9 resultados para quality requirements

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Software architecture is the result of a design effort aimed at ensuring a certain set of quality attributes. As we show, quality requirements are commonly specified in practice but are rarely validated using automated techniques. In this paper we analyze and classify commonly specified quality requirements after interviewing professionals and running a survey. We report on tools used to validate those requirements and comment on the obstacles encountered by practitioners when performing such activity (e.g., insufficient tool-support; poor understanding of users needs). Finally we discuss opportunities for increasing the adoption of automated tools based on the information we collected during our study (e.g., using a business-readable notation for expressing quality requirements; increasing awareness by monitoring non-functional aspects of a system).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Magnetic iron oxide nanoparticles have found application as contrast agents for magnetic resonance imaging (MRI) and as switchable drug delivery vehicles. Their stabilization as colloidal carriers remains a challenge. The potential of poly(ethylene imine)-g-poly(ethylene glycol) (PEGPEI) as stabilizer for iron oxide (γ-Fe₂O₃) nanoparticles was studied in comparison to branched poly(ethylene imine) (PEI). Carrier systems consisting of γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were prepared and characterized regarding their physicochemical properties including magnetic resonance relaxometry. Colloidal stability of the formulations was tested in several media and cytotoxic effects in adenocarcinomic epithelial cells were investigated. Synthesized γ-Fe₂O₃ cores showed superparamagnetism and high degree of crystallinity. Diameters of polymer-coated nanoparticles γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were found to be 38.7 ± 1.0 nm and 40.4 ± 1.6 nm, respectively. No aggregation tendency was observable for γ-Fe₂O₃-PEGPEI over 12 h even in high ionic strength media. Furthermore, IC₅₀ values were significantly increased by more than 10-fold when compared to γ-Fe₂O₃-PEI. Formulations exhibited r₂ relaxivities of high numerical value, namely around 160 mM⁻¹ s⁻¹. In summary, novel carrier systems composed of γ-Fe₂O₃-PEGPEI meet key quality requirements rendering them promising for biomedical applications, e.g. as MRI contrast agents.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper evaluates whether the Swiss monitoring programme for foreign substances in animal products fulfils basic epidemiological quality requirements, and identifies possible sources of bias in the selection of samples. The sampling was analysed over a 4-year period (2002-05). The sampling frame in 37 participating abattoirs covered 51% of all slaughtered pigs, 73% of calves, 68% of beef and 36% of cows. The analysis revealed that some sub-populations as defined by the region of origin were statistically over-represented while others were under-represented. The programme that is in accordance with European Union requirements contained some relevant bias. Patterns of under-sampled regions characterized by management type differences were identified. This could lead to an underestimate of the number of contaminated animals within the programme. Although the current sampling was stratified and partially risk-based, its efficiency could be improved by adopting a more targeted approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study served to assure the quality of our catering, to locate problems, and to define further optimization measures at the Bern University Hospital. The main objective was to investigate whether the macronutrient and energy content of the hospital food complies with the nutritional value calculated from recipes as well as with the recommendations issued by the German Nutrition Society (DGE).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multicasting is an efficient mechanism for one to many data dissemination. Unfortunately, IP Multicasting is not widely available to end-users today, but Application Layer Multicast (ALM), such as Content Addressable Network, helps to overcome this limitation. Our OM-QoS framework offers Quality of Service support for ALMs. We evaluated OM-QoS applied to CAN and show that we can guarantee that all multicast paths support certain QoS requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND We describe the setup of a neonatal quality improvement tool and list which peer-reviewed requirements it fulfils and which it does not. We report on the so-far observed effects, how the units can identify quality improvement potential, and how they can measure the effect of changes made to improve quality. METHODS Application of a prospective longitudinal national cohort data collection that uses algorithms to ensure high data quality (i.e. checks for completeness, plausibility and reliability), and to perform data imaging (Plsek's p-charts and standardized mortality or morbidity ratio SMR charts). The collected data allows monitoring a study collective of very low birth-weight infants born from 2009 to 2011 by applying a quality cycle following the steps 'guideline - perform - falsify - reform'. RESULTS 2025 VLBW live-births from 2009 to 2011 representing 96.1% of all VLBW live-births in Switzerland display a similar mortality rate but better morbidity rates when compared to other networks. Data