31 resultados para single-blind method

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. MATERIALS AND METHODS: A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. RESULTS: Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). CONCLUSIONS: For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intramyocellular acetylcarnitine (IMAC) is involved in exercise-related fuel metabolism. It is not known whether levels of systemic glucose influence IMAC levels in type 1 diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Switzerland, children are prescribed 7.5-12.5 μg per day of vitamin D(3) dissolved in alcohol, but many families do not adhere to the recommendation. The aim of the trial was to compare the acceptance of vitamin D(3) dissolved in alcohol or in medium-chain triglycerides among mothers of Swiss newborn infants. The acceptance was tested in 42 healthy newborn infants (20 girls and 22 boys) aged between 2 and 7 days. Their neonatal body weight ranged between 2.225 and 4.150 kg, and the gestational age between 36 1/7 and 41 3/7 weeks. The blinded mothers rated the facial reaction of their children by pointing on a facial hedonic scale. Thirty eight of the 41 mothers, who brought the comparison to completion, assigned a better score to the oily preparation with no difference in the remaining three cases (P < 0.0001). The acceptance for the oily preparation was significantly better both among mothers whose babies were initially presented the alcoholic preparation and among mothers whose babies were initially presented the oily preparation. Furthermore, the acceptance for the oily preparation was better irrespective of gender of the infant or parity of the mother. In conclusion, from the perspective of mothers, Swiss newborn infants prefer the taste of the oily vitamin D(3) preparation over the alcoholic preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Several factors facilitate or hinder efficacy research in occupational therapy. Strategies are needed, therefore, to support the successful implementation of trials. AIM To assess the feasibility of conducting a randomised controlled trial (RCT). The main feasibility objectives of this study were to assess the process, resources, management, and scientific basis of a trial RCT. MATERIAL AND METHODS A total of 10 occupational therapists, between the ages of 30 and 55 (M 43.4; SD 8.3) with seven to 26 years' (M 14.3; SD 6.1) experience, participated in this study. Qualitative data collected included minutes of meetings, reports, and field notes. The data were analysed based on the principles of content analysis, using feasibility objectives as the main categories. RESULTS Data analysis revealed strengths in relation to retention and inclusion criteria of participants, the study protocol, study organisation, and the competence of researchers. Weaknesses were found related to recruitment, randomisation, data collection, time for training and communication, commitment, and design. CONCLUSION The findings indicated that there are several factors which had a considerable impact on the implementation of an RCT in practice. However, it was useful to assess methods and procedures of the trial RCT as a basis to refine research plans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Light cure of resin-based adhesives is the mainstay of orthodontic bonding. In recent years, alternatives to conventional halogen lights offering reduced curing time and the potential for lower attachment failure rates have emerged. The relative merits of curing lights in current use, including halogen-based lamps, light-emitting diodes (LEDs), and plasma arc lights, have not been analyzed systematically. In this study, we reviewed randomized controlled trials and controlled clinical trials to assess the risks of attachment failure and bonding time in orthodontic patients in whom brackets were cured with halogen lights, LEDs, or plasma arc systems. METHODS Multiple electronic database searches were undertaken, including MEDLINE, EMBASE, and the Cochrane Oral Health Group's Trials Register, CENTRAL. Language restrictions were not applied. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, Pro-Quest Dissertation Abstracts, and Thesis database. Search terms included randomized controlled trial, controlled clinical trial, random allocation, double blind method, single blind method, orthodontics, LED, halogen, bond, and bracket. Authors of primary studies were contacted as required, and reference lists of the included studies were screened. RESULTS Randomized controlled trials and clinical controlled trials directly comparing conventional halogen lights, LEDs, or plasma arc systems involving patients with full arch, fixed, or bonded orthodontic appliances (not banded) with follow-up periods of a minimum of 6 months were included. Using predefined forms, 2 authors undertook independent extraction of articles; disagreements were resolved by discussion. The assessment of