4 resultados para self-deployment algorithms
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Costly on-site node repairs in wireless mesh networks (WMNs) can be required due to misconfiguration, corrupt software updates, or unavailability during updates. We propose ADAM as a novel management framework that guarantees accessibility of individual nodes in these situations. ADAM uses a decentralised distribution mechanism and self-healing mechanisms for safe configuration and software updates. In order to implement the ADAM management and self-healing mechanisms, an easy-to-learn and extendable build system for a small footprint embedded Linux distribution for WMNs has been developed. The paper presents the ADAM concept, the build system for the Linux distribution and the management architecture.
Resumo:
OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
Resumo:
Background: To detect attention deficit hyperactivity disorder (ADHD) in treatment seeking substance use disorders (SUD) patients, a valid screening instrument is needed. Objectives: To test the performance of the Adult ADHD Self-Report Scale V 1.1(ASRS) for adult ADHD in an international sample of treatment seeking SUD patients for DSM-IV-TR; for the proposed DSM-5 criteria; in different subpopulations, at intake and 1–2 weeks after intake; using different scoring algorithms; and different externalizing disorders as external criterion (including adult ADHD, bipolar disorder, antisocial and borderline personality disorder). Methods: In 1138 treatment seeking SUD subjects, ASRS performance was determined using diagnoses based on Conner's Adult ADHD Diagnostic Interview for DSM-IV (CAADID) as gold standard. Results: The prevalence of adult ADHD was 13.0% (95% CI: 11.0–15.0%). The overall positive predictive value (PPV) of the ASRS was 0.26 (95% CI: 0.22–0.30), the negative predictive value (NPV) was 0.97 (95% CI: 0.96–0.98). The sensitivity (0.84, 95% CI: 0.76–0.88) and specificity (0.66, 95% CI: 0.63–0.69) measured at admission were similar to the sensitivity (0.88, 95% CI: 0.83–0.93) and specificity (0.67, 95% CI: 0.64–0.70) measured 2 weeks after admission. Sensitivity was similar, but specificity was significantly better in patients with alcohol compared to (illicit) drugs as the primary substance of abuse (0.76 vs. 0.56). ASRS was not a good screener for externalizing disorders other than ADHD. Conclusions: The ASRS is a sensitive screener for identifying possible ADHD cases with very few missed cases among those screening negative in this population.
Resumo:
Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.