42 resultados para respiratory mechanics
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND: The time course of impairment of respiratory mechanics and gas exchange in the acute respiratory distress syndrome (ARDS) remains poorly defined. We assessed the changes in respiratory mechanics and gas exchange during ARDS. We hypothesized that due to the changes in respiratory mechanics over time, ventilatory strategies based on rigid volume or pressure limits might fail to prevent overdistension throughout the disease process. METHODS: Seventeen severe ARDS patients {PaO2/FiO2 10.1 (9.2-14.3) kPa; 76 (69-107) mmHg [median (25th-75th percentiles)] and bilateral infiltrates} were studied during the acute, intermediate, and late stages of ARDS (at 1-3, 4-6 and 7 days after diagnosis). Severity of lung injury, gas exchange, and hemodynamics were assessed. Pressure-volume (PV) curves of the respiratory system were obtained, and upper and lower inflection points (UIP, LIP) and recruitment were estimated. RESULTS: (1) UIP decreased from early to established (intermediate and late) ARDS [30 (28-30) cmH2O, 27 (25-30) cmH2O and 25 (23-28) cmH2O (P=0.014)]; (2) oxygenation improved in survivors and in patients with non-pulmonary etiology in late ARDS, whereas all patients developed hypercapnia from early to established ARDS; and (3) dead-space ventilation and pulmonary shunt were larger in patients with pulmonary etiology during late ARDS. CONCLUSION: We found a decrease in UIP from acute to established ARDS. If applied to our data, the inspiratory pressure limit advocated by the ARDSnet (30 cmH2O) would produce ventilation over the UIP, with a consequent increased risk of overdistension in 12%, 43% and 65% of our patients during the acute, intermediate and late phases of ARDS, respectively. Lung protective strategies based on fixed tidal volume or pressure limits may thus not fully avoid the risk of lung overdistension throughout ARDS.
Resumo:
Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5-302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.
Resumo:
Many chronic human lung diseases have their origin in early childhood, yet most murine models used to study them utilize adult mice. An important component of the asthma phenotype is exaggerated airway responses, frequently modelled by methacholine (MCh) challenge. The present study was undertaken to characterize MCh responses in mice from 2 to 8 wk of age measuring absolute lung volume and volume-corrected respiratory mechanics as outcome variables. Female BALB/c mice aged 2, 3, 4, 6, and 8 wk were studied during cumulative intravenous MCh challenge. Following each MCh dose, absolute lung volume was measured plethysmographically at functional residual volume and during a slow inflation to 20-hPa transrespiratory pressure. Respiratory system impedance was measured continuously during the inflation maneuver and partitioned into airway and constant-phase parenchymal components by model fitting. Volume-corrected (specific) estimates of respiratory mechanics were calculated. Intravenous MCh challenge induced a predominantly airway response with no evidence of airway closure in any age group. No changes in functional residual volume were seen in mice of any age during the MCh challenge. The specific airway resistance MCh dose response curves did not show significant differences between the age groups. The results from the present study do not show systematic differences in MCh responsiveness in mice from 2 to 8 wk of age.
Resumo:
BACKGROUND: Morphological changes in preterm infants with bronchopulmonary dysplasia (BPD) have functional consequences on lung volume, ventilation inhomogeneity and respiratory mechanics. Although some studies have shown lower lung volumes and increased ventilation inhomogeneity in BPD infants, conflicting results exist possibly due to differences in sedation and measurement techniques. METHODOLOGY/PRINCIPAL FINDINGS: We studied 127 infants with BPD, 58 preterm infants without BPD and 239 healthy term-born infants, at a matched post-conceptional age of 44 weeks during quiet natural sleep according to ATS/ERS standards. Lung function parameters measured were functional residual capacity (FRC) and ventilation inhomogeneity by multiple breath washout as well as tidal breathing parameters. Preterm infants with BPD had only marginally lower FRC (21.4 mL/kg) than preterm infants without BPD (23.4 mL/kg) and term-born infants (22.6 mL/kg), though there was no trend with disease severity. They also showed higher respiratory rates and lower ratios of time to peak expiratory flow and expiratory time (t(PTEF)/t(E)) than healthy preterm and term controls. These changes were related to disease severity. No differences were found for ventilation inhomogeneity. CONCLUSIONS: Our results suggest that preterm infants with BPD have a high capacity to maintain functional lung volume during natural sleep. The alterations in breathing pattern with disease severity may reflect presence of adaptive mechanisms to cope with the disease process.