the risk of bias of the randomized controlled trials was based on the Cochrane Risk of Bias tool. Ten studies met the inclusion criteria; 2 were excluded because of high risk of bias. In the comparison of bond failure risk with halogen lights and plasma arc lights, 1851 brackets were included in both groups. Little statistical heterogeneity was observed in this analysis (I(2) = 4.8%; P = 0.379). There was no statistical difference in bond failure risk between the groups (OR, 0.92; 95% CI, 0.68-1.23; prediction intervals, 0.54, 1.56). Similarly, no statistical difference in bond failure risk was observed in the meta-analysis comparing halogen lights and LEDs (OR, 0.96; 95% CI, 0.64-1.44; prediction intervals, 0.07, 13.32). The pooled estimates from both comparisons were OR, 0.93; 95% CI, 0.74-1.17; and prediction intervals, 0.69, 1.17. CONCLUSIONS There is no evidence to support the use of 1 light cure type over another based on risk of attachment failure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Sedation is a cornerstone in the premedication for percutaneous coronary intervention (PCI). Benzodiazepines and opioids are frequently used. Previous results suggest that opioids mimic the adaptation to ischemia during repeated balloon inflations and may provide direct myocardial protection in addition to their sedative effect. However, no comparative data exist. METHODS: We conducted a prospective, randomized, controlled, single-blind trial comparing diazepam and fentanyl in 276 patients undergoing elective PCI. Patients were randomized to either diazepam 5 mg sublingually or fentanyl 0.05 mg or 0.1 mg intravenously at least 5 minutes prior to the first balloon inflation. The primary end-point was the postprocedural elevation of myocardial markers of necrosis defined as an elevation of cardiac troponin T > or = 0.01 ng/ml. RESULTS: The three groups had similar baseline clinical, angiographic, and procedural characteristics, with no significant differences in lesion morphology, procedural complexity, or adjunctive medical treatment. No significant variation in the hemodynamic response to the study drugs was observed in the three groups. The rate of postprocedural troponin T elevation was 28% in the diazepam group, 20% in the fentanyl 0.05 mg group, and 30% in the fentanyl 0.1 mg group (P = 0.26). Rates of postprocedural myocardial infarction were 3%, 2%, and 2%, respectively (P = 0.84), with one case of in-hospital death in the diazepam group and no urgent TVR in the whole study population. CONCLUSION: Although providing a well-tolerated alternative to diazepam for sedation during PCI, fentanyl did not provide additional cardioprotection assessed through the postinterventional elevation of cardiac troponin T during elective coronary intervention.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this single-blind randomized crossover study was to evaluate specific effects of manual acupuncture on central and vegetative nervous system activity measured by quantitative electroencephalography (qEEG) and heart rate variability (HRV). DESIGN: Twenty (20) healthy volunteers (mean: 25.2 +/- 3.6 years) were monitored simultaneously using a qEEG system and a 12-channel electrocardiogram recorder during verum acupuncture (VA) at acupuncture point Large Intestine 4 (Hegu) (LI4) or placebo acupuncture (PA) at a sham point. RESULTS: In the EEG conduction of the occipital area, needle stimulation in VA increased alpha1-frequency significantly, and the ratio alpha1/theta was shifted to the benefit of alpha1 over all electrodes. The HRV parameters showed a significant increase of the low frequency/high frequency (HF) ratio during the first minute of stimulation in VA, indicating an initial increase of sympathetic activation. However, an increase of HF power in the minute after stimulation followed by a decrease in heart rate suggests delayed vagal activation. De qi (a sensation that is typical of acupuncture needling) occurred in 16 subjects during VA and in 9 volunteers during PA (80% versus 45%). CONCLUSIONS: Manual stimulation on LI4 seems to lead to specific changes in alpha EEG-frequency and in HRV parameters. A linear relationship between the HRV parameters and the alpha EEG band might point to a specific modulation of cerebral function by vegetative effects during acupuncture.