32 resultados para single electronic device

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

E-book reading devices open new possibilities in the field of reading. More activities than just reading a book can be performed with a single electronic device. For a long time, electronic reading devices have not been favored because their active LCD displays used to have a relatively low contrast. The new generation of electronic reading devices differs from earlier ones in the nature of the display: active LCD displays have been replaced with displays based on e-ink technology, which has display properties closer to that of printed paper. Moreover, e-ink technology has higher power efficiency, thereby increasing battery life and reducing weight. At first sight, the display looks similar to paper print, but the question remains whether the reading behavior also is equal to that of reading a printed book. In the present study, we analyzed and compared reading behavior on e-reader displays and on printed paper. The results suggest that the reading behavior on e-readers is indeed very similar to the reading behavior on print. Participants shared similar proportions of regressive saccades while reading on e-readers and print. Significant differences in fixation duration suggest that e-readers, in some situations, may even provide better legibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The goal of this randomized, open, controlled crossover manikin study was to compare the performance of "Animax", a manually operated hand-powered mechanical resuscitation device (MRD) to standard single rescuer basic life support (BLS).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The goal of this experimental study was to investigate rescuer exertion when using "Animax," a manually operated hand-powered mechanical resuscitation device (MRD) for cardiopulmonary resuscitation (CPR), compared to standard basic life support (BLS).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Several clinical studies on chronic stroke conducted with end-effector-based robots showed improvement of the motor function in the affected arm. Compared to end-effector-based robots, exoskeleton robots provide improved guidance of the human limb and are better suited to train task-oriented movements with a large range of motions. OBJECTIVE: To test whether intensive arm training with the arm exoskeleton ARMin I is feasible with chronic-stroke patients and whether it improves motor function in the paretic arm. METHODS: Three single cases with chronic hemiparesis resulting from unilateral stroke (at least 14 months after stroke). A-B design with 2 weeks of multiple baseline measurements (A), 8 weeks of training (B) with repetitive measurements and a follow-up measurement 8 weeks after training. The training included shoulder and elbow movements with the robotic rehabilitation device ARMin I. Two subjects had three 1-hour sessions per week and 1 subject received five 1-hour sessions per week. The main outcome measurement was the upper-limb part of the Fugl-Meyer Assessment (FMA). RESULTS: The ARMin training was well tolerated by the patients, and the FMA showed moderate, but significant improvements for all 3 subjects (p < 0.05). Most improvements were maintained 8 weeks after discharge. CONCLUSIONS: This study indicates that intensive training with an arm exoskeleton is feasible with chronic-stroke patients. Moderate improvements were found in all 3 subjects, thus further clinical investigations are justified.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The utility and inter-session repeatability of sensory threshold measurements using an electronic von Frey anesthesiometer (VFA) were assessed in a group of six neurologically normal dogs. Sensory threshold values obtained in neurologically normal dogs were compared to those of dogs with acute spinal cord injury (SCI) caused by intervertebral disc extrusion (n=6) and to a group of neurologically normal dogs with cranial cruciate ligament rupture (CCLR; n=6). Sensory threshold values in neurologically normal dogs were 155.8 ± 37.7 g and 154.7 ± 67.2 g for the left and right pelvic limbs, respectively. The difference in mean sensory threshold values obtained for the group when two distinct testing sessions were compared was not statistically significant (P>0.05). Mean sensory threshold values for the group with SCI were significantly higher than those for neurologically normal dogs at 351.1 ± 116.5 g and 420.3 ± 157.7 g for the left and right pelvic limbs, respectively (P=0.01). A comparison of sensory threshold values for the group with CCLR and neurologically normal dogs was not statistically significant (P>0.05). The modified dorsal technique for VFA described here represents a reliable method to assess sensory threshold in neurologically normal dogs and in those with SCI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Peri-implantitis is common in patients with dental implants. We performed a single-blinded longitudinal randomized study to assess the effects of mechanical debridement on the peri-implant microbiota in peri-implantitis lesions. MATERIALS AND METHODS: An expanded checkerboard DNA-DNA hybridization assay encompassing 79 different microorganisms was used to study bacterial counts before and during 6 months following mechanical treatment of peri-implantitis in 17 cases treated with curettes and 14 cases treated with an ultrasonic device. Statistics included non-parametric tests and GLM multivariate analysis with p<0001 indicating significance and 80% power. RESULTS: At selected implant test sites, the most prevalent bacteria were: Fusobacterium nucleatum sp., Staphylococci sp., Aggregatibacter actinomycetemcomitans, Helicobacter pylori, and Tannerella forsythia. 