Resumo:
Infants with chronic lung disease (CLD) have a capacity to maintain functional lung volume despite alterations to their lung mechanics. We hypothesize that they achieve this by altering breathing patterns and dynamic elevation of lung volume, leading to differences in the relationship between respiratory muscle activity, flow and lung volume. Lung function and transcutaneous electromyography of the respiratory muscles (rEMG) were measured in 20 infants with CLD and in 39 healthy age-matched controls during quiet sleep. We compared coefficient of variations (CVs) of rEMG and the temporal relationship of rEMG variables, to flow and lung volume [functional residual capacity (FRC)] between these groups. The time between the start of inspiratory muscle activity and the resulting flow (tria)--in relation to respiratory cycle time--was significantly longer in infants with CLD. Although FRC had similar associations with tria and postinspiratory activity (corrected for respiratory cycle time), the CV of the diaphragmatic rEMG was lower in CLD infants (22.6 versus 31.0%, p = 0.030). The temporal relationship of rEMG to flow and FRC and the loss of adaptive variability provide additional information on coping mechanisms in infants with CLD. This technique could be used for noninvasive bedside monitoring of CLD.
Resumo:
High-frequency respiratory impedance data measured noninvasively by the high-speed interrupter technique (HIT), particularly the first antiresonance frequency (f(ar,1)), is related to airway wall mechanics. The aim of this study was to evaluate the feasibility and repeatability of HIT in unsedated pre-term infants, and to compare values of f(ar,1) from 18 pre-term (post-conceptional age 32-37 weeks, weight 1,730-2,910 g) and 18 full-term infants (42-47 weeks, 3,920-5,340 g). Among the pre-term infants, there was good short-term repeatability of f(ar,1) within a single sleep epoch (mean (sd) coefficient of variance: 8 (1.7)%), but 95% limits of agreement for repeated measures of f(ar,1) after 3-8 h were relatively wide (-41 Hz; 37 Hz). f(ar,1) was significantly lower in pre-term infants (199 versus 257 Hz), indicating that wave propagation characteristics in pre-term airways are different from those of full-term infants. The present authors suggest that this is consistent with developmental differences in airway wall structure and compliance, including the influence of the surrounding tissue. Since flow limitation is determined by wave propagation velocity and airway cross-sectional area, it was hypothesised that the physical ability of the airways to carry large flows is fundamentally different in pre-term than in full-term infants.
Resumo:
INTRODUCTION: It has been suggested that infants dynamically regulate their tidal flow and end-expiratory volume level. The interaction between muscle activity, flow and lung volume in spontaneously sleeping neonates is poorly studied, since it requires the assessment of transcutaneous electromyography of respiratory muscles (rEMG) in matched comparison to lung function measurements. METHODS: After determining feasibility and repeatability of rEMG in 20 spontaneously sleeping healthy neonates, we measured the relative impact of intercostal and diaphragmatic EMG activity in direct comparison to the resulting tidal flow and FRC. RESULTS: We found good feasibility, repeatability and correlation of timing indices between rEMG activity and flow. The rEMG amplitude was significantly dependent on the resistive load of the face mask. Diaphragm and intercostal muscle activity commenced prior to the onset of flow and remained active during the expiratory cycle. The relative contribution of intercostal and diaphragmatic activity to flow was variable and changed dynamically. CONCLUSION: Using matched rEMG, air flow and lung volume measurements, we have found good feasibility and repeatability of intercostal and diaphragm rEMG measurements and provide the first quantitative measures of the temporal relationship between muscle activity and flow in spontaneously sleeping healthy neonates. Lung mechanical function is dynamically regulated and adapts on a breath to breath basis. So, non-invasive rEMG measurements alone or in combination with lung function might provide a more comprehensive picture of pulmonary mechanics in future studies. The data describing the timing of EMG and flow may be important for future studies of EMG triggered mechanical ventilation.
