4 resultados para screener crusher

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: To detect attention deficit hyperactivity disorder (ADHD) in treatment seeking substance use disorders (SUD) patients, a valid screening instrument is needed. Objectives: To test the performance of the Adult ADHD Self-Report Scale V 1.1(ASRS) for adult ADHD in an international sample of treatment seeking SUD patients for DSM-IV-TR; for the proposed DSM-5 criteria; in different subpopulations, at intake and 1–2 weeks after intake; using different scoring algorithms; and different externalizing disorders as external criterion (including adult ADHD, bipolar disorder, antisocial and borderline personality disorder). Methods: In 1138 treatment seeking SUD subjects, ASRS performance was determined using diagnoses based on Conner's Adult ADHD Diagnostic Interview for DSM-IV (CAADID) as gold standard. Results: The prevalence of adult ADHD was 13.0% (95% CI: 11.0–15.0%). The overall positive predictive value (PPV) of the ASRS was 0.26 (95% CI: 0.22–0.30), the negative predictive value (NPV) was 0.97 (95% CI: 0.96–0.98). The sensitivity (0.84, 95% CI: 0.76–0.88) and specificity (0.66, 95% CI: 0.63–0.69) measured at admission were similar to the sensitivity (0.88, 95% CI: 0.83–0.93) and specificity (0.67, 95% CI: 0.64–0.70) measured 2 weeks after admission. Sensitivity was similar, but specificity was significantly better in patients with alcohol compared to (illicit) drugs as the primary substance of abuse (0.76 vs. 0.56). ASRS was not a good screener for externalizing disorders other than ADHD. Conclusions: The ASRS is a sensitive screener for identifying possible ADHD cases with very few missed cases among those screening negative in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the fact that bone mineral density (BMD) is an important fracture risk predictor in human medicine, studies in equine orthopedic research are still lacking. We hypothesized that BMD correlates with bone failure and fatigue fractures of this bone. Thus, the objectives of this study were to measure the structural and mechanical properties of the proximal phalanx with dual energy X-ray absorptiometry (DXA), to correlate the data obtained from DXA and computer tomography (CT) measurements to those obtained by loading pressure examination and to establish representative region of interest (ROI) for in vitro BMD measurements of the equine proximal phalanx for predicting bone failure force. DXA was used to measure the whole bone BMD and additional three ROI sites in 14 equine proximal phalanges. Following evaluation of the bone density, whole bone, cortical width and area in the mid-diaphyseal plane were measured on CT images. Bones were broken using a manually controlled universal bone crusher to measure bone failure force and reevaluated for the site of fractures on follow-up CT images. Compressive load was applied at a constant displacement rate of 2 mm/min until failure, defined as the first clear drop in the load measurement. The lowest BMD was measured at the trabecular region (mean +/- SD: 1.52 +/- 0.12 g/cm2; median: 1.48 g/cm2; range: 1.38-1.83 g/cm2). There was a significant positive linear correlation between trabelcular BMD and the breaking strength (P = 0.023, r = 0.62). The trabecular region of the proximal phalanx appears to be the only significant indicator of failure of strength in vitro. This finding should be reassessed to further reveal the prognostic value of trabecular BMD in an in vivo fracture risk model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To reliably determine the amplitude of the transmit radiofrequency ( B1+) field in moving organs like the liver and heart, where most current techniques are usually not feasible. METHODS B1+ field measurement based on the Bloch-Siegert shift induced by a pair of Fermi pulses in a double-triggered modified Point RESolved Spectroscopy (PRESS) sequence with motion-compensated crusher gradients has been developed. Performance of the sequence was tested in moving phantoms and in muscle, liver, and heart of six healthy volunteers each, using different arrangements of transmit/receive coils. RESULTS B1+ determination in a moving phantom was almost independent of type and amplitude of the motion and agreed well with theory. In vivo, repeated measurements led to very small coefficients of variance (CV) if the amplitude of the Fermi pulse was chosen above an appropriate level (CV in muscle 0.6%, liver 1.6%, heart 2.3% with moderate amplitude of the Fermi pulses and 1.2% with stronger Fermi pulses). CONCLUSION The proposed sequence shows a very robust determination of B1+ in a single voxel even under challenging conditions (transmission with a surface coil or measurements in the heart without breath-hold). Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.