30 min. after treatment with curettes, A. actinomycetemcomitans (serotype a), Lactobacillus acidophilus, Streptococcus anginosus, and Veillonella parvula were found at lower counts (p<0.001). No such differences were found for implants treated with the ultrasonic device. Inconsistent changes occurred following the first week. No microbiological differences between baseline and 6-month samples were found for any species or between treatment study methods in peri-implantitis. CONCLUSIONS: Both methods failed to eliminate or reduce bacterial counts in peri-implantitis. No group differences were found in the ability to reduce the microbiota in peri-implantitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The data of 46 adults with single-sided sensorineural deafness who were candidates for bone-anchored hearing aids (Baha) CROS (contralateral routing of signals) were analyzed. All candidates tested a Baha with a headband in their normal environment. Subsequently, 29 of the candidates chose a permanent Baha CROS fitting, and 17 declined, thus forming the two study groups. No significant difference regarding age, sex or duration of deafness was found between the two groups. Similarly, the transcranial attenuation was not significantly different between those who accepted and declined a Baha. Subjects with some residual hearing in their poorer ear tended to decline a Baha, but the effect was not statistically significant. For a subset of 28 subjects, the Bern Benefit in Single-Sided Deafness questionnaire was administered. The questionnaire consists of 10 visual analogue scales rating the subjectively perceived benefit of the Baha or any other CROS device in different situations. Scores were found to be significantly higher for speech understanding at some distance (p = 0.026), for speech understanding in noise (p = 0.037), for group conversations (p < 0.01), and for the overall benefit (p < 0.01) for those candidates who chose to use a Baha as a CROS device permanently.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT) through the i-gel™ compared with the single-use ILMA™ (sILMA™) TT through the sILMA™ in patients with a predicted difficult airway.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acute BAO is a devastating neurological condition associated with a poor clinical outcome and a high mortality rate. Recanalization has been identified as a major prognostic factor for good outcome in BAO. Mechanical thrombectomy using retrievable stents is an emerging treatment option for acute stroke. First clinical trials using stent retrievers have shown promising high recanalization rates. However, these studies mainly included large artery occlusions in the anterior circulation with only a few or single cases of BAO. Therefore, the purpose of this study was to evaluate technical feasibility, safety, and efficacy of mechanical thrombectomy using retrievable stent in the treatment of acute BAO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a combined experimental and theoretical study of the electronic transport through single-molecule junctions based on nitrile-terminated biphenyl derivatives. Using a scanning tunneling microscope-based break-junction technique, we show that the nitrile-terminated compounds give rise to well-defined peaks in the conductance histograms resulting from the high selectivity of the N-Au binding. Ab initio calculations have revealed that the transport takes place through the tail of the LUMO. Furthermore, we have found both theoretically and experimentally that the conductance of the molecular junctions is roughly proportional to the square of the cosine of the torsion angle between the two benzene rings of the biphenyl core, which demonstrates the robustness of this structure-conductance relationship.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this systematic review was to assess the 5-year survival of implant-supported single crowns (SCs) and to describe the incidence of biological and technical complications. METHODS: An electronic MEDLINE search complemented by manual searching was conducted to identify prospective and retrospective cohort studies on SCs with a mean follow-up time of at least 5 years. Failure and complication rates were analyzed using random-effects Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS: Twenty-six studies from an initial yield of 3601 titles were finally selected and data were extracted. In a meta-analysis of these studies, survival of implants supporting SCs was 96.8% [95% confidence interval (CI): 95.9-97.6%] after 5 years. The survival rate of SCs supported by implants was 94.5% (95% CI: 92.5-95.9%) after 5 years of function. The survival rate of metal-ceramic crowns, 95.4% (95% CI: 93.6-96.7%), was significantly (P=0.005) higher than the survival rate, 91.2% (95% CI: 86.8-94.2%), of all-ceramic crowns. Peri-implantitis and soft tissue complications occurred adjacent to 9.7% of the SCs and 6.3% of the implants had bone loss exceeding 2 mm over the 5-year observation period. The cumulative incidence of implant fractures after 5 years was 0.14%. After 5 years, the cumulative incidence of screw or abutment loosening was 12.7% and 0.35% for screw or abutment fracture. For supra-structure-related complications, the cumulative incidence of ceramic or veneer fractures was 4.5%. CONCLUSION: It can be concluded that after an observation period of 5 years, high survival rates for implants and implant-supported SCs can be expected. However, biological and particularly technical complications are frequent.