Resumo:
Eight premature infants ventilated for hyaline membrane disease and enrolled in the OSIRIS surfactant trial were studied. Lung mechanics, gas exchange [PaCO2, arterial/alveolar PO2 ratio (a/A ratio)], and ventilator settings were determined 20 minutes before and 20 minutes after the end of Exosurf instillation, and subsequently at 12-24 hour intervals. Respiratory system compliance (Crs) and resistance (Rrs) were measured by means of the single breath occlusion method. After surfactant instillation there were no significant immediate changes in PaCO2 (36 vs. 37 mmHg), a/A ratio (0.23 vs. 0.20), Crs (0.32 vs. 0.31 mL/cm H2O/kg), and Rrs (0.11 vs. 0.16 cmH2O/mL/s) (pooled data of 18 measurement pairs). During the clinical course, mean a/A ratio improved significantly each time from 0.17 (time 0) to 0.29 (time 12-13 hours), to 0.39 (time 24-36 hours) and to 0.60 (time 48-61 hours), although mean airway pressure was reduced substantially. Mean Crs increased significantly from 0.28 mL/cmH2O/kg (time 0) to 0.38 (time 12-13 hours), to 0.37 (time 24-38 hours), and to 0.52 (time 48-61 hours), whereas mean Rrs increased from 0.10 cm H2O/mL/s (time 0) to 0.11 (time 12-13 hours), to 0.13 (time 24-36 hours) and to (time 48-61 hours) with no overall significance. A highly significant correlation was found between Crs and a/A ratio (r = 0.698, P less than 0.001). We conclude that Exosurf does not induce immediate changes in oxygenation as does the instillation of (modified) natural surfactant preparations. However, after 12 and 24 hours of treatment oxygenation and Crs improve significantly.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
Respiratory type-IV hypersensitivity reactions due to corticosteroids is a rare phenomenon. We describe two such cases. The first is a 37- year-old atopic woman who developed labial angioedema and nasal itching after the use of budesonide nasal spray. A month later, after the first puffs of a formoterol/budesonide spray prescribed for asthma, she noticed symptoms of tongue and oropharyngeal itching and redness with subsequent dysphagia, labial and tongue angioedema, and facial oedema. The second is a 15-year-old non-atopic woman who reported pruritic eruptions around the nostrils after using a budesonide nasal spray. A year later she presented with nasal pruritus with intense congestion and labial and facial oedema after using the same spray. Both patients were evaluated with patch-tests using the commercial T.R.U.E. test, a budesonide solution, and corticosteroid creams. Test evaluation was performed at 48 and 96 hours. In both patients, patch tests were positive to budesonide (++) on the second day. The first patient also had a positive (+) reaction to tixocortol-21-pivalate. All the other patch tests were negative. Clinicians should be aware that hypersensitivity reactions may occur during the use of nasal or inhaled corticosteroids.
Resumo:
BACKGROUND: Polymerase chain reaction (PCR) is a sensitive tool for detection of respiratory picornaviruses. However, the clinical relevance of picornavirus detection by PCR is unclear. Immunofluorescence (IF), widely used to detect other respiratory viruses, has recently been introduced as a promising detection method for respiratory picornaviruses. OBJECTIVES: To compare the clinical manifestations of respiratory picornavirus infections detected by IF with those of respiratory picornavirus infections detected by xTAG multiplex PCR in hospitalized children. STUDY DESIGN: During a 1-year period, nasopharyngeal aspirates (NPA) from all children hospitalized due to an acute respiratory infection were prospectively analyzed by IF. All respiratory picornavirus positive IF samples and 100 IF negative samples were further tested with xTAG multiplex PCR. After exclusion of children with co-morbidities and viral co-infections, monoinfections with respiratory picornaviruses were detected in 108 NPA of 108 otherwise healthy children by IF and/or PCR. We compared group 1 children (IF and PCR positive, n=84) with group 2 children (IF negative and PCR positive, n=24) with regard to clinical manifestations of the infection. RESULTS: Wheezy bronchitis was diagnosed more often in group 1 than in group 2 (71% vs. 46%, p=0.028). In contrast, group 2 patients were diagnosed more frequently with pneumonia (17% vs. 6%, p=0.014) accompanied by higher levels of C-reactive protein (46mg/l vs. 11mg/l, p=0.009). CONCLUSIONS: Picornavirus detection by IF in children with acute respiratory infection is associated with the clinical presentation of wheezy bronchitis. The finding of a more frequent diagnosis of pneumonia in picornavirus PCR positive but IF negative children warrants further investigation.
