13 resultados para quality tests

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rationale: To provide a better understanding of cognitive functioning, motor outcome, behavior and quality of life after childhood stroke and to study the relationship between variables expected to influence rehabilitation and outcome (age at stroke, time elapsed since stroke, lateralization, location and size of lesion). Methods: Children who suffered from stroke between birth and their eighteenth year of life underwent an assessment consisting of cognitive tests (WISC-III, WAIS-R, K-ABC, TAP, Rey-Figure, German Version of the CVLT) and questionnaires (Conner's Scales, KIDSCREEN). Results: Twenty-one patients after stroke in childhood (15 males, mean 11;11 years, SD 4;3, range 6;10-21;2) participated in the study. Mean Intelligence Quotients (IQ) were situated within the normal range (mean Full Scale IQ 96.5, range IQ 79-129). However, significantly more patients showed deficits in various cognitive domains than expected from a healthy population (Performance IQ p = .000; Digit Span p = .000, Arithmetic's p = .007, Divided Attention p = .028, Alertness p = .002). Verbal IQ was significantly better than Performance IQ in 13 of 17 patients, independent of the hemispheric side of lesion. Symptoms of ADHD occurred more often in the patients' sample than in a healthy population (learning difficulties/inattention p = .000; impulsivity/hyperactivity p = .006; psychosomatics p = .006). Certain aspects of quality of life were reduced (autonomy p = .003; parents' relation p = .003; social acceptance p = .037). Three patients had a right-sided hemiparesis, mean values of motor functions of the other patients were slightly impaired (sequential finger movements p = .000, hand alternation p = .001, foot tapping p = .043). In patients without hemiparesis, there was no relation between the lateralization of lesion and motor outcome. Lesion that occurred in the midst of childhood (5-10 years) led to better cognitive outcome than lesion in the very early (0-5 years) or late childhood (10-18 years). Other variables such as presence of seizure, elapsed time since stroke and size of lesion had a small to no impact on prognosis. Conclusion: Moderate cognitive and motor deficits, behavioral problems, and impairment in some aspects of quality of life frequently remain after stroke in childhood. Visuospatial functions are more often reduced than verbal functions, independent of the hemispheric side of lesion. This indicates a functional superiority of verbal skills compared to visuospatial skills in the process of recovery after brain injury. Compared to the cognitive outcome following stroke in adults, cognitive sequelae after childhood stroke do indicate neither the lateralization nor the location of the lesion focus. Age at stroke seems to be the only determining factor influencing cognitive outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To quickly localize defects, we want our attention to be focussed on relevant failing tests. We propose to improve defect localization by exploiting dependencies between tests, using a JUnit extension called JExample. In a case study, a monolithic white-box test suite for a complex algorithm is refactored into two traditional JUnit style tests and to JExample. Of the three refactorings, JExample reports five times fewer defect locations and slightly better performance (-8-12\%), while having similar maintenance characteristics. Compared to the original implementation, JExample greatly improves maintainability due the improved factorization following the accepted test quality guidelines. As such, JExample combines the benefits of test chains with test quality aspects of JUnit style testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, screening tests for monitoring the prevalence of transmissible spongiform encephalopathies specifically in sheep and goats became available. Although most countries require comprehensive test validation prior to approval, little is known about their performance under normal operating conditions. Switzerland was one of the first countries to implement 2 of these tests, an enzyme-linked immunosorbent assay (ELISA) and a Western blot, in a 1-year active surveillance program. Slaughtered animals (n = 32,777) were analyzed in either of the 2 tests with immunohistochemistry for confirmation of initial reactive results, and fallen stock samples (n = 3,193) were subjected to both screening tests and immunohistochemistry in parallel. Initial reactive and false-positive rates were recorded over time. Both tests revealed an excellent diagnostic specificity (>99.5%). However, initial reactive rates were elevated at the beginning of the program but dropped to levels below 1% with routine and enhanced staff training. Only those in the ELISA increased again in the second half of the program and correlated with the degree of tissue autolysis in the fallen stock samples. It is noteworthy that the Western blot missed 1 of the 3 atypical scrapie cases in the fallen stock, indicating potential differences in the diagnostic sensitivities between the 2 screening tests. However, an estimation of the diagnostic sensitivity for both tests on field samples remained difficult due to the low disease prevalence. Taken together, these results highlight the importance of staff training, sample quality, and interlaboratory comparison trials when such screening tests are implemented in the field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity but quite similar polymerization contraction. MOD cavities (n=30) were prepared in extracted premolars, restored and then subjected to thermocyclic and mechanical loading. Marginal quality of the restorations before and after loading was analyzed on epoxy replicas under a scanning electron microscope. The percentage of gap-free margins and occurrence of paramarginal fractures were registered. Modulus of elasticity and polymerization contraction were analyzed with parametric and margins with nonparametric ANOVA and post hoc Tukey HSD or Wilcoxon rank-sum tests, respectively. The number of paramarginal fractures was analyzed with exact Fisher tests (α=0.05). RESULTS Grandio demonstrated significantly more gap-free enamel margins than Charisma and Filtek Supreme XTE, before and after loading (p<0.01), whereas there was no difference between Charisma and Filtek Supreme XTE (p>0.05). No significant effect of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p<0.0001). More paramarginal enamel fractures were observed after loading in teeth restored with Grandio when compared to Charisma (p=0.008). CONCLUSIONS The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE The results from this study suggest that the marginal quality of restorations can be improved by the selection of a resin composite with modulus of elasticity close to that of dentine, although an increase in paramarginal enamel fractures can result as a consequence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To prospectively evaluate the psychometric properties of the Venous Insufficiency Epidemiological and Economic Study (VEINES-QOL/Sym) questionnaire, an instrument to measure disease-specific quality of life and symptoms in elderly patients with deep vein thrombosis (DVT), and to validate a German version of the questionnaire. METHODS In a prospective multicenter cohort study of patients aged ≥ 65 years with acute venous thromboembolism, we used standard psychometric tests and criteria to evaluate the reliability, validity, and responsiveness of the VEINES-QOL/Sym in patients with acute symptomatic DVT. We also performed an exploratory factor analysis. RESULTS Overall, 352 French- and German-speaking patients were enrolled (response rate of 87 %). Both language versions of the VEINES-QOL/Sym showed good acceptability (missing data, floor and ceiling effects), reliability (internal consistency, item-total and inter-item correlations), validity (convergent, discriminant, known-groups differences), and responsiveness to clinical change over time in elderly patients with DVT. The exploratory factor analysis of the VEINES-QOL/Sym suggested three underlying dimensions: limitations in daily activities, DVT-related symptoms, and psychological impact. CONCLUSIONS The VEINES-QOL/Sym questionnaire is a practical, reliable, valid, and responsive instrument to measure quality of life and symptoms in elderly patients with DVT and can be used with confidence in prospective studies to measure outcomes in such patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BackgroundThe PEmb-QoL is a validated 40-item questionnaire to quantify health-related quality of life in patients having experienced pulmonary embolism (PE). It covers six health dimensions: frequency of complaints, activities of daily living limitations, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we sought to prospectively validate the psychometric properties of a French version of the PEmb-QoL.MethodsWe performed a forward and backward translation of the English version of the PEmb-QoL into French. French-speaking consecutive adult patients with an acute, objectively confirmed PE admitted to the emergency department of a Swiss university hospital between 08/2009 and 09/2011 were recruited telephonically. We used standard psychometric tests and criteria to evaluate the acceptability, reliability, and validity of the French version of the PEmb-QoL. We also performed an exploratory factor analysis.ResultsOverall, 102 patients were enrolled in the study. The French version of the PEmb-QoL showed good reliability (internal consistency, item¿total and inter-item correlations), reproducibility (test-retest reliability), and validity (convergent, discriminant) in French-speaking patients with PE. The exploratory factor analysis suggested three underlying dimensions: limitations in daily activity (items 4b-m, 5a-d), symptoms (items 1a-h and 7), and emotional complaints (items 9a-f and j).ConclusionWe successfully validated the French version of the PEmb-QoL questionnaire in patients with PE. Our results show that the PEmb-QoL is a valuable tool for assessing health-related quality of life after PE in French-speaking patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SP’s performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Methods SP trainers from all five Swiss medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised with the partners twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. Both, SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). FAIR_OSCE The list of items to assess the quality of the simulation by SPs was primarily developed and used to provide formative feedback to the SPs in order to help them to improve their performance. It was therefore named “Feedbackstruckture for the Assessment of Interactive Role play in Objective Structured Clinical Exams (FAIR_OSCE). It was also used to assess the quality of patient portrayal during the exam. The results were calculated for each of the five faculties individually. Formative evaluation was given to the five faculties with individual feedback without revealing results of other faculties other than overall results. Results High quality of patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. In example the rate of completely correct reaction in medical tests increased from 88% to 95%. 