20 resultados para quality-delivery mode

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone healing may be improved in implant patients by the administration of osteogenic agents, such as bone morphogenetic protein 2 (BMP-2). But the efficacy of BMP-2 depends upon its mode of application. We hypothesized that BMP-2 is capable of a higher osteogenic efficacy when delivered physiologically, viz., when incorporated into a calcium-phosphate carrier that mimics mineralized bone matrix, than when administered via simple pharmacological modes, such as by adsorption onto a carrier surface. Using an ectopic rat model, we compared the osteoinductive efficacies of calcium-phosphate implant-coatings bearing either incorporated, adsorbed, or incorporated and adsorbed BMP-2. When adsorbed directly onto the naked implant surface, BMP-2 was not osteogenic. When adsorbed onto a calcium-phosphate coating, it was osteoinductive, but not highly efficacious. When BMP-2 was incorporated into calcium-phosphate coatings, it was a potent bone-inducer, whose efficacy was compromised, not potentiated, by the additional deposition of an adsorbed pool.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The proliferation of multimedia content and the demand for new audio or video services have fostered the development of a new era based on multimedia information, which allowed the evolution of Wireless Multimedia Sensor Networks (WMSNs) and also Flying Ad-Hoc Networks (FANETs). In this way, live multimedia services require real-time video transmissions with a low frame loss rate, tolerable end-to-end delay, and jitter to support video dissemination with Quality of Experience (QoE) support. Hence, a key principle in a QoE-aware approach is the transmission of high priority frames (protect them) with a minimum packet loss ratio, as well as network overhead. Moreover, multimedia content must be transmitted from a given source to the destination via intermediate nodes with high reliability in a large scale scenario. The routing service must cope with dynamic topologies caused by node failure or mobility, as well as wireless channel changes, in order to continue to operate despite dynamic topologies during multimedia transmission. Finally, understanding user satisfaction on watching a video sequence is becoming a key requirement for delivery of multimedia content with QoE support. With this goal in mind, solutions involving multimedia transmissions must take into account the video characteristics to improve video quality delivery. The main research contributions of this thesis are driven by the research question how to provide multimedia distribution with high energy-efficiency, reliability, robustness, scalability, and QoE support over wireless ad hoc networks. The thesis addresses several problem domains with contributions on different layers of the communication stack. At the application layer, we introduce a QoE-aware packet redundancy mechanism to reduce the impact of the unreliable and lossy nature of wireless environment to disseminate live multimedia content. At the network layer, we introduce two routing protocols, namely video-aware Multi-hop and multi-path hierarchical routing protocol for Efficient VIdeo transmission for static WMSN scenarios (MEVI), and cross-layer link quality and geographical-aware beaconless OR protocol for multimedia FANET scenarios (XLinGO). Both protocols enable multimedia dissemination with energy-efficiency, reliability and QoE support. This is achieved by combining multiple cross-layer metrics for routing decision in order to establish reliable routes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We investigated the inflammatory response to, and the osteoinductive efficacies of, four polymers (collagen, Ethisorb, PLGA and Polyactive) that bore either an adsorbed (fast-release kinetics) or a calcium-phosphate-coating-incorporated (slow-release kinetics) depot of BMP-2. Titanium-plate-supported discs of each polymer (n = 6 per group) were implanted at an ectopic (subcutaneous) ossification site in rats (n = 48). Five weeks later, they were retrieved for a histomorphometric analysis of the volumes of ectopic bone and foreign-body giant cells (a gauge of inflammatory reactivity), and the degree of polymer degradation. For each polymer, the osteoinductive efficacy of BMP-2 was higher when it was incorporated into a coating than when it was directly adsorbed onto the material. This mode of BMP-2 carriage was consistently associated with an attenuation of the inflammatory response. For coated materials, the volume density of foreign-body giant cells was inversely correlated with the volume density of bone (r(2) = 0.96), and the volume density of bone was directly proportional to the surface-area density of the polymer (r(2) = 0.97). Following coating degradation, other competitive factors, such as the biocompatibility and the biodegradability of the polymer itself, came into play.