Resumo:
Curcumin exerts its anti-inflammatory activity via inhibition of nuclear factor κB. Oropharyngeal epithelia and residing bacteria closely interact in inflammation and infection. This in vitro model investigated the effects of curcumin on bacterial survival, adherence to, and invasion of upper respiratory tract epithelia, and studied its anti-inflammatory effect. We aimed to establish a model, which could offer insights into the host-pathogen interaction in cancer therapy induced mucositis.
Resumo:
Neuromuscular abnormalities are common in ICU patients. We aimed to assess the incidence of clinically diagnosed ICU-acquired paresis (ICUAP) and its impact on outcome.
Resumo:
The past decade has seen significant increases in combustion-generated ambient particles, which contain a nanosized fraction (less than 100 nm), and even greater increases have occurred in engineered nanoparticles (NPs) propelled by the booming nanotechnology industry. Although inhalation of these particulates has become a public health concern, human health effects and mechanisms of action for NPs are not well understood. Focusing on the human airway smooth muscle cell, here we show that the cellular mechanical function is altered by particulate exposure in a manner that is dependent upon particle material, size and dose. We used Alamar Blue assay to measure cell viability and optical magnetic twisting cytometry to measure cell stiffness and agonist-induced contractility. The eight particle species fell into four categories, based on their respective effect on cell viability and on mechanical function. Cell viability was impaired and cell contractility was decreased by (i) zinc oxide (40-100 nm and less than 44 microm) and copper(II) oxide (less than 50 nm); cell contractility was decreased by (ii) fluorescent polystyrene spheres (40 nm), increased by (iii) welding fumes and unchanged by (iv) diesel exhaust particles, titanium dioxide (25 nm) and copper(II) oxide (less than 5 microm), although in none of these cases was cell viability impaired. Treatment with hydrogen peroxide up to 500 microM did not alter viability or cell mechanics, suggesting that the particle effects are unlikely to be mediated by particle-generated reactive oxygen species. Our results highlight the susceptibility of cellular mechanical function to particulate exposures and suggest that direct exposure of the airway smooth muscle cells to particulates may initiate or aggravate respiratory diseases.
Resumo:
This case series reports the correlation between extravascular lung water (EVLW) and the partial arterial oxygen pressure/fractional inspiratory oxygen (PaO(2)/FiO(2)) ratio in three patients with severe influenza A (H1N1)-induced respiratory failure. All patients suffered from grave hypoxia (PaO(2), 26-42 mmHg) and were mechanically ventilated using biphasic airway pressure (PEEP, 12-15 mmHg; FiO(2), 0.8-1) in combination with prone positioning at 12 hourly intervals. All patients were monitored using the PICCO system for 8-11 days. During mechanical ventilation, a total of 62 simultaneous determinations of the PaO(2)/FiO(2) ratio and EVLW were performed. A significant correlation between EVLW and the PaO(2)/FiO(2) ratio (Spearman-rho correlation coefficient, -0.852; p < 0.001) was observed. In all patients, a decrease in EVLW was accompanied by an improvement in oxygenation. Serum lactate dehydrogenase levels were elevated in all patients and significantly correlated with EVLW during the intensive care unit stay (Spearman-rho correlation coefficient, 0.786; p < 0.001). In conclusion, EVLW seems increased in patients with severe H1N1-induced respiratory failure and appears to be closely correlated with impairments of oxygenatory function.