14 resultados para relief
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To test the comparative effectiveness of 2 nonpharmacologic pain-relieving interventions administered alone or in combination across time for repeated heel sticks in preterm infants.
Resumo:
BACKGROUND: In Switzerland approximately 8% of infants are born prematurely. Some of them undergo mechanical ventilation including endotracheal suctioning (ETS). ETS is one of the most frequently performed interventions and is linked to stress and pain, but its treatment is controversial. In Switzerland there is a lack of standardisation in pain relief for ETS. AIMS: To test the hypothesis that an intermittent dose of morphine reduces pain during ETS and that subsequent multisensorial stimulation (MSS), as a non pharmacological comforting intervention, helps infants to recover from experienced pain. METHOD: A randomized placebo controlled trial in two tertiary neonatal intensive care units (NICU) with a sample of 30 mechanically ventilated preterm infants was conducted. Pain was measured by three pain assessment tools (Bernese Pain Scale for Neonates, Premature Infant Pain Profile and Visual Analogue Scale) RESULTS: Morphine did not lead to any pain relief from ETS as measured by three pain scales. Nor did the comforting intervention of MSS show any effect. Repeated-measure analysis of variance for the within and between groups comparison showed no statistical significance. CONCLUSIONS: The administration of morphine for pain relief in ventilated preterm neonates during ETS remains questionable and the use of MSS as a comforting intervention after painful stimulus cannot be recommended. The validity testing of the instruments for this patient population should undergo a systematic validation trajectory. Future research should focus on options among non pharmacological interventions for relieving pain during ETS.
Resumo:
Purpose The effectiveness of vertebral augmentation techniques is a currently highly debated issue. The biomechanical literature suggests that cement filling volumes may play an important role in the ‘‘dosage’’ of vertebral augmentation and its pain alleviating effect. Good clinical data about filling volumes are scarce and most patient series are small. Therefore, we investigated the predictors of pain alleviation after balloon kyphoplasty in the nationwide SWISSspine registry where cement volumes are also recorded. Methods All single-level vertebral fractures with no additional fracture stabilization and availability of at least one follow-up within 6 months after surgery were included. The following potential predictors were assessed in a multivariate logistic regression model with the group’s average pain alleviation of 41 points on VAS as the desired outcome: patient age, patient sex, diagnosis, preoperative pain, level of fracture, type of fracture, age of fracture, segmental kyphotic deformity, cement volume, vertebral body filling volume, and cement extrusions. Results There were 194 female and 82 males with an average age of 70.4 and 65.3 years, respectively. Female patients were about twice as likely for achieving the average pain relief compared to males (p = 0.04). The preoperative pain level was the strongest predictor in that the likelihood for achieving an at least 41-point pain relief increased by about 8 % with each additional point of preoperative pain (p\0.001). A thoraco-lumbar fracture had a three times higher odds for the average pain relief compared with a lumbar fracture (p = 0.03). An A.3.1 fracture only had about a third of the probability for average pain relief compared with an A.1.1 fracture (p = 0.004). Cement volumes up to 4.5 ml only had an approximately 40 % chance for a minimum 41-point pain alleviation as compared with cement volumes of at least 4.5 ml (p = 0.007). In addition, the relationship between cement volume and pain alleviation followed a dose-dependent pattern. Conclusions Cement volume was revealed as a significant predictor for pain relief in BKP. Cement volume was the third most important influential covariate and the most important modifiable and operator dependent one. The clear dose-outcome relationship between cement filling volumes and pain relief additionally supports these findings. Cement volumes of [4.5 ml seem to be recommendable for achieving relevant pain alleviation. Patient sex and fracture type and location were further significant predictors and all these covariates should be recorded and reported in future studies about the pain alleviating effectiveness of vertebral augmentation procedures.