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Osteogenic agents, such as bone morphogenetic protein-2 (BMP-2), can stimulate the degradation as well as the formation of bone. Hence, they could impair the osteoconductivity of functionalized implant surfaces. We assessed the effects of BMP-2 and its mode of delivery on the osteoconductivity of dental implants with either a naked titanium surface or a calcium-phosphate-coated one. The naked titanium surface bore adsorbed BMP-2, whilst the coated one bore incorporated, adsorbed, or incorporated and adsorbed BMP-2. The implants were inserted into the maxillae of adult miniature pigs. The volume of bone deposited within a defined "osteoconductive" (peri-implant) space, and bone coverage of the implant surface delimiting this space, were estimated morphometrically 1-3 weeks later. After 3 weeks, the volume of bone deposited within the osteoconductive space was highest for coated and uncoated implants bearing no BMP-2, followed by coated implants bearing incorporated BMP-2; it was lowest for coated implants bearing only adsorbed BMP-2. Bone-interface coverage was highest for coated implants bearing no BMP-2, followed by coated implants bearing either incorporated, or incorporated and adsorbed BMP-2; it was lowest for uncoated implants bearing adsorbed BMP-2. Hence, the osteoconductivity of implant surfaces can be significantly modulated by BMP-2 and its mode of delivery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In autologous cell therapy, e.g. in melanocyte transplantation for vitiligo, a minimally invasive mode of transepidermal delivery of the isolated cells is of crucial importance to reduce potential side effects such as infections and scarring as well as to minimize the duration of sick leave.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the publication of the quality guideline ICH Q9 "Quality Risk Management" by the International Conference on Harmonization, risk management has already become a standard requirement during the life cycle of a pharmaceutical product. Failure mode and effect analysis (FMEA) is a powerful risk analysis tool that has been used for decades in mechanical and electrical industries. However, the adaptation of the FMEA methodology to biopharmaceutical processes brings about some difficulties. The proposal presented here is intended to serve as a brief but nevertheless comprehensive and detailed guideline on how to conduct a biopharmaceutical process FMEA. It includes a detailed 1-to-10-scale FMEA rating table for occurrence, severity, and detectability of failures that has been especially designed for typical biopharmaceutical processes. The application for such a biopharmaceutical process FMEA is widespread. It can be useful whenever a biopharmaceutical manufacturing process is developed or scaled-up, or when it is transferred to a different manufacturing site. It may also be conducted during substantial optimization of an existing process or the development of a second-generation process. According to their resulting risk ratings, process parameters can be ranked for importance and important variables for process development, characterization, or validation can be identified. LAY ABSTRACT: Health authorities around the world ask pharmaceutical companies to manage risk during development and manufacturing of pharmaceuticals. The so-called failure mode and effect analysis (FMEA) is an established risk analysis tool that has been used for decades in mechanical and electrical industries. However, the adaptation of the FMEA methodology to pharmaceutical processes that use modern biotechnology (biopharmaceutical processes) brings about some difficulties, because those biopharmaceutical processes differ from processes in mechanical and electrical industries. The proposal presented here explains how a biopharmaceutical process FMEA can be conducted. It includes a detailed 1-to-10-scale FMEA rating table for occurrence, severity, and detectability of failures that has been especially designed for typical biopharmaceutical processes. With the help of this guideline, different details of the manufacturing process can be ranked according to their potential risks, and this can help pharmaceutical companies to identify aspects with high potential risks and to react accordingly to improve the safety of medicines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surgical navigation has proven to be a minimally invasive procedure that enables precise surgical interventions with reduced exposure to irradiation for patient and personnel. Fluoroscopy-based modules have prevailed on the market. For certain operations of the pelvis computed tomography is necessary with its high imaging quality and considerably larger scan volume. To enable navigation in these cases, matching of the CT data set and the patient's real pelvic bone is essential. The common pair point-matching algorithm is complemented by the surface-matching algorithm to achieve an even higher overall precision of the system. For conventional surface matching with a solid pointer, the bone has to be exposed from soft tissue quite extensively, using a solid pointer. This conflicts with the claim of computer-assisted surgery to be minimally invasive. We integrated an A-mode ultrasonic pointer with the intention to perform extended surface matching on the pelvic bone noninvasively. Related to the conventional method, comparable and to some extent even improved precision conditions could be established.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper evaluates the performance of the most popular power saving mechanisms defined in the IEEE 802.11 standard, namely the Power Save Mode (Legacy-PSM) and the Unscheduled Automatic Power Save Delivery (U-APSD). The assessment comprises a detailed study concerning energy efficiency and capability to guarantee the required Quality of Service (QoS) for a certain application. The results, obtained in the OMNeT++ simulator, showed that U-APSD is more energy efficient than Legacy-PSM without compromising the end-to- end delay. Both U-APSD and Legacy-PSM revealed capability to guarantee the application QoS requirements in all the studied scenarios. However, unlike U-APSD, when Legacy-PSM is used in the presence of QoS demanding applications, all the stations connected to the network through the same access point will consume noticeable additional energy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless Mesh Networks (WMNs) are increasingly deployed to enable thousands of users to share, create, and access live video streaming with different characteristics and content, such as video surveillance and football matches. In this