Resumo:
RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.
Resumo:
OBJECTIVES: The aim of this phantom study was to evaluate the contrast-to-noise ratio (CNR) in pulmonary computed tomography (CT)-angiography for 300 and 400 mg iodine/mL contrast media using variable x-ray tube parameters and patient sizes. We also analyzed the possible strategies of dose reduction in patients with different sizes. MATERIALS AND METHODS: The segmental pulmonary arteries were simulated by plastic tubes filled with 1:30 diluted solutions of 300 and 400 mg iodine/mL contrast media in a chest phantom mimicking thick, intermediate, and thin patients. Volume scanning was done with a CT scanner at 80, 100, 120, and 140 kVp. Tube current-time products (mAs) varied between 50 and 120% of the optimal value given by the built-in automatic dose optimization protocol. Attenuation values and CNR for both contrast media were evaluated and compared with the volume CT dose index (CTDI(vol)). Figure of merit, calculated as CNR/CTDIvol, was used to quantify image quality improvement per exposure risk to the patient. RESULTS: Attenuation of iodinated contrast media increased both with decreasing tube voltage and patient size. A CTDIvol reduction by 44% was achieved in the thin phantom with the use of 80 instead of 140 kVp without deterioration of CNR. Figure of merit correlated with kVp in the thin phantom (r = -0.897 to -0.999; P < 0.05) but not in the intermediate and thick phantoms (P = 0.09-0.71), reflecting a decreasing benefit of tube voltage reduction on image quality as the thickness of the phantom increased. Compared with the 300 mg iodine/mL concentration, the same CNR for 400 mg iodine/mL contrast medium was achieved at a lower CTDIvol by 18 to 40%, depending on phantom size and applied tube voltage. CONCLUSIONS: Low kVp protocols for pulmonary embolism are potentially advantageous especially in thin and, to a lesser extent, in intermediate patients. Thin patients profit from low voltage protocols preserving a good CNR at a lower exposure. The use of 80 kVp in obese patients may be problematic because of the limitation of the tube current available, reduced CNR, and high skin dose. The high CNR of the 400 mg iodine/mL contrast medium together with lower tube energy and/or current can be used for exposure reduction.
Resumo:
AIM: To study prospectively patients after heart transplantation with respect to quality of life, mortality, morbidity, and clinical parameters before and up to 10 years after the operation. METHODS: Sixty patients (47.9 +/- 10.9 years, 57 men, 3 women) were transplanted at the University of Vienna Hospital, Department for Heart and Thorax Surgery and were included in this study. They were assessed when set on the waiting list, then exactly one, 5 and 10 years after the transplantation. The variables evaluated included physical and emotional complaints, well-being, mortality and morbidity. In the sample of patients who survived 10 years (n = 23), morbidity (infections, malignancies, graft arteriosclerosis, and rejection episodes) as well as quality of life were evaluated. RESULTS: Actuarial survival rates were 83.3, 66.7, 48.3% at 1, 5, and 10 years after transplantation, respectively. During the first year, infections were the most important reasons for premature death. As a cause of mortality, malignancies were found between years 1 and 5, and graft arteriosclerosis between years 5 and 10. Physical complaints diminished significantly after the operation, but grew significantly during the period from 5 to 10 years (p < 0.001). However, trembling (p < 0.05) and paraesthesies (p < 0.01) diminished continuously. Emotional complaints such as depression and dysphoria (both p < 0.05) increased until the tenth year after their nadir at year 1. In long-time survivors, 3 malignancies (lung, skin, thyroidea) were diagnosed 6 to 9 years postoperatively. Three patients (13%) had signs of graft arteriosclerosis at year 10; 9 (40%) patients suffered from rejection episodes during the course of 10 years. There were no serious rejection episodes deserving immediate therapy. Quality of life at 10 years is good in these patients. CONCLUSIONS: Heart transplantation is a successful therapy for patients with terminal heart disease. Long-term survivors feel well after 10 years and report a good quality of life.
Resumo:
OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.
Resumo:
BACKGROUND Hand eczema has a high impact on patients' quality of life. The treatment focuses on improving skin barrier function. OBJECTIVES To evaluate the effects and acceptance of a novel educational program for patients with hand eczema. METHODS Retrospectively, the records of 36 patients who attended the prevention program and follow-up visits were analyzed. Physician global assessment (PGA) scores, acceptance and behavioral changes were assessed. RESULTS In 67% of patients, an improvement of the hand eczema could be attributed to the effects of our educational program. The mean PGA score significantly decreased from 3 before education to 2.2 during follow-up. Behavioral changes in both skin care and protection were reported in 81 and 86%, respectively. CONCLUSIONs: Our educational program had a positive effect on clinical outcome as well as adherence to skin care and protection measures. Its integration in a hand eczema clinic was feasible and well accepted by the patients.