19 resultados para solution and solubility

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Euro-Collins solution (EC) is routinely used in lung transplantation. The high potassium of EC, however, may damage the vascular endothelium, thereby contributing to postischemic reperfusion injury. To assess the influence of the potassium concentration on lung preservation, we evaluated the effect of a "low potassium Euro-Collins solution" (LPEC), in which the sodium and potassium concentrations were reversed. METHODS: In an extracorporeal rat heart-lung model lungs were preserved with EC and LPEC. The heart-lung blocks (HLB) were perfused with Krebs-Henseleit solution containing washed bovine red blood cells and ventilated with room air. The lungs were perfused via the working right ventricle with deoxygenated perfusate. Oxygenation and pulmonary vascular resistance (PVR) were monitored. After baseline measurements, hearts were arrested with St. Thomas' solution and the lungs were perfused with EC or LPEC, or were not perfused (controls). The HLBs were stored for 5 min or 2 h ischemic time at 4 degrees C. Reperfusion and ventilation was performed for 40 min. At the end of the trial the wet/dry ratio of the lungs was calculated and light microscopic assessment of the degree of edema was performed. RESULTS: After 5 min of ischemia oxygenation was significantly better in both preserved groups compared to the controls. Pulmonary vascular resistance was elevated in all three groups after 30 min reperfusion at both ischemic times. After 2 h of ischemia PVR of the group preserved with LPEC was significantly lower than those of the EC and controls (LPEC-5 min: 184 +/- 65 dynes * sec * cm-5, EC-5 min: 275 +/- 119 dynes * sec * cm * cm-5, LPEC-2 h: 324 +/- 47 dynes * sec * m-5, EC-2 h: 507 +/- 83 dynes * sec * cm-5). Oxygenation after 2 h of ischemia and 30 min reperfusion was significantly better in the LPEC group compared to EC and controls (LPEC: 70 +/- 17 mmHg, EC: 44 +/- 3 mmHg). The wet/dry ratio was significantly lower in the two preserved groups compared to controls (LPEC-5 min: 5.7 +/- 0.7, EC-5 min: 5.8 +/- 1.2, controls-5 min: 7.5 +/- 1.8, LPEC-2 h: 6.7 +/- 0.4, EC: 6.9 +/- 0.4, controls-2 h: 7.3 +/- 0.4). CONCLUSIONS: We thus conclude that LPEC results in better oxygenation and lower PVR in this lung preservation model. A low potassium concentration in lung preservation solutions may help in reducing the incidence of early graft dysfunction following lung transplantation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Respiratory type-IV hypersensitivity reactions due to corticosteroids is a rare phenomenon. We describe two such cases. The first is a 37- year-old atopic woman who developed labial angioedema and nasal itching after the use of budesonide nasal spray. A month later, after the first puffs of a formoterol/budesonide spray prescribed for asthma, she noticed symptoms of tongue and oropharyngeal itching and redness with subsequent dysphagia, labial and tongue angioedema, and facial oedema. The second is a 15-year-old non-atopic woman who reported pruritic eruptions around the nostrils after using a budesonide nasal spray. A year later she presented with nasal pruritus with intense congestion and labial and facial oedema after using the same spray. Both patients were evaluated with patch-tests using the commercial T.R.U.E. test, a budesonide solution, and corticosteroid creams. Test evaluation was performed at 48 and 96 hours. In both patients, patch tests were positive to budesonide (++) on the second day. The first patient also had a positive (+) reaction to tixocortol-21-pivalate. All the other patch tests were negative. Clinicians should be aware that hypersensitivity reactions may occur during the use of nasal or inhaled corticosteroids.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The first part of this three-part review on the relevance of laboratory testing of composites and adhesives deals with approval requirements for composite materials. We compare the in vivo and in vitro literature data and discuss the relevance of in vitro analyses. The standardized ISO protocols are presented, with a focus on the evaluation of physical parameters. These tests all have a standardized protocol that describes the entire test set-up. The tests analyse flexural strength, depth of cure, susceptibility to ambient light, color stability, water sorption and solubility, and radiopacity. Some tests have a clinical correlation. A high flexural strength, for instance, decreases the risk of fractures of the marginal ridge in posterior restorations and incisal edge build-ups of restored anterior teeth. Other tests do not have a clinical correlation or the threshold values are too low, which results in an approval of materials that show inferior clinical properties (e.g., radiopacity). It is advantageous to know the test set-ups and the ideal threshold values to correctly interpret the material data. Overall, however, laboratory assessment alone cannot ensure the clinical success of a product.