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: The aim of the present study was to test the effects of interdental cleansing with dental floss on supragingival biofilm removal in natural dentition during a 3-week period of experimental biofilm accumulation. MATERIALS AND METHODS: The present study was performed as a single-blind, parallel, randomised, controlled clinical trial using the experimental gingivitis model (Löe et al, 1965). Thirty-two students were recruited and assigned to one of the following experimental or control groups: Group A used a fluoride-containing dentifrice (NaF dentifrice) on a toothbrush for 60 s twice a day, Group B used an unwaxed dental floss twice a day, Group C used a waxed dental floss twice a day in every interproximal space and Group D rinsed twice a day for 60 s with drinking water (control). RESULTS: During 21 days of abolished oral hygiene, the groups developed various amounts of plaque and gingivitis. Neither of the cleansing protocols alone allowed the prevention of gingivitis development. Toothbrushing alone yielded better outcomes than did any of the flossing protocols. Interdental cleansing with a waxed floss had better biofilm removal effects than with unwaxed floss. CONCLUSIONS: Toothbrushing without interdental cleansing using dental floss and interdental cleansing alone cannot prevent the development of gingivitis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: A concentrate for bicarbonate haemodialysis acidified with citrate instead of acetate has been marketed in recent years. The small amount of citrate used (one-fifth of the concentration adopted in regional anticoagulation) protects against intradialyser clotting while minimally affecting the calcium concentration. The aim of this study was to compare the impact of citrate- and acetate-based dialysates on systemic haemodynamics, coagulation, acid-base status, calcium balance and dialysis efficiency. METHODS: In 25 patients who underwent a total of 375 dialysis sessions, an acetate dialysate (A) was compared with a citrate dialysate with (C+) or without (C) calcium supplementation (0.25 mmol/L) in a randomised single-blind cross-over study. Systemic haemodynamics were evaluated using pulse-wave analysis. Coagulation, acid-base status, calcium balance and dialysis efficiency were assessed using standard biochemical markers. RESULTS: Patients receiving the citrate dialysate had significantly lower systolic blood pressure (BP) (-4.3 mmHg, p < 0.01) and peripheral resistances (PR) (-51 dyne.sec.cm-5, p < 0.001) while stroke volume was not increased. In hypertensive patients there was a substantial reduction in BP (-7.8 mmHg, p < 0.01). With the C+ dialysate the BP gap was less pronounced but the reduction in PR was even greater (-226 dyne.sec.cm-5, p < 0.001). Analyses of the fluctuations in PR and of subjective tolerance suggested improved haemodynamic stability with the citrate dialysate. Furthermore, an increase in pre-dialysis bicarbonate and a decrease in pre-dialysis BUN, post-dialysis phosphate and ionised calcium were noted. Systemic coagulation activation was not influenced by citrate. CONCLUSION: The positive impact on dialysis efficiency, acid-base status and haemodynamics, as well as the subjective tolerance, together indicate that citrate dialysate can significantly contribute to improving haemodialysis in selected patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lacebacks may be used to limit unwanted incisor proclination during initial orthodontic alignment; however, their use has not met with universal approval. This systematic review aims to appraise the evidence in relation to the effectiveness of lacebacks in controlling incisor position during initial alignment. Electronic database searches of published literature (MEDLINE via Ovid, Cochrane Central Register of Controlled Trials, LILACS, and IBECS) and unpublished literature were performed. Search terms used included randomized controlled trial, controlled clinical trial, random allocation, double blind method, orthodontics, and laceback. Data were extracted using custom forms. Risk of bias assessment was made using the Cochrane Collaboration risk of bias tool. The quality of the evidence was also assessed using GRADE. Mean differences in incisor inclination and antero-posterior changes in incisor and molar position during alignment were calculated. Two studies involving 97 participants were found to be at low risk of bias and were included in the quantitative synthesis. The random effects meta-analysis demonstrated that the use of lacebacks was associated with 0.5 mm greater posterior movement of the incisors during alignment; this finding was of limited clinical importance and statistically non-significant [95 per cent confidence interval (CI): -1.25, 0.25, P = 0.19]. Little difference (0.46 mm) was also found between laceback and non-laceback groups with regards to mesial molar movement (95 per cent CI: -0.33, 1.24, P = 0.26). According to the GRADE assessment, the overall quality of evidence relating to the use of lacebacks was high. There is no evidence to support the use of lacebacks for the control of the sagittal position of the incisors during initial orthodontic alignment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One Hertz (1 Hz) repetitive transcranial magnetic stimulation (rTMS) is an effective therapy for auditory verbal hallucinations (AVH). Theta burst protocols (TBS) show longer after-effects. This single-blind, randomized controlled study compared continuous TBS with 1Hz rTMS in a 10-day treatment. Patients were diagnosed with schizophrenia or schizoaffective disorder. TBS demonstrated equal clinical effects compared to 1Hz TMS.