7 resultados para retrieval time

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water vapour, despite being a minor constituent in the Martian atmosphere with its precipitable amount of less than 70 pr. μm, attracts considerable attention in the scientific community because of its potential importance for past life on Mars. The partial pressure of water vapour is highly variable because of its seasonal condensation onto the polar caps and exchange with a subsurface reservoir. It is also known to drive photochemical processes: photolysis of water produces H, OH, HO2 and some other odd hydrogen compounds, which in turn destroy ozone. Consequently, the abundance of water vapour is anti-correlated with ozone abundance. The Herschel Space Observatory provides for the first time the possibility to retrieve vertical water profiles in the Martian atmosphere. Herschel will contribute to this topic with its guaranteed-time key project called "Water and related chemistry in the solar system". Observations of Mars by Heterodyne Instrument for the Far Infrared (HIFI) and Photodetector Array Camera and Spectrometer (PACS) onboard Herschel are planned in the frame of the programme. HIFI with its high spectral resolution enables accurate observations of vertically resolved H2O and temperature profiles in the Martian atmosphere. Unlike HIFI, PACS is not capable of resolving the line-shape of molecular lines. However, our present study of PACS observations for the Martian atmosphere shows that the vertical sensitivity of the PACS observations can be improved by using multiple-line observations with different line opacities. We have investigated the possibility of retrieving vertical profiles of temperature and molecular abundances of minor species including H2O in the Martian atmosphere using PACS. In this paper, we report that PACS is able to provide water vapour vertical profiles for the Martian atmosphere and we present the expected spectra for future PACS observations. We also show that the spectral resolution does not allow the retrieval of several studied minor species, such as H2O2, HCl, NO, SO2, etc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies have shown both declining and stable semantic-memory abilities during healthy aging. There is consistent evidence that semantic processes involving controlled mechanisms weaken with age. In contrast, results of aging studies on automatic semantic retrieval are often inconsistent, probably due to methodological limitations and differences. The present study therefore examines age-related alterations in automatic semantic retrieval and memory structure with a novel combination of critical methodological factors, i.e., the selection of subjects, a well-designed paradigm, and electrophysiological methods that result in unambiguous signal markers. Healthy young and elderly participants performed lexical decisions on visually presented word/non-word pairs with a stimulus onset asynchrony (SOA) of 150 ms. Behavioral and electrophysiological data were measured, and the N400-LPC complex, an event-related potential component sensitive to lexical-semantic retrieval, was analyzed by power and topographic distribution of electrical brain activity. Both age groups exhibited semantic priming (SP) and concreteness effects in behavioral reaction time and the electrophysiological N400-LPC complex. Importantly, elderly subjects did not differ significantly from the young in their lexical decision and SP performances as well as in the N400-LPC SP effect. The only difference was an age-related delay measured in the N400-LPC microstate. This could be attributed to existing age effects in controlled functions, as further supported by the replicated age difference in word fluency. The present results add new behavioral and neurophysiological evidence to earlier findings, by showing that automatic semantic retrieval remains stable in global signal strength and topographic distribution during healthy aging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSES: To evaluate the safety of inferior vena cava (IVC) filter retrieval in therapeutically anticoagulated patients in comparison to prophylactically or not therapeutically anticoagulated patients with respect to retrieval-related hemorrhagic complications. MATERIALS AND METHODS: This was a retrospective study of 115 consecutive attempted IVC filter retrievals in 110 patients. Filter retrievals were stratified as performed in patients who were therapeutically anticoagulated (group 1), prophylactically anticoagulated (group 2), or not therapeutically anticoagulated (group 3). The collected data included anticoagulant and antiplatelet medications (type, form and duration of administration, dosage) at the time of retrieval. Phone interviews and chart review was performed for the international normalized ratio (INR), activated partial thromboplastin time, platelet count, infusion of blood products, and retrieval-related hemorrhagic complications. RESULTS: Group 1 included 65 attempted filter retrievals in 61 therapeutically anticoagulated patients by measured INR or dosing when receiving low-molecular-weight heparin (LMWH). Four retrievals were not successful. In patients receiving oral anticoagulation, the median INR was 2.35 (range, 2 to 8). Group 2 comprised 23 successful filter retrievals in 22 patients receiving a prophylactic dose of LMWH. Group 3 included 27 attempted filter retrievals in 27 patients not receiving therapeutic anticoagulation. Six retrievals were not successful. Five patients were receiving oral anticoagulation with a subtherapeutic INR (median, 1.49; range, 1.16 to 1.69). No anticoagulation medication was administered in 22 patients. In none of the groups were hemorrhagic complications related to the retrieval procedures identified. CONCLUSIONS: These results suggest that retrieval of vena cava filters in anticoagulated patients is safe. Interruption or reversal of anticoagulation for the retrieval of vena cava filters is not indicated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine the incidence of venous thromboembolism (VTE) after removal of retrievable inferior vena cava (IVC) filters. MATERIALS AND METHODS: Retrospective study was conducted of 67 patients who underwent 72 consecutive filter retrievals at a single institution. Data collected included VTE status at the time of filter placement, anticoagulant medications at the time of filter retrieval and afterward, new or recurrent VTE after filter removal, and insertion of subsequent filters. Patient questionnaires were completed in 50 cases, chart review in all patients. RESULTS: At the time of filter placement, 30 patients had documented VTE, 19 had a history of treated VTE, and 23 were at risk for but had neither previous nor present VTE. Mean duration of follow-up after filter removal was 20.6 months +/- 10.9. A total of 52 patients (57 filters) received anticoagulation and/or antiplatelet medications after filter removal. There were two documented episodes of recurrent deep vein thrombosis (2.8% of filters removed), both in patients who had VTE at the time of filter placement and underwent therapeutic anticoagulation at the time of filter removal. One of these patients (1.4% of filters removed) also experienced pulmonary embolism. Of the 23 patients without VTE when the filter was placed, none developed VTE after filter removal. Four patients (5.5% of filters removed) required subsequent permanent filters, three for complications of anticoagulation, one for failure of anticoagulation. CONCLUSIONS: VTE was rare after removal of IVC filters, but was most likely to occur in patients who had VTE at the time of filter placement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we describe agent-based content retrieval for opportunistic networks, where requesters can delegate content retrieval to agents, which retrieve the content on their behalf. The approach has been implemented in CCNx, the open source CCN framework, and evaluated on Android smart phones. Evaluations have shown that the overhead of agent delegation is only noticeable for very small content. For content larger than 4MB, agent-based content retrieval can even result in a throughput increase of 20% compared to standard CCN download applications. The requester asks every probe interval for agents that have retrieved the desired content. Evaluations have shown that a probe interval of 30s delivers the best overall performance in our scenario because the number of transmitted notification messages can be decreased by up to 80% without significantly increasing the download time.