95% completely correct reactions together with 4% sufficient reactions add up to 99% of the reactions meeting the requirements of the exam. SP educators using the instrument reported an augmentation of SPs performance induced by the use of the instrument. Disadvantages mentioned were high concentration needed to explicitly observe all criteria and cumbersome handling of the paper-based forms. Conclusion We were able to document a very high quality of SP performance in our exam. The data also indicate that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed augmentation of performance. The development of an iPad based application for the form is planned to address the cumbersome handling of the paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The Pulmonary Embolism Quality of Life questionnaire (PEmb-QoL) is a 40-item questionnaire to measure health-related quality of life in patients with pulmonary embolism. It covers six 6 dimensions: frequency of complaints, limitations in activities of daily living, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we prospectively validated a German version of the PEmb-QoL. METHODS A forward-backward translation of the English version of the PEmb-QoL into German was performed. German-speaking consecutive adult patients aged ≥18 years with an acute, objectively confirmed pulmonary embolism discharged from a Swiss university hospital (01/2011-06/2013) were recruited telephonically. Established psychometric tests and criteria were used to evaluate the acceptability, reliability, and validity of the German PEmb-QoL questionnaire. To assess the underlying dimensions, an exploratory factor analysis was performed. RESULTS Overall, 102 patients were enrolled in the study. The German version of the PEmb-QoL showed a good internal consistency (Cronbach's alpha ranging from 0.72 to 0.96), item-total (0.53-0.95) and inter-item correlations (>0.4), and test-retest reliability (intra-class correlation coefficients 0.59-0.89) for the dimension scores. A moderate correlation of the PEmb-QoL with SF-36 dimension and summary scores (0.21-0.83) indicated convergent validity, while low correlations of PEmb-QoL dimensions with clinical characteristics (-0.16-0.37) supported discriminant validity. The exploratory factor analysis suggested four underlying dimensions: limitations in daily activities, symptoms, work-related problems, and emotional complaints. CONCLUSION The German version of the PEmb-QoL questionnaire is a valid and reliable disease-specific measure for quality of life in patients with pulmonary embolism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Democracies come in all shapes and sizes. Which configuration of political institutions produces the highest democratic quality is a notorious debate. The lineup of contenders includes ‘consensus’, ‘Westminster’, and ‘centripetal’ democracy. A trend in the evaluation of the relationship between empirical patterns of democracy and its quality is that the multidimensional nature of both concepts is increasingly taken into account. This article tests the assertion that certain centripetal configurations of proportionality in party systems and government, and unitarism in the remaining state structure, might outperform all other alternatives both in terms of inclusiveness and effectiveness. Analyzing 33 democracies, the results of interactive regression models only partially support this claim. Proportional–unitary democracies have the best track record in terms of representation, but there are little differences in participation, transparency, and government capability compared with other models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Web surveys are becoming increasingly popular in survey research including stated preference surveys. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. This is the first study that tests whether the use of mobile devices, tablets or smartphones, affects survey characteristics and stated preferences in a web-based choice experiment. The web survey on expanding renewable energy production in Germany was carried out with 3182 respondents, of which 12% used a mobile device. Propensity score matching is used to account for selection bias in the use of mobile devices for survey completion. We find that mobile device users spent more time than desktop/laptop users to answer the survey. Yet, desktop/laptop users and mobile device users do not differ in acquiescence tendency as an indicator of extreme response patterns. For mobile device users only, we find a negative correlation between screen size and interview length and a positive correlation between screen size and acquiescence tendency. In the choice experiment data, we do not find significant differences in the tendency to choose the status quo option and scale between both subsamples. However, some of the estimates of implicit prices differ, albeit not in a unidirectional fashion. Model results for mobile device users indicate a U-shaped relationship between error variance and screen size. Together, the results suggest that using mobile devices is not detrimental to survey quality.