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Depressive disorders are among the leading causes of worldwide disability with mild to moderate forms of depression being particularly common. Low-intensity treatments such as online psychological treatments may be an effective way to treat mild to moderate depressive symptoms and prevent the emergence or relapse of major depression. METHODS/DESIGN: This study is a currently recruiting multicentre parallel-groups pragmatic randomized-controlled single-blind trial. A total of 1000 participants with mild to moderate symptoms of depression from various settings including in- and outpatient services will be randomized to an online psychological treatment or care as usual (CAU). We hypothesize that the intervention will be superior to CAU in reducing depressive symptoms assessed with the Personal Health Questionnaire (PHQ-9, primary outcome measure) following the intervention (12 wks) and at follow-up (24 and 48 wks). Further outcome parameters include quality of life, use of health care resources and attitude towards online psychological treatments. DISCUSSION: The study will yield meaningful answers to the question of whether online psychological treatment can contribute to the effective and efficient prevention and treatment of mild to moderate depression on a population level with a low barrier to entry. TRIAL REGISTRATION: Trial Registration Number: NCT01636752.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Brushite and octacalcium phosphate (OCP) crystals are well-known precursors of hydroxylapatite (HAp), the main mineral found in bone. In this report, we present a new method for biomimicking brushite and OCP using single and double diffusion techniques. Brushite and OCP crystals were grown in an iota-carrageenan gel. The aggregates were analyzed by scanning electron microscopy (SEM), X-ray diffraction (XRD), infrared spectroscopy (IR) and thermal gravimetric analysis (TGA). SEM revealed different morphologies of brushite crystals from highly porous aggregates to plate-shaped forms. OCP crystals grown in iota-carrageenan showed a porous spherical shape different from brushite growth forms. The XRD method demonstrated that the single-diffusion method favors the formation of monoclinic brushite. In contrast, the double diffusion method was found to promote the formation of the triclinic octacalcium phosphate OCP phase. By combining the different parameters for crystal growth in carrageenan, such as ion concentration, gel pH and gel density, it is possible to modify the morphology of composite crystals, change the phase of calcium phosphate and modulate the amount of carrageenan inclusion in crystals. This study suggests that iota-carrageenan is a high-molecular-weight polysaccharide that is potentially applicable for controlling calcium phosphate crystallization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To develop and evaluate a method for ultrasound-guidance in performing the proximal paravertebral block for flank anaesthesia in cattle through a cadaveric study, followed by clinical application. STUDY DESIGN prospective experimental cadaveric study and clinical series. ANIMALS Previously frozen lumbar sections of cows without known spinal abnormalities were used. The clinical case group comprised of ten animals for which a right flank laparotomy was indicated. METHODS Twenty cow cadavers were used to perform ultrasound-guided bilateral injections of 1.0 mL dye (1.0 mL 1% Toluidine Blue in 1% Borax) at the intervertebral foramen at the level of T13, L1 and L2 spinal nerves. Distance and depth of injection, staining of the dorsal and ventral nerve branches, and deviation from the target were evaluated. The investigator's confidence as to visualisation and expected success at staining the nerve was assessed. Ten clinical cases received the ultrasound-guided proximal paravertebral anaesthesia. Analgesic success was evaluated using a 4-grade scoring system at 10 minutes after the injection and during surgery, respectively. Categorical variables were described using frequencies and proportions. RESULTS Both dorsal and ventral branches of the spinal nerves T13, L1 or L2 were at least partially stained in 41% of injections, while in 77% of injections one of the branches was stained. Five out of ten clinical cases had a satisfactory anaesthesia. There was no significant association between confidence at injection and either staining or analgesic success. CONCLUSION Results from the cadaveric and clinical study suggest no significant improvement using ultrasound guidance to perform proximal paravertebral block in cows compared to our previous clinical experience and to references in the literature using the blind method. CLINICAL RELEVANCE Further research should be conducted to improve the ultrasound-guided technique described in this study.