setting and that the time point of the quantitative T2 measurement affects the differentiation between native and abnormal articular cartilage. (c) RSNA, 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose was to investigate the in vivo effects of unloading and compression on T1-Gd relaxation times in healthy articular knee cartilage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of water suppression for in vivo proton MR spectroscopy diminishes the signal intensities from resonances that undergo magnetization exchange with water, particularly those downfield of water. To investigate these exchangeable resonances, an inversion transfer experiment was performed using the metabolite cycling technique for non-water-suppressed MR spectroscopy from a large brain voxel in 11 healthy volunteers at 3.0 T. The exchange rates of the most prominent peaks downfield of water were found to range from 0.5 to 8.9 s(-1), while the T(1) relaxation times in absence of exchange were found to range from 175 to 525 ms. These findings may help toward the assignments of the downfield resonances and a better understanding of the sources of contrast in chemical exchange saturation transfer imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

T2 mapping techniques use the relaxation constant as an indirect marker of cartilage structure, and the relaxation constant has also been shown to be a sensitive parameter for cartilage evaluation. As a possible additional robust biomarker, T2* relaxation time is a potential, clinically feasible parameter for the biochemical evaluation of articular cartilage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuroimaging using magnetic resonance imaging (MRI) is required for the investigation of surgically intractable epilepsy. In addition to the standard MRI techniques, perfusion sequences can be added to improve visualization of the underlying pathological changes. Also, as arterial spin-labeling (ASL) MRI perfusion does not require contrast administration, it may even be advantageous in these patients. We report here on three patients with epilepsy and tuberous sclerosis who underwent brain MRI with ASL and positron emission tomography (PET), both of which were found to correlate with each other and with electrophysiological data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose: In acute stroke it is no longer sufficient to detect simply ischemia, but also to try to evaluate reperfusion/recanalization status and predict eventual hemorrhagic transformation. Arterial spin labeling (ASL) perfusion may have advantages over contrast-enhanced perfusion-weighted imaging (cePWI), and susceptibility weighted imaging (SWI) has an intrinsic sensitivity to paramagnetic effects in addition to its ability to detect small areas of bleeding and hemorrhage. We want to determine here if their combined use in acute stroke and stroke follow-up at 3T could bring new insight into the diagnosis and prognosis of stroke leading to eventual improved patient management. Methods: We prospectively examined 41 patients admitted for acute stroke (NIHSS >1). Early imaging was performed between 1 h and 2 weeks. The imaging protocol included ASL, cePWI, SWI, T2 and diffusion tensor imaging (DTI), in addition to standard stroke protocol. Results: We saw four kinds of imaging patterns based on ASL and SWI: patients with either hypoperfusion and hyperperfusion on ASL with or without changes on SWI. Hyperperfusion was observed on ASL in 12/41 cases, with hyperperfusion status that was not evident on conventional cePWI images. Signs of hemorrhage or blood-brain barrier breakdown were visible on SWI in 15/41 cases, not always resulting in poor outcome (2/15 were scored mRS = 0–6). Early SWI changes, together with hypoperfusion, were associated with the occurrence of hemorrhage. Hyperperfusion on ASL, even when associated with hemorrhage detected on SWI, resulted in good outcome. Hyperperfusion predicted a better outcome than hypoperfusion (p = 0.0148). Conclusions: ASL is able to detect acute-stage hyperperfusion corresponding to luxury perfusion previously reported by PET studies. The presence of hyperperfusion on ASL-type perfusion seems indicative of reperfusion/collateral flow that is protective of hemorrhagic transformation and a marker of favorable tissue outcome. The combination of hypoperfusion and changes on SWI seems on the other hand to predict hemorrhage and/or poor outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Magnetic resonance imaging (MRI) is required for the investigation of surgically intractable epilepsy. In addition to the standard MRI techniques, perfusion sequences can be added to improve visualization of underlying pathological changes. Arterial spin-labeling (ASL) MRI perfusion does not require contrast administration and, for this reason, may have advantages in these patients. METHODS: We report here on 16 patients with epilepsy who underwent MRI of the brain with ASL and positron emission tomography (PET). RESULTS: Despite a slightly reduced resolution with ASL, we found a correlation between ASL, PET and electrophysiological data, with hypoperfusion on ASL that corresponded with hypoperfusion on interictal PET. CONCLUSION: Given the correlation between ASL and PET and electrophysiology, perfusion with ASL could become part of the standard work-up in patients with epilepsy.