context, there is a need for new mechanisms for assessing the quality level of videos because operators are seeking to control their delivery process and optimize their network resources, while increasing the user’s satisfaction. However, the development of in-service and non-intrusive Quality of Experience assessment schemes for real-time Internet videos with different complexity and motion levels, Group of Picture lengths, and characteristics, remains a significant challenge. To address this issue, this article proposes a non-intrusive parametric real-time video quality estimator, called MultiQoE that correlates wireless networks’ impairments, videos’ characteristics, and users’ perception into a predicted Mean Opinion Score. An instance of MultiQoE was implemented in WMNs and performance evaluation results demonstrate the efficiency and accuracy of MultiQoE in predicting the user’s perception of live video streaming services when compared to subjective, objective, and well-known parametric solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Two patient-focused long-term research projects performed in the German outpatient psychotherapy system are focused on in this article. The TK (Techniker Krankenkasse) project is the first study to evaluate a quality assurance and feedback system with regard to its practical feasibility in German routine care. The other study (“Quality Assurance in Outpatient Psychotherapy in Bavaria”; QS-PSY-BAY) was designed to test a new approach for quality assurance in outpatient psychotherapy using electronic documentation of patient characteristics and outcome parameters. In addition this project provides the opportunity to analyze data on health-related costs for the patients undergoing outpatient psychotherapy. Method: Both projects and their results indicating high effect sizes are briefly described. Results: From the perspectives of the research teams, advisory boards and other stakeholders, the experiences with these projects are discussed focusing on obstacles, challenges, difficulties, and benefits in developing and implementing the studies. The triangle collaboration of therapists, researchers, and health insurance companies/health service institutions turned out to be fruitful in both studies. Conclusions: Despite some controversies between the partners the experiences indicate the importance of practiced-research collaborations to provide relevant information about the delivery of outpatient psychotherapy in the health system

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Satellite remote sensing provides a powerful instrument for mapping and monitoring traces of historical settlements and infrastructure, not only in distant areas and crisis regions. It helps archaeologists to embed their findings from field surveys into the broader context of the landscape. With the start of the TanDEM-X mission, spatially explicit 3D-information is available to researchers at an unprecedented resolution worldwide. We examined different experimental TanDEM-X digital elevation models (DEM) that were processed from two different imaging modes (Stripmap/High Resolution Spotlight) using the operational alternating bistatic acquisition mode. The quality and accuracy of the experimental DEM products was compared to other available DEM products and a high precision archaeological field survey. The results indicate the potential of TanDEM-X Stripmap (SM) data for mapping surface elements at regional scale. For the alluvial plain of Cilicia, a suspected palaeochannel could be reconstructed. At the local scale, DEM products from TanDEM-X High Resolution Spotlight (HS) mode were processed at 2 m spatial resolution using a merge of two monostatic/bistatic interferograms. The absolute and relative vertical accuracy of the outcome meet the specification of high resolution elevation data (HRE) standards from the National System for Geospatial Intelligence (NSG) at the HRE20 level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SP’s performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Methods SP trainers from all five Swiss medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised with the partners twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. Both, SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). FAIR_OSCE The list of items to assess the quality of the simulation by SPs was primarily developed and used to provide formative feedback to the SPs in order to help them to improve their performance. It was therefore named “Feedbackstruckture for the Assessment of Interactive Role play in Objective Structured Clinical Exams (FAIR_OSCE). It was also used to assess the quality of patient portrayal during the exam. The results were calculated for each of the five faculties individually. Formative evaluation was given to the five faculties with individual feedback without revealing results of other faculties other than overall results. Results High quality of patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. In example the rate of completely correct reaction in medical tests increased from 88% to 95%. 95% completely correct reactions together with 4% sufficient reactions add up to 99% of the reactions meeting the requirements of the exam. SP educators using the instrument reported an augmentation of SPs performance induced by the use of the instrument. Disadvantages mentioned were high concentration needed to explicitly observe all criteria and cumbersome handling of the paper-based forms. Conclusion We were able to document a very high quality of SP performance in our exam. The data also indicate that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed augmentation of performance. The development of an iPad based application for the form is planned to address the cumbersome handling of the paper.