quality in general is high but subject to improvement in some units. Seven measurements display quality improvement potential in individual units. The methods used fulfil several international recommendations. CONCLUSIONS The Quality Cycle of the Swiss Neonatal Network is a helpful instrument to monitor and gradually help improve the quality of care in a region with high quality standards and low statistical discrimination capacity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SP’s performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Methods SP trainers from all five Swiss medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised with the partners twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. Both, SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). FAIR_OSCE The list of items to assess the quality of the simulation by SPs was primarily developed and used to provide formative feedback to the SPs in order to help them to improve their performance. It was therefore named “Feedbackstruckture for the Assessment of Interactive Role play in Objective Structured Clinical Exams (FAIR_OSCE). It was also used to assess the quality of patient portrayal during the exam. The results were calculated for each of the five faculties individually. Formative evaluation was given to the five faculties with individual feedback without revealing results of other faculties other than overall results. Results High quality of patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. In example the rate of completely correct reaction in medical tests increased from 88% to 95%. 95% completely correct reactions together with 4% sufficient reactions add up to 99% of the reactions meeting the requirements of the exam. SP educators using the instrument reported an augmentation of SPs performance induced by the use of the instrument. Disadvantages mentioned were high concentration needed to explicitly observe all criteria and cumbersome handling of the paper-based forms. Conclusion We were able to document a very high quality of SP performance in our exam. The data also indicate that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed augmentation of performance. The development of an iPad based application for the form is planned to address the cumbersome handling of the paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The widespread use of wireless enabled devices and the increasing capabilities of wireless technologies has promoted multimedia content access and sharing among users. However, the quality perceived by the users still depends on multiple factors such as video characteristics, device capabilities, and link quality. While video characteristics include the video time and spatial complexity as well as the coding complexity, one of the most important device characteristics is the battery lifetime. There is the need to assess how these aspects interact and how they impact the overall user satisfaction. This paper advances previous works by proposing and validating a flexible framework, named EViTEQ, to be applied in real testbeds to satisfy the requirements of performance assessment. EViTEQ is able to measure network interface energy consumption with high precision, while being completely technology independent and assessing the application level quality of experience. The results obtained in the testbed show the relevance of combined multi-criteria measurement approaches, leading to superior end-user satisfaction perception evaluation .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To compare isoflurane alone or in combination with systemic ketamine and lidocaine for general anaesthesia in horses. STUDY DESIGN Prospective, randomized, blinded clinical trial. ANIMALS Forty horses (ASA I-III) undergoing elective surgery. METHODS Horses were assigned to receive isoflurane anaesthesia alone (ISO) or with ketamine and lidocaine (LKI). After receiving romifidine, diazepam, and ketamine, the isoflurane end-tidal concentration was set at 1.3% and subsequently adjusted by the anaesthetist (unaware of treatments) to maintain a light plane of surgical anaesthesia. Animals in the LKI group received lidocaine (1.5 mg kg(-1) over 10 minutes, followed by 40 microg kg(-1) minute(-1)) and ketamine (60 microg kg(-1) minute(-1)), both reduced to 65% of the initial dose after 50 minutes, and stopped 15 minutes before the end of anaesthesia. Standard clinical cardiovascular and respiratory parameters were monitored. Recovery quality was scored from one (very good) to five (very poor). Differences between ISO and LKI groups were analysed with a two-sample t-test for parametric data or a Fischer's exact test for proportions (p < 0.05 for significance). Results are mean +/- SD. RESULTS Heart rate was lower (p = 0.001) for LKI (29 +/- 4) than for ISO (34 +/- 6). End-tidal concentrations of isoflurane (ISO: 1.57% +/- 0.22; LKI: 0.97% +/- 0.33), the number of horses requiring thiopental (ISO: 10; LKI: 2) or dobutamine (ISO:8; LKI:3), and dobutamine infusion rates (ISO:0.26 +/- 0.09; LKI:0.18 +/- 0.06 microg kg(-1) minute(-1)) were significantly lower in LKI compared to the ISO group (p < 0.001). No other significant differences were found, including recovery scores. CONCLUSIONS AND CLINICAL RELEVANCE These results support the use of lidocaine and ketamine to improve anaesthetic and cardiovascular stability during isoflurane anaesthesia lasting up to 2 hours in mechanically ventilated horses, with comparable quality of recovery.