Resumo:
In a multicenter, randomized, controlled, open-label, parallel- group trial hyaluronic acid vaginal gel (Hyalofemme) was compared to estriol vaginal cream (Ovestin) in women with vaginal dryness due to various causes. A total of 144 supposedly postmenopausal women below age 70 years were randomized in a 1:1 ratio to either receive hyaluronic acid vaginal gel (5 g per application) or estriol vaginal cream (0.5 g cream per application = 0.5 mg estriol) every 3 days for a total of ten applications, respectively. Exclusion criteria included vaginal infections, conventional contraindications to estrogens, use of vaginal products other than the investigational compounds, being unmarried, pregnant, or breastfeeding. The aim of the study was to test for non-inferiority of hyaluronic acid vaginal gel compared to estriol vaginal cream. The primary efficacy end point was the percentage (%) improvement in vaginal dryness, with the secondary end points being the percentage (%) improvements in vaginal itching, burning, and dyspareunia. Efficacy was assessed by using a visual analog scale (VAS) (0-10; 0 = absent, 10 = intolerable) at baseline (V0), during telephone contact after the third administration (V1), and at the final visit after the tenth administration (V2). Safety parameters included vaginal pH, endometrial thickness, and a vaginal smear for vaginal microecosystem assessment. Adverse events were recorded according to international guidelines. 133 women completed the study. At baseline, participants' characteristics did not differ significantly. Mean age was 54 years, time since menopause was 5 years on average, and cause of menopause was mostly natural. However, mean menstrual cycle days were also reported, although according to inclusion criteria only postmenopausal women were eligible for the study. At V1, an improvement in vaginal dryness was reported by about 49 % of women using hyaluronic acid vaginal gel, and by 53 % of women using estriol vaginal cream (p = 0.31). At V2, the percentage improvement rates were 84 and 89 % (p = 0.13), respectively. Improvement rates for vaginal itching, burning, and dyspareunia at V2 were about 86, 85, and 57 % for hyaluronic acid vaginal gel, and 82, 87, and 62 % for estriol vaginal cream (p[0.05), respectively. After treatment, vaginal pH was significantly lower in estriol-treated women compared to those having received hyaluronic acid. Endometrial thickness did not differ between groups. In the majority of women, the vaginal microenvironment remained unaffected by treatment. However, the proportion of women whose abnormal vaginal microecological results became normal was higher in women using estriol vaginal cream. Adverse events (suspected to be) related to the investigational compounds were minor and included vaginal infection and genital itching. The authors concluded that hyaluronic acid vaginal gel was not inferior to estriol vaginal cream in women presenting with vaginal dryness. They suggest using hyaluronic acid vaginal gel not only as an alternative treatment to vaginal estrogens, but also to consider its general use in women presenting with vaginal dryness of any cause.
Resumo:
BACKGROUND Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. METHODS A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. RESULTS In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. CONCLUSION The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection.
Resumo:
Le relief accidenté, le climat agressif favorisé par l’Alizé, ainsi que l’étroite dépendance de la population de l’exploitation forestière et de l’exploitation agricole sans dispositifs de protection antiérosifs, sont les contextes qui permettent de dire que la région de Mandraka est sujette au problème d’érosion. L’étude a pour objectif de déterminer les relations entre les caractéristiques du sol, son mode d’occupation, les précipitations ainsi que l’érosion dans la région de Mandraka et ce en vue d’un aménagement rationnel. Des dispositifs pour la mesure de pertes en terre et de ruissellement ont été matérialisés sur des parcelles d’expérimentation. A cet effet, le choix de ces parcelles a porté sur le mode d’occupation du sol (sous terrains aménagés, sous « tavy », sous « savoka », et sous forêt naturelle), sur la similitude des pentes et sur leur localisation de manière à ce qu’elles soient situées sur les mi-versants. Les résultats ont montré que le sol dans cette région contient un taux de matière organique satisfaisant à élevé (2,41 à 3,74% de MO), lui permettant une bonne stabilité structurale (Is = 0,85 et K = 0,08). Les pertes en terre (0,13 à 20,93t/ha/an) et les ruissellements (0,3 à 5%) obtenus indiquent que l’érosion est faible à accélérée suivant le mode d’occupation du sol. En deux ans d’aménagement, les terrasses se sont stabilisées et les racines de Vetiveria zizanoides peuvent remplacer les fascines initialement installées pour tenir les talus. Toutefois, l’exposition du sol à la battance de la pluie et la mauvaise infiltration d’eau de ruissellement dans le sol accélèrent le phénomène d’érosion. Par ailleurs, il y a l’efficacité de la SCV sans brûlis bien qu’il s’agit de la première année d’expérience. Dans ces conditions, un plan d’aménagement simplifié a été proposé en vue (i) de protéger le sol contre la battance de la pluie, (ii) de réduire les transports solides par l’érosion et (iii) d’améliorer l’infiltration d’eau du sol.
Resumo:
BACKGROUND Delayed-onset muscle soreness (DOMS) is a common symptom in people participating in exercise, sport, or recreational physical activities. Several remedies have been proposed to prevent and alleviate DOMS. DESIGN AND METHODS A five-arm randomized controlled study was conducted to examine the effects of acupuncture on eccentric exercise-induced DOMS of the biceps brachii muscle. Participants were recruited through convenience sampling of students and general public. Participants were randomly allocated to needle, laser, sham needle, sham laser acupuncture, and no intervention. Outcome measures included pressure pain threshold (PPT), pain intensity (visual analog scale), and maximum isometric voluntary force. RESULTS Delayed-onset muscle soreness was induced in 60 participants (22 females, age 23.6 ± 2.8 years, weight 66.1 ± 9.6 kg, and height 171.6 ± 7.9 cm). Neither verum nor sham interventions significantly improved outcomes within 72 hours when compared with no treatment control (P > 0.05). CONCLUSIONS Acupuncture was not effective in the treatment of DOMS. From a mechanistic point of view, these results have implications for further studies: (1) considering the high-threshold mechanosensitive nociceptors of the muscle, the cutoff for PPT (5 kg/cm) chosen to avoid bruising might have led to ceiling effects; (2) the traditional acupuncture regimen, targeting muscle pain, might have been inappropriate as the DOMS mechanisms seem limited to the muscular unit and its innervation. Therefore, a regionally based regimen including an intensified intramuscular needling (dry needling) should be tested in future studies, using a higher cutoff for PPT to avoid ceiling effects.