6 resultados para reference models

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several practical obstacles in data handling and evaluation complicate the use of quantitative localized magnetic resonance spectroscopy (qMRS) in clinical routine MR examinations. To overcome these obstacles, a clinically feasible MR pulse sequence protocol based on standard available MR pulse sequences for qMRS has been implemented along with newly added functionalities to the free software package jMRUI-v5.0 to make qMRS attractive for clinical routine. This enables (a) easy and fast DICOM data transfer from the MR console and the qMRS-computer, (b) visualization of combined MR spectroscopy and imaging, (c) creation and network transfer of spectroscopy reports in DICOM format, (d) integration of advanced water reference models for absolute quantification, and (e) setup of databases containing normal metabolite concentrations of healthy subjects. To demonstrate the work-flow of qMRS using these implementations, databases for normal metabolite concentration in different regions of brain tissue were created using spectroscopic data acquired in 55 normal subjects (age range 6-61 years) using 1.5T and 3T MR systems, and illustrated in one clinical case of typical brain tumor (primitive neuroectodermal tumor). The MR pulse sequence protocol and newly implemented software functionalities facilitate the incorporation of qMRS and reference to normal value metabolite concentration data in daily clinical routine. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Currently, observations of space debris are primarily performed with ground-based sensors. These sensors have a detection limit at some centimetres diameter for objects in Low Earth Orbit (LEO) and at about two decimetres diameter for objects in Geostationary Orbit (GEO). The few space-based debris observations stem mainly from in-situ measurements and from the analysis of returned spacecraft surfaces. Both provide information about mostly sub-millimetre-sized debris particles. As a consequence the population of centimetre- and millimetre-sized debris objects remains poorly understood. The development, validation and improvement of debris reference models drive the need for measurements covering the whole diameter range. In 2003 the European Space Agency (ESA) initiated a study entitled “Space-Based Optical Observation of Space Debris”. The first tasks of the study were to define user requirements and to develop an observation strategy for a space-based instrument capable of observing uncatalogued millimetre-sized debris objects. Only passive optical observations were considered, focussing on mission concepts for the LEO, and GEO regions respectively. Starting from the requirements and the observation strategy, an instrument system architecture and an associated operations concept have been elaborated. The instrument system architecture covers the telescope, camera and onboard processing electronics. The proposed telescope is a folded Schmidt design, characterised by a 20 cm aperture and a large field of view of 6°. The camera design is based on the use of either a frame-transfer charge coupled device (CCD), or on a cooled hybrid sensor with fast read-out. A four megapixel sensor is foreseen. For the onboard processing, a scalable architecture has been selected. Performance simulations have been executed for the system as designed, focussing on the orbit determination of observed debris particles, and on the analysis of the object detection algorithms. In this paper we present some of the main results of the study. A short overview of the user requirements and observation strategy is given. The architectural design of the instrument is discussed, and the main tradeoffs are outlined. An insight into the results of the performance simulations is provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large number of studies utilize animal models to investigate therapeutic angiogenesis. However, the lack of a standardized experimental model leaves the comparison of different studies problematic. To establish a reference model of prolonged moderate tissue ischemia, we created unilateral hind limb ischemia in athymic rnu-rats by surgical excision of the femoral vessels. Blood flow of the limb was monitored for 60 days by laser Doppler imaging. Following a short postoperative period of substantially depressed perfusion, the animals showed a status of moderate hind limb ischemia from day 14 onwards. Thereafter, the perfusion remained at a constant level (55.5% of normal value) until the end of the observation period. Histopathological assessment of the ischemic musculature on postoperative days 28 and 60 showed essentially no inflammatory cell infiltrate or fibrosis. However, the mitochondrial activity and capillary-to-fiber ratio of the muscular tissue was reduced to 52.7% of normal, presenting with a significant weakness of the ischemic limb evidenced by a progressive decline in performance. Intramuscular injection of culture-expanded human endothelial progenitor cells (EPC) resulted in a significant increase in blood flow (82.0+/-3.5% of normal), capillary density (1.60+/-0.08/muscle fiber) and smooth muscle covered arterioles (8.0+/-0.6/high power field) in the ischemic hind limb as compared to controls (55.0+/-3.1%; 0.99+/-0.03; 5.0+/-0.2). In conclusion, chronic, moderate hind limb ischemia with consistently reduced perfusion levels persisting over a prolonged period can be established reliably in rnu athymic nude rats and is responsive to pro-angiogenic treatments such as EPC transplantation. This study provides