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the study was to evaluate the impact of smoking on a prolongated chlorhexidine digluconate regimen after scaling and root planing. Forty-two smokers (test group) and 85 nonsmoking patients (control group) with generalized chronic periodontitis were examined for clinical attachment level (CAL), probing depth (PD), bleeding on probing (BoP), and Plaque Index (Pl) at baseline and after 1 and 3 months. During scaling and root planing, a 0.2% chlorhexidine digluconate solution and a 1% chlorhexidine digluconate gel were used. The subjects used a 0.2% chlorhexidine digluconate solution twice daily for 3 months. The Mann-Whitney U and Wilcoxon tests were used for statistical analysis. There were significant improvements of all studied variables after 1 and 3 months in both groups. After 3 months, the mean improvement in the test group was 1.62 mm for CAL, 2.85 mm for PD, and 48% for BoP; in the control group, the values were 2.18 mm for CAL, 2.81 mm for PD, and 47% for BoP. Only the maximum changes of CAL between 1 and 3 months (test group, 0.32 mm vs 0.69 mm in the control group) and PD (test group, 0.47 mm vs 0.76 mm in the control group) were significantly different between the groups (P < .05 and P = .05, respectively). The present data appear to suggest that the use of chlorhexidine digluconate twice daily during a period of 3 months following nonsurgical periodontal therapy may result in significant clinical improvements in smokers and nonsmokers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The existence of racemic compounds, comprised of pairs of opposite enantiomers as discrete molecular entities, has been accepted for over a century. However, their ability to remain as associated dimers when in solution is uncertain, if not generally doubted. In this article, data has been assembled to provide evidence for the presence of intact dimeric heterochiral assemblies in solution and presents DL-thalidomide as a probable example of this phenomenon.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this comparative study was to investigate the development of clinical signs and accompanying haematological, coproscopic and pathological findings as a basis for the monitoring of health condition of Angiostrongylus vasorum infected dogs. Six beagles were orally inoculated with 50 (n=3) or 500 (n=3) A. vasorum third stage larvae (L3) obtained from experimentally infected Biomphalaria glabrata snails. Two dogs were treated with moxidectin/imidacloprid spot-on solution and two further dogs with an oral experimental compound 92 days post infection (dpi), and were necropsied 166 dpi. Two untreated control dogs were necropsied 97 dpi. Prepatency was 47-49 days. Dogs inoculated with 500 L3 exhibited earlier (from 42 dpi) and more severe respiratory signs. Clinical signs resolved 12 days after treatment and larval excretion stopped within 20 days in all four treated dogs. Upon necropsy, 10 and 170 adult worms were recovered from the untreated dogs inoculated with 50 and 500 L3, respectively. Adult worms were also found in two treated dogs, in the absence of L1 or eggs. Despite heavy A. vasorum infection load and severe pulmonary changes including vascular thrombosis, only mild haematological changes were observed. Eosinophilia was absent but the presence of plasma cells was observed. Neutrophilic leucocytes showed a transient increase but only after treatment. Signs for coagulopathies were slight; nevertheless coagulation parameters were inoculation dose dependent. Ten weeks after treatment pulmonary fibrosis was still present. Infections starting from 50 L3 of A. vasorum had a massive impact on lung tissues and therefore on the health of affected dogs, particularly after prepatency, although only mild haematological abnormalities were evident.