a detailed protocol of a highly reproducible reference model to test novel therapeutic options for limb ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within the context of exoplanetary atmospheres, we present a comprehensive linear analysis of forced, damped, magnetized shallow water systems, exploring the effects of dimensionality, geometry (Cartesian, pseudo-spherical, and spherical), rotation, magnetic tension, and hydrodynamic and magnetic sources of friction. Across a broad range of conditions, we find that the key governing equation for atmospheres and quantum harmonic oscillators are identical, even when forcing (stellar irradiation), sources of friction (molecular viscosity, Rayleigh drag, and magnetic drag), and magnetic tension are included. The global atmospheric structure is largely controlled by a single key parameter that involves the Rossby and Prandtl numbers. This near-universality breaks down when either molecular viscosity or magnetic drag acts non-uniformly across latitude or a poloidal magnetic field is present, suggesting that these effects will introduce qualitative changes to the familiar chevron-shaped feature witnessed in simulations of atmospheric circulation. We also find that hydrodynamic and magnetic sources of friction have dissimilar phase signatures and affect the flow in fundamentally different ways, implying that using Rayleigh drag to mimic magnetic drag is inaccurate. We exhaustively lay down the theoretical formalism (dispersion relations, governing equations, and time-dependent wave solutions) for a broad suite of models. In all situations, we derive the steady state of an atmosphere, which is relevant to interpreting infrared phase and eclipse maps of exoplanetary atmospheres. We elucidate a pinching effect that confines the atmospheric structure to be near the equator. Our suite of analytical models may be used to develop decisively physical intuition and as a reference point for three-dimensional magnetohydrodynamic simulations of atmospheric circulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models generated from dental impressions (Digimodels; Orthoproof, Nieuwegein, The Netherlands). The Digimodels were used as the reference standard. METHODS The 3 types of digital models were made from 10 subjects. Four examiners repeated 37 linear tooth and arch measurements 10 times. Paired t tests and the intraclass correlation coefficient were performed to determine the reproducibility and accuracy of the measurements. RESULTS The CBCT images showed significantly smaller intraclass correlation coefficient values and larger duplicate measurement errors compared with the corresponding values for Digimodels and Anatomodels. The average difference between measurements on CBCT images and Digimodels ranged from -0.4 to 1.65 mm, with limits of agreement values up to 1.3 mm for crown-width measurements. The average difference between Anatomodels and Digimodels ranged from -0.42 to 0.84 mm with limits of agreement values up to 1.65 mm. CONCLUSIONS Statistically significant differences between measurements on Digimodels and Anatomodels, and between Digimodels and CBCT images, were found. Although the mean differences might be clinically acceptable, the random errors were relatively large compared with corresponding measurements reported in the literature for both Anatomodels and CBCT images, and might be clinically important. Therefore, with the CBCT settings used in this study, measurements made directly on CBCT images and Anatomodels are not as accurate as measurements on Digimodels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ratio of cystatin C (cysC) to creatinine (crea) is regarded as a marker of glomerular filtration quality associated with cardiovascular morbidities. We sought to determine reference intervals for serum cysC-crea ratio in seniors. Furthermore, we sought to determine whether other low-molecular weight molecules exhibit a similar behavior in individuals with altered glomerular filtration quality. Finally, we investigated associations with adverse outcomes. A total of 1382 subjectively healthy Swiss volunteers aged 60 years or older were enrolled in the study. Reference intervals were calculated according to Clinical & Laboratory Standards Institute (CLSI) guideline EP28-A3c. After a baseline exam, a 4-year follow-up survey recorded information about overall morbidity and mortality. The cysC-crea ratio (mean 0.0124 ± 0.0026 mg/μmol) was significantly higher in women and increased progressively with age. Other associated factors were hemoglobin A1c, mean arterial pressure, and C-reactive protein (P < 0.05 for all). Participants exhibiting shrunken pore syndrome had significantly higher ratios of 3.5-66.5 kDa molecules (brain natriuretic peptide, parathyroid hormone, β2-microglobulin, cystatin C, retinol-binding protein, thyroid-stimulating hormone, α1-acid glycoprotein, lipase, amylase, prealbumin, and albumin) and creatinine. There was no such difference in the ratios of very low-molecular weight molecules (urea, uric acid) to creatinine or in the ratios of molecules larger than 66.5 kDa (transferrin, haptoglobin) to creatinine. The cysC-crea ratio was significantly predictive of mortality and subjective overall morbidity at follow-up in logistic regression models adjusting for several factors. The cysC-crea ratio exhibits age- and sex-specific reference intervals in seniors. In conclusion, the cysC-crea ratio may indicate the relative retention of biologically active low-molecular weight compounds and can independently predict the risk for overall mortality and morbidity in the elderly.