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Carnoy's solution is applied to reduce the recurrence of odontogenic keratocysts and unicystic ameloblastomas. The deleterious action of this fixative on nerves has been studied but no attention has been paid to its effects on nearby vessels. The aim of this study was to investigate the effects of Carnoy's solution on blood vessels. The rat axillary artery and vein were surgically exposed, soaked with Carnoy's solution and kept in place for 2, 5 or 10 min, depending on the treatment group. The 5-min group was followed for 1, 2 and 3 weeks postoperatively. The vessels in the 2-min and 5-min exposure groups showed histological changes to the vessels, represented by focal loss of the endothelium and hyalinization of the wall. These alterations increased in the 10-min group. The vessels in the 3-week observation period revealed signs of recovery. It is concluded that Carnoy's solution can damage blood vessels but the process is reversible for exposure times less than 5 min.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: Reperfusion injury is the main reason for early graft failure after lung transplantation. Inhibition of the adherence of polymorphonuclear leukocytes to activated endothelium by blocking L- and E-selectins (antibody EL-246) could potentially inhibit reperfusion injury. METHODS: Reperfusion injury was induced in a left lung autotransplant model in sheep. After hilar stripping the left lung was flushed with Euro-Collins solution and preserved for 2 h in situ at 15 degrees C. After reperfusion right main bronchus and pulmonary artery were occluded leaving the animal dependent on the reperfused lung (control, n = 6). Pulmonary function was assessed by alveolo-arterial oxygen difference (AaDO2) and pulmonary vascular resistance (PVR), the chemiluminescence of isolated neutrophils, as well as the release of beta-N-acetyl-glucosaminidase (beta-NAG) served as indicator of neutrophilic activation. Extravascular lung water was an indicator for pulmonary edema formation. EL-246 group animals (n = 6) were treated additionally with 1 mg/kg BW of EL-246 given prior and during reperfusion. RESULTS: After 3 h of reperfusion five control animals developed alveolar edema compared to one animal in the EL-246 group (P = 0.08). AaDO2 (mm Hg) was significantly higher in the control compared to the EL-246 group (510 +/- 148 vs. 214 +/- 86). PVR (dyn x s x cm(-5)) was significantly increased in the control compared to the EL-246 group (656 +/- 240 vs. 317 +/- 87). Neutrophilic activation was significantly lower in the EL-246 group. Extravascular lung water was significantly lower compared to control (6.88 +/- 1.0 vs. 13.4 +/- 2.8 g/g blood-free lung weight). CONCLUSIONS: Treatment with EL-246 results in improved pulmonary function and less in vivo PMN activation in this experimental model. Further studies are necessary to evaluate the possible role of selectin blockade in amelioration of reperfusion injury in human lung transplantation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Potentized antimony is traditionally used in anthroposophic medicine to enhance hemostasis in bleeding disorders, but evidence of its effectiveness is scarce. On the other hand, non-toxic and economic additional therapeutic options for hemostatic disorders are desirable. OBJECTIVES: We examined all available literature on the subject and performed a controlled pilot in vitro study to test the procoagulatory potency of antimony D 5. DESIGN: Freshly drawn citrated whole blood of 12 healthy volunteers and 12 patients with bleeding disorders was equally distributed into 344 portions, after which it was mixed with antimony D 5, or its potentized vehicle (lactose D 5) as control solution and tested with thrombelastography. The paired t-test and the Wilcoxon signed rank test were used for statistical analysis. In 5 of the 12 healthy donors, a second blood sample was drawn to assess individual variability and increase the total number of replicates. Thus three separate calculations were performed: for the 12 patients, the 12 healthy donors, and the 5 later samples from the same donors. The analysis was exploratory, and no Bonferroni correction was applied. RESULTS: In the antimony D5 samples of the 12 healthy subjects, but not the patients, there was a tendency toward a shorter clotting time (CT) (p = 0.074) and a trend for an increased clot firmness, expressed as maximal amplitude (MA) (p = 0.058). The increase of MA was significant (p = 0.011) when the later samples were included. No statistical difference was detected for the clot formation time and the clot lysis index. CONCLUSION: The exploratory results of this pilot study are inconclusive as to whether antimony D5 has a procoagulatory effect in vitro, although the results suggest an effect on MA and possibly CT. More research is warranted.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVES To evaluate the effect of a tin-containing fluoride (Sn/F) mouth rinse on microtensile bond strength (μTBS) between resin composite and erosively demineralised dentin. MATERIALS AND METHODS Dentin of 120 human molars was erosively demineralised using a 10-day cyclic de- and remineralisation model. For 40 molars, the model comprised erosive demineralisation only; for another 40, the model included treatment with a NaF solution; and for yet another 40, the model included treatment with a Sn/F mouth rinse. In half of these molars (n = 20), the demineralised organic matrix was continuously removed by collagenase. Silicon carbide paper-ground, non-erosively demineralised molars served as control (n = 20). Subsequently, μTBS of Clearfil SE/Filtek Z250 to the dentin was measured, and failure mode was determined. Additionally, surfaces were evaluated using SEM and EDX. RESULTS Compared to the non-erosively demineralised control, erosive demineralisation resulted in significantly lower μTBS regardless of the removal of demineralised organic matrix. Treatment with NaF increased μTBS, but the level of μTBS obtained by the non-erosively demineralised control was only reached when the demineralised organic matrix had been removed. The Sn/F mouth rinse together with removal of demineralised organic matrix led to significantly higher µTBS than did the non-erosively demineralised control. The Sn/F mouth rinse yielded higher μTBS than did the NaF solution. CONCLUSIONS Treatment of erosively demineralised dentin with a NaF solution or a Sn/F mouth rinse increased the bond strength of resin composite. CLINICAL RELEVANCE Bond strength of resin composite to eroded dentin was not negatively influenced by treatment with a tin-containing fluoride mouth rinse.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION The objective of this systematic review was to assess the short- and long-term release of components of orthodontic adhesives and polycarbonate brackets in the oral environment. METHODS Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and PubMed), EMBASE (via Ovid), Cochrane Oral Health Group's Trials Register, and CENTRAL. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, and Pro-Quest Dissertation Abstracts and Thesis database. The reference lists of all eligible studies were checked for additional studies. Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion or the involvement of an arbiter. RESULTS No randomized controlled trial was identified. In the absence of randomized controlled trials, observational studies were included. Eleven studies met the inclusion criteria. All were observational studies conducted in vivo or in vitro. The bisphenol-A release from orthodontic bonding resins was found to be between 0.85 and 20.88 ng per milliliter in vivo, and from traces to 65.67 ppm in vitro. Polycarbonate brackets released amounts of 22.24 μg per gram in ethanol solution and 697 μg per gram after 40 months in water. Bis-GMA and TEGDMA leaching in vitro reached levels of 64 and 174 mg per 10 μL, respectively. Because of the heterogeneity in methodologies and reporting, only qualitative synthesis was performed. CONCLUSIONS The available evidence on this topic derived from observational in-vivo and in-vitro studies that represent a moderate level of evidence. The variety of setups and the different units allied to the diversity of reporting among studies did not allow calculation of pooled estimates.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Periprosthetic joint infection (PJI) is the most severe complication, following joint arthroplasty. Identification of the causal microbial factor is of paramount importance for the successful treatment. PURPOSE The aim of this study is to compare the sonication fluid cultures derived from joint prosthetic components with the respective periprosthetic tissue cultures. METHODS Explanted prosthesis components for suspected infection were placed into a tank containing sterile Ringer's solution and sonicated for 1 minute at 40 kHz. Sonication fluid cultures were examined for 10 days, and the number and identity of any colony morphology was recorded. In addition, periprosthetic tissue specimens (>5) were collected and cultured according to standard practice. The duration of antimicrobial interruption interval before culture sampling was recorded. RESULTS Thirty-four patients composed the study group. Sonication fluid cultures were positive in 24 patients (70.5%). Sixteen of thirty four periprosthetic tissue cultures (47.1%) were considered positive, all revealing the same microbial species with the respective sonication fluid cultures: 3 tissue samples showed polymicrobial infection. All tissue cultures were also found positive by the sonication fluid culture. CONCLUSIONS Sonication fluid cultures represent a cheap, easy, accurate, and sensitive diagnostic modality demonstrating increased sensitivity compared to periprosthetic tissue cultures